Matthew B. Applegate

Matthew B. Applegate

Auto-generated profile, based on publicly available information

Matthew B. Applegate

Boston Univ

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2020 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
MAMatthew B. Applegate
Matthew B. Applegate
KKKavon Karrobi
Kavon Karrobi
JAJoseph P. Angelo
Joseph P. Angelo
WAWyatt M. Austin
Wyatt M. Austin
STSyeda M. Tabassum
Syeda M. Tabassum
DRDarren M. Roblyer
Darren M. Roblyer
Spatial frequency domain imaging (SFDI) is a noninvasive, label-free, diffuse optical technique that can generate two-dimensional maps of the absorption coefficient (μa) and reduced scattering coefficient (μs′) of biological tissue. To accomplish this, SFDI utilizes sinusoidally modulated illumination patterns, which are projected onto the sample, and the remitted light is detected with a camera. A demodulation and calibration procedure is used to estimate the spatial modulation transfer function (MTF) of the sample. The MTF can then be fit to a computational model of photon transport to determine both μa and μs′ on a pixel-by-pixel basis.1 Knowledge of μa at several different carefully chosen wavelengths allows for the molar concentration of tissue chromophores such as oxyhemoglobin and deoxyhemoglobin to be estimated. Both optical properties and chromophore concentrations can then be used as optical biomarkers for a wide range of applications.

25 March 2021 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
MAMatthew B. Applegate
Matthew B. Applegate
CGCarlos A. Gómez
Carlos A. Gómez
DRDarren M. Roblyer
Darren M. Roblyer
Diffuse optical spectroscopy (DOS) is an optical technique that utilizes multiply scattered light to measure biological tissues. Frequency domain DOS (FD-DOS) is a variant, in which the light source is temporally modulated at radio frequencies (e.g., 50 to 1000 MHz). By measuring the changes in amplitude and phase of the optical signal after it passes through tissue, the absorption (μa) and reduced scattering (μs′) coefficients, collectively termed optical properties (OPs), can be determined. Reduced scattering coefficients provide information on tissue microstructure,1 whereas μa can be used to estimate concentrations of tissue chromophores such as oxy-hemoglobin, deoxy-hemoglobin, lipid, and water. Hemodynamic information can give insight into tissue metabolism which has proven useful in tracking breast cancer response to treatment,2,3 has revealed new information about functional activation in the brain,4 – 6 and can be used to monitor metabolic activity in both muscles7 and joints.8

15 June 2021 in Biomedical Optics Express
Verified
Journal Article
Open access
RIRaeef Istfan
Raeef Istfan
CGCarlos A. Gómez
Carlos A. Gómez
MAMatthew Applegate
Matthew Applegate
DRDmitry Rozenberg
Dmitry Rozenberg
WRW. Darlene Reid
W. Darlene Reid
DRDarren Roblyer
Darren Roblyer
Mechanical ventilation (MV) is used to assist spontaneous breathing in critically ill patients in the intensive care unit (ICU). MV is a cornerstone of critical care medicine but it is now known that inspiratory muscle dysfunction due to injury, disuse, and/or atrophy during MV plays a major role in outcomes for these patients. For example, prolonged MV is strongly correlated with dysfunction of the sternocleidomastoid (SCM), an accessory inspiratory muscle that has been linked to weaning failure from MV. Hemodynamic monitoring of the SCM may provide an important non-invasive and real-time means to monitor MV. In this work, we first conducted multi-layer Monte Carlo simulations to confirm the ability of near infrared light to detect changes in the oxygenation of the SCM over wide ranges of skin tones and adipose layer thicknesses. We then optimized a custom digital frequency domain near-infrared spectroscopy (FD-NIRS) system for continuous 10 Hz measurements of the SCM at 730 nm and 850 nm. A healthy volunteer study was conducted (N=10); subjects performed sets of isometric neck flexions of the SCM. Substantial changes in oxyhemoglobin + oxymyoglobin (oxy[Hb + Mb]), deoxyhemoglobin + deoxymyoglobin (deoxy[Hb + Mb]), and total hemoglobin + myoglobin (total[Hb + Mb]) were observed during sustained and intermittent isometric flexions. There were notable sex differences observed in the magnitude of hemodynamic changes (∼2x larger changes in males for oxy[Hb + Mb] and deoxy[Hb + Mb]). The magnitude of hemodynamic changes when taking into account µs′ changes during flexions was ∼ 2-2.5x larger as compared to assuming constant scattering (CS), which is a common assumption used for continuous wave (CW) NIRS methods. This study suggests that FD-NIRS provides improved accuracy for hemodynamic monitoring of the SCM compared to CW-NIRS, and that FD-NIRS may provide value for SCM monitoring during MV.

9 April 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
MAMatthew B. Applegate
Matthew B. Applegate
RARobert Amelard
Robert Amelard
CGCarlos A. Gomez
Carlos A. Gomez
DRDarren Roblyer
Darren Roblyer
Objective: Frequency-domain diffuse optical spectroscopic imaging (FD-DOS) is a non-invasive method for measuring absolute concentrations of tissue chromophores such as oxy- and deoxy-hemoglobin in vivo . The utility of FD-DOS for clinical applications such as monitoring chemotherapy response in breast cancer has previously been demonstrated, but challenges for further clinical translation, such as slow acquisition speed and lack of user feedback, remain. Here, we propose a new high speed FD-DOS instrument that allows users to freely acquire measurements over the tissue surface, and is capable of rapidly imaging large volumes of tissue. Methods: We utilize 3D monocular probe tracking combined with custom digital FD-DOS hardware and a high-speed data processing pipeline for the instrument. Results are displayed during scanning over the surface of the sample using a probabilistic Monte Carlo light propagation model. Results: We show this instrument can measure absorption and scattering coefficients with an error of 7% and 1% respectively, with 0.7 mm positional accuracy. We demonstrate the equivalence of our visualization methodology with a standard interpolation approach, and demonstrate two proof-of-concept in vivo results showing superficial vasculature in the human forearm and surface contrast in a healthy human breast. Conclusion: Our new FD-DOS system is able to compute chromophore concentrations in real-time (1.5 Hz) in vivo . Significance: This method has the potential to improve the quality of FD-DOS image scans while reducing measurement times for a variety of clinical applications.

1 September 2022 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
DMDiana Mojahed
Diana Mojahed
MAMatthew B. Applegate
Matthew B. Applegate
HGHua Guo
Hua Guo
BTBret Taback
Bret Taback
RHRichard Ha
Richard Ha
CHChristine P. Hendon
Christine P. Hendon
Technologies allowing for real-time histology evaluation may impact the entire anatomic diagnostic process across multiple organs—from biopsy to intraoperative margin assessment to tissue grossing as well as tissue banking.1,2 The macroscopic examination of excised tissue (i.e., tissue grossing) is a critical step in the diagnostic anatomic pathology process as it defines regions of interest requiring further analysis, but it is limited by the variable correlation between gross and microscopic findings.3,4 This fundamental discordance is a gap that could be closed by the application of real-time histology evaluation by optical coherence tomography (OCT). OCT is a nondestructive, 3D microscopic imaging modality with cellular-level resolution5 that is being applied currently in clinical ophthalmology6 and dermatology7 and is emerging in other specialties.8,9 OCT provides a resolution and depth of field that is midway between traditional microscopy and clinical ultrasound. Although ultrasound can achieve a large imaging depth (several centimeters), it has limited resolution (>10  μm). On the other hand, traditional microscopy techniques such as confocal microscopy have very high resolution (<1  μm), but the penetration depth is minimal (<1  mm). OCT bridges the gap between clinical and microscopic imaging, providing 1 to 2 mm of penetration depth and high resolution (1 to 10  μm). Once integrated into the diagnostic workflow, we envision OCT improving the diagnostic process for radiologists by real-time assessment of biopsies; for surgeons by intraoperative margin determination; and for pathologists by identification of regions of interest in pathology grossing/tissue banking, increasing efficiencies of the laboratory by reducing block submission, and reducing pathologist workload by reviewing fewer slides. The aim of OCT in the diagnostic arena is to provide for real-time broad-spectrum assessment of tissue characterization including normal, abnormal, and neoplastic tissues.

1 March 2023 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
MAMatthew B. Applegate
Matthew B. Applegate
KKKivanc Kose
Kivanc Kose
SGSandesh Ghimire
Sandesh Ghimire
MRMilind Rajadhyaksha
Milind Rajadhyaksha
JDJennifer Dy
Jennifer Dy
PurposeDeep learning has demonstrated excellent performance enhancing noisy or degraded biomedical images. However, many of these models require access to a noise-free version of the images to provide supervision during training, which limits their utility. Here, we develop an algorithm (noise2Nyquist) that leverages the fact that Nyquist sampling provides guarantees about the maximum difference between adjacent slices in a volumetric image, which allows denoising to be performed without access to clean images. We aim to show that our method is more broadly applicable and more effective than other self-supervised denoising algorithms on real biomedical images, and provides comparable performance to algorithms that need clean images during training.ApproachWe first provide a theoretical analysis of noise2Nyquist and an upper bound for denoising error based on sampling rate. We go on to demonstrate its effectiveness in denoising in a simulated example as well as real fluorescence confocal microscopy, computed tomography, and optical coherence tomography images.ResultsWe find that our method has better denoising performance than existing self-supervised methods and is applicable to datasets where clean versions are not available. Our method resulted in peak signal to noise ratio (PSNR) within 1 dB and structural similarity (SSIM) index within 0.02 of supervised methods. On medical images, it outperforms existing self-supervised methods by an average of 3 dB in PSNR and 0.1 in SSIM.Conclusionnoise2Nyquist can be used to denoise any volumetric dataset sampled at at least the Nyquist rate making it useful for a wide variety of existing datasets.