Jia-Wei Wu

Jia-Wei Wu

Auto-generated profile, based on publicly available information

Jia-Wei Wu

Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2026 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Open access
PDF file
JWJia-Wei Wu
Jia-Wei Wu
XSXin Sun
Xin Sun
ZLZi-Kai Li
Zi-Kai Li
XMXue-Ni Meng
Xue-Ni Meng
QLQian Li
Qian Li
QFQing Fu
Qing Fu
Background: Stack-of-spirals ultrashort echo time (spiral-UTE) has been reported to be feasible for lung imaging; however, the performance of free-breathing contrast-enhanced and unenhanced spiral-UTE (UTEe and UTEu) is still unknown. Therefore, this study aimed to evaluate their performance of lung imaging in patients with malignant tumors. Methods: A total of 76 patients with malignancies suspected of pulmonary metastatic nodules were enrolled in free-breathing UTEe, UTEu and routine contrast-enhanced T1-weighted imaging [volumetric interpolated breath-hold examination (VIBE)] for lung follow-up. Two radiologists independently assessed the image quality, and qualitative analysis was scored via a 5-point scale (4, excellent; 0, unreadable) with respect to the visibility of fissures, airways and vessels; signal homogeneity; motion artifacts; lesion conspicuity; and overall image quality. Quantitative analysis included measurements of the apparent contrast-to-noise ratio (CNR) and apparent signal-to-noise ratio (SNR). Pulmonary nodules detected via magnetic resonance (MR) images were compared with those by computed tomography (CT) as the reference standard. Results: Both UTEu and UTEe outperformed VIBE in all the qualitative metrics (P0.05) in those metrics. UTEe exhibited the best performance in depicting pulmonary vessels, achieving the highest apparent SNR and apparent CNR values. Among the 130 pulmonary nodules identified via CT, spiral-UTE had a sensitivity of 76.9% and a positive predictive value (PPV) of 99.0%, significantly outperforming VIBE (sensitivity of 47.7% and PPV of 95.4%). The detection rates for spiral-UTE were 90.0% for nodules larger than 5 mm, 98.5% for nodules larger than 7 mm and 100.0% for nodules larger than 10 mm. Conclusions: Spiral-UTE demonstrated superior image quality and greater sensitivity for pulmonary nodule detection than breath-hold VIBE did. Both unenhanced and enhanced spiral-UTE showed comparable performance in nodule detection, highlighting its potential as a reliable imaging modality for patients with malignant tumors during follow-up imaging.