Shuxian Gao

Shuxian Gao

Auto-generated profile, based on publicly available information

Shuxian Gao

UFZHelmholtz Centre for Environmental Research Permoserstr. 15

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2024 in Water Research
Verified
Journal Article
Closed access
YLYan-Jun Liu
Yan-Jun Liu
HYHe-Yun Yang
He-Yun Yang
SGShu-Xian Gao
Shu-Xian Gao
Zhenghao LiZhenghao Li
Zhenghao Li
YHYan-Yun Hu
Yan-Yun Hu
GSGuo-Ping Sheng
Guo-Ping Sheng

13 June 2024 in Analytical Chemistry
Verified
Journal Article
Open access
SGShuxian Gao
Shuxian Gao
EJElaine K. Jennings
Elaine K. Jennings
LHLimei Han
Limei Han
BKBoris Peter Koch
Boris Peter Koch
Peter HerzsprungPeter Herzsprung
Peter Herzsprung
Oliver J. LechtenfeldOliver J. Lechtenfeld
Oliver J. Lechtenfeld
Ultrahigh resolution mass spectrometry (UHRMS) routinely detects and identifies thousands of mass peaks in complex mixtures, such as natural organic matter (NOM) and petroleum. The assignment of several chemically plausible molecular formulas (MFs) for a single accurate mass still poses a major problem for the reliable interpretation of NOM composition in a biogeochemical context. Applying sensible chemical rules for MF validation is often insufficient to eliminate multiple assignments (MultiAs)─especially for mass peaks with low abundance or if ample heteroatoms or isotopes are included - and requires manual inspection or expert judgment. Here, we present a new approach based on mass error distributions for the identification of true and false assignments among MultiAs. To this end, we used the mass error in millidalton (mDa), which was superior to the commonly used relative mass error in ppm. We developed an automatic workflow to group MultiAs based on their shared formula units and Kendrick mass defect values and to evaluate the mass error distribution. In this way, the number of valid assignments of chlorinated disinfection byproducts was increased by 8-fold as compared to only applying 37Cl/35Cl isotope ratio filters. Likewise, phosphorus-containing MFs can be differentiated against chlorine-containing MFs with high confidence. Further, false assignments of highly aromatic sulfur-containing MFs ("black sulfur") to sodium adducts in negative ionization mode can be excluded by applying our approach. Overall, MFs for mass peaks that are close to the detection limit or where naturally occurring isotopes are rare (e.g., 15N) or absent (e.g., P and F) can now be validated, substantially increasing the reliability of MF assignments and broadening the applicability of UHRMS analysis to even more complex samples and processes.

19 June 2026 in Science Advances
Verified
Journal Article
Open access
SGShuxian Gao
Shuxian Gao
BKBoris Peter Koch
Boris Peter Koch
SKSteffen Kümmel
Steffen Kümmel
JTJan Tebben
Jan Tebben
Oliver J. LechtenfeldOliver J. Lechtenfeld
Oliver J. Lechtenfeld
Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) enables nontargeted identification of molecular formulas in natural organic matter (NOM), yet molecular-level isotope analysis at natural abundance remains limited. Here, we present a comprehensive workflow for molecular formula–specific isotope analysis (MSIA) in NOM using FT-ICR MS, including calibration against universal reference materials (RMs). The central step of MSIA is an intensity-tuning strategy that, with sufficient spectral averaging, achieves sub–per mil (‰) precision and accuracy and enables robust isotopic comparison (Δδ 13 C) across samples. Between terrestrial and marine NOM, we observed Δδ 13 C values of 17.3, 8.8, and 10.1‰ for marine-enriched formulas C 19 H 22 O 10 , C 20 H 26 O 9 , and C 20 H 24 O 9 , respectively, whereas an invariant formula, C 18 H 22 O 6 , showed a nonsignificant difference (Δδ 13 C = 2.7‰, P = 0.296). Matrix effects for RMs spiked into NOM were within the method uncertainty, rendering existing RMs suitable for MSIA when matched in carbon number, peak intensity, and mass (<50 daltons). Under these conditions, molecular formula–level δ 13 C values were obtained, e.g., −46.8‰ for C 18 H 22 O 6 in terrestrial NOM.

20 January 2025
Verified
Conference Paper
Open access
SGShuxian Gao
Shuxian Gao
EJElaine Jennings
Elaine Jennings
LHLimei Han
Limei Han
BKBoris Peter Koch
Boris Peter Koch
Peter HerzsprungPeter Herzsprung
Peter Herzsprung
Oliver J. LechtenfeldOliver J. Lechtenfeld
Oliver J. Lechtenfeld
Ultrahigh resolution mass spectrometry (UHRMS) routinely detects and identifies thousands of molecular formulas (MFs) in natural organic matter (NOM). However, multiple assignments (MultiAs) occur when the several chemically plausible MFs are assigned to one single mass peak. MultiAs for a mass peak consist of one common core MF but different “formula residuals”, or replacement pairs, and increase as more heteroatoms and isotopes are being considered during the assignment process. This poses a major problem for the reliable interpretation of NOM composition in a biogeochemical context. A number of approaches have been proposed to rule out false assignments based on structural constraints or isotopologue detection and intensity ratios. But this becomes increasingly challenging for low abundance mass peaks or when stable isotope labeling (e.g. with 15N, 2H) is employed. Here, we present a new approach based on mass error distributions for the identification of true and false-assignments among MultiAs. An automatic workflow was developed for the detection and exclusion of false assignments in MultiAs based on their recurring replacement pairs and Kendrick mass defect values. The workflow can validate MFs for mass peaks that are close to detection limit or where naturally occurring isotopes are rare (e.g. 15N) or absent (e.g. P, F), substantially increasing the reliability of MFs assignments and broadening the applicability of UHRMS in characterization of NOM, e.g. for organic nitrogen and organic phosphorus in different environmental compartments, which are key components for global elemental cycles.

10 October 2026 in Analytical Chemistry
Verified
Journal Article
Open access
Peter HerzsprungPeter Herzsprung
Peter Herzsprung
Oliver J. LechtenfeldOliver J. Lechtenfeld
Oliver J. Lechtenfeld
WTWolf von TümPling
Wolf von TümPling
NKNorbert Kamjunke
Norbert Kamjunke
SGShuxian Gao
Shuxian Gao
Molecular formula (MF) assignment in ultrahigh-resolution mass spectrometry (UHRMS) analyses of dissolved organic matter (DOM) containing multiple non-oxygen heteroatoms (e.g., nitrogen and sulfur) is highly environmentally relevant yet remains challenging. Recent studies of DOM composition in aquaculture systems with protein-rich surface sediments have reported numerous CHNO (N1−8), CHOS (S1−3), and even CHNOS MFs containing multiple N and S atoms, suggesting the presence of oligopeptide-like molecules. Due to insufficient mass resolution, multiple formula assignments (MultiAs) caused by interchangeable replacement pairs, within a mass error threshold of 1 ppm, complicate the validation of MF assignments. While N5S2 formulas are known as likely false-positive assignments of 13C1 isotopologue peaks, the multiple N-containing MFs in MultiAs of potential oligopeptide origins involving replacement pairs with N6 ↔ S1 and S2 ↔ N4 could not be validated properly. Here, we introduce a new chemically informed validation approach based on the elemental composition and stoichiometry of typical peptides with atomic ratios 0.2 < O/C < 0.65 and 1.5 < H/C < 2. Amino acid combinations matched about 36% N-rich MF (n = 960) among N6 ↔ S1 related MultiAs (N7 ↔ N1S1, N8 ↔ N2S1··· N8S2 ↔ N2S3) and 30% N-rich MF (n = 1040) among S2 ↔ N4 related MultiAs (N1S2 ↔ N5, N2S2 ↔ N6···N4S3 ↔ N8S1), supporting the true assignments of N-rich MFs based on oligopeptide stoichiometry. Overall, the chemical complexity of heteroatom-rich DOM warrants advances in MF assignment for UHR mass spectra by expanding the analytical window to include multiple-heteroatom formulas, which would especially benefit protein-rich samples from aquaculture systems or wastewater.