Jalila Zirar

Jalila Zirar

Auto-generated profile, based on publicly available information

Jalila Zirar

Mohamed V University

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2022 in Advances in Virology
Verified
Journal Article
Open access
PDF file
STSophia Tazi
Sophia Tazi
HKHakima Kabbaj
Hakima Kabbaj
JZJalila Zirar
Jalila Zirar
AZAmal Zouaki
Amal Zouaki
GAGhizlane El Amin
Ghizlane El Amin
MSMyriam Seffar
Myriam Seffar
Background. RT-PCR is the gold standard for COVID-19 diagnosis, but the lack of standardization of assays, whose diagnostic performance may widely vary, complicates the interpretation of the discrepancies that may be encountered. Study design. We conducted a retrospective study over a ten-month period at the Central Laboratory of Virology of Ibn Sina University Hospital of Rabat. We included nasopharyngeal swabs, positive and negative for SARS-CoV-2 on FilmArray BioFire® Respiratory Panel 2.1 Plus, which were subjected to our laboratorys reference test, MAScIR SARS-CoV-2 M kit 2.0, initially or after a freeze-thaw cycle. The results were compared, and each discrepant sample with sufficient volume underwent the third test, using ARGENE® SARS-CoV-2 R-GENE kit. Results. Of 80 SARS-CoV-2 negative samples on FilmArray, there were no discordant results, whereas of 80 SARS-CoV-2 positive samples on FilmArray, 21 had discordant results on MAScIR, and only 11 could be tested on ARGENE, revealing positive results in 6 cases. 12.7 and 76.5 correspond to the discordance rates for MAScIR (with one or both targets detected on FilmArray), while 14.3 and 100 correspond to those of ARGENE. As the estimated sensitivity and specificity of FilmArray, compared with MAScIR, were 100 and 79.2, respectively, its lower limit of detection, and ARGENE assay results, made it difficult to distinguish between false positives on FilmArray and false negatives on MAScIR without further investigations. Conclusion. The implementation of a new assay in our laboratory revealed discrepancies suggesting a lack of sensitivity of our laboratorys reference test, leading us consequently to retain the SARS-CoV-2 positive result of these discordant samples on FilmArray, regardless of the detection of one or both targets. Our study, which is, to our knowledge, the first comparing FilmArray RP2.1 and MAScIR 2.0 assays for SARS-CoV-2 detection, highlights the urgent need to standardize RT-PCR assays for COVID-19 diagnosis.