Grupo de Pesquisa em Sensores Eletroquímicos e nano(Materiais) – SEnM Laboratório de Corrosão e Nanotecnologia – LCNT Núcleo de Competência em Petróleo e Gás de Sergipe – NUPEG Departamento de Química – DQI Universidade Federal de Sergipe – UFS CEP 49.100-000 São Cristóvão, SE Brasil
Auto-generated profile, based on publicly available information
José Fernando de Macedo
Grupo de Pesquisa em Sensores Eletroquímicos e nano(Materiais) – SEnM Laboratório de Corrosão e Nanotecnologia – LCNT Núcleo de Competência em Petróleo e Gás de Sergipe – NUPEG Departamento de Química – DQI Universidade Federal de Sergipe – UFS CEP 49.100-000 São Cristóvão, SE Brasil
Caffeine (CAF) and nicotine (NIC) are emerging contaminants and are among the most consumed substances in the world, making it crucial to monitor these contaminants. In this work, an alternative electrolyte, 2-hydroxyethylammonium acetate (2HEAA) was used for the development of an electroanalytical method for determination and quantification of CAF and NIC, simultaneously, using differential pulse voltammetry (DPV). The system with the 2HEAA electrolyte was characterized by cyclic voltammetry and electrochemical impedance spectroscopy, and the DPV parameters were optimized for the best conditions. The method was validated from a calibration curve obtained which showed limit of detection (LOD) of 0.82 and 6.26 μmol L-1 and limit of quantification (LOQ) of 2.73 and 20.8 μmol L-1 for CAF and NIC, respectively. In the precision analyses, values lower than 10% of relative standard deviation were obtained. In the presence of concomitant inorganic and organic species, the system proved to be selective in the determination of analytes. The method was used to determine the analytes in fortified samples (river water, synthetic urine and commercial milk), obtaining recoveries between 87.25 and 111.40%. The 2HEAA demonstrated high efficiency as an alternative electrolyte with good signal-to-noise ratio, increased analytical sensitivity of the method, in addition to presenting low cost and fast electrolyte preparation.
Patients with systemic lupus erythematosus have a poor prognosis of pregnancy, since it is associated with significant maternal and fetal morbidity, including spontaneous miscarriage, pre-eclampsia, intrauterine growth restriction, fetal death and pre-term delivery. We report a case with successful pregnancy in a patient with systemic lupus erythematosus and hypertension. A 39-year-old nulliparous woman presented with systemic lupus erythematosus with antinuclear and antiphospholipid antibodies, hypertension and recurrent pregnancy loss presented for assisted reproduction. The patient responded well to enoxaparin and prednisone during both assisted reproduction and prenatal treatment. This case report indicates that prescription of immunosuppressant and blood thinners can be safely recommended throughout the whole prenatal period in patients with systemic lupus erythematosus. Enoxaparin and prednisone may be prescribed concurrently during pregnancy.
25 August 2023 in Brazilian Journal of Analytical Chemistry
This work aims to develop a modified electrode with N-doped carbon dots (CPE/N-CD) for the voltammetric detection of 17α-ethinylestradiol (EE2) in solution. N-doped carbon dot nanoparticles (N-CD) were synthesized using citric acid and urea as the nitrogen source. The N-doped carbon dots were characterized by absorption and emission spectroscopy in the ultraviolet and visible regions, electronic absorption spectroscopy in the infrared region, and Raman Spectroscopy, which showed evidence of the formation of the material. Electrochemical analyses were conducted utilizing Differential Pulse Voltammetry (DPV). After optimization of electrochemical parameters, a calibration plot was produced for the sensor, demonstrating a linear range of 0.01 to 0.80 μmol L-1 (R2 = 0.9969). Additionally, the sensor exhibited a detection limit (LOD) of 0.59 nmol L-1 and a quantification limit (LOQ) of 2.00 nmol L-1. The studies on reproducibility and repeatability revealed RSDs of 1.63% and 3.61% respectively. The results obtained using CPE/N-CD indicate that the developed electrode exhibits excellent analytical performance, making it suitable for identifying and quantifying EE2 in solution.