Lygia Maria Paulo da Silva Braga

Lygia Maria Paulo da Silva Braga

Auto-generated profile, based on publicly available information

Lygia Maria Paulo da Silva Braga

Laboratory of Microbiology Control, Department of Quality Control, Bio-Manguinhos/Fiocruz, Rio de Janeiro/RJ, Brazil

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2022 in Letters in Applied Microbiology
Verified
Journal Article
Closed access
LBL.M.P.S. Braga
L.M.P.S. Braga
BSB.A.A. Saad
B.A.A. Saad
COC.T.F. de Oliveira
C.T.F. de Oliveira
CVC.E. Volpe-Chaves
C.E. Volpe-Chaves
MLM.L.G.G. Lacerda
M.L.G.G. Lacerda
MBMarcelo Lima Brandão
Marcelo Lima Brandão

28 June 2024 in PDA Journal of Pharmaceutical Science and Technology
Verified
Journal Article
Closed access
PDF file
JMJosiane Machado Vieira Mattoso
Josiane Machado Vieira Mattoso
LCLUCIANA Veloso da COSTA
LUCIANA Veloso da COSTA
BVBruna de Almeida Do Vale
Bruna de Almeida Do Vale
CRCristhiane Falavina dos Reis
Cristhiane Falavina dos Reis
JAJoyce Modesto de Andrade
Joyce Modesto de Andrade
MBMarcelo Lima Brandão
Marcelo Lima Brandão
Microbiological contamination may cause microbial proliferation and consequently additional problems for pharmaceutical companies through production stoppage, product contamination, investigations of process deviations, out-of-specification results and product disposal. This is one of the major concerns of the regulatory health agencies. Microbiological load (bioburden) may represent a potential risk for patients if the sterilization process is not effective and/or due to the production of toxins. Although bioburden can be eliminated by terminal sterilization or filtration processes, it is important to monitor the amount and determine the identity and characteristics of the microorganisms present prior to final processing. The application of microorganism identification systems is crucial for identifying the type of contamination, which can be extremely useful for investigating. The aim of this study was to evaluate the profiles of microorganisms identified in bioburden assays from solutions, culture medias, and products (SCP) from a pharmaceutical industry facility. From 2018-2020, a total of 1,078 samples from 857 different lots of SCP were analyzed and isolated microorganisms were identified. A prefiltering step was included after March 2020, in order to reduce the bioburden before sterilizing filtration. Criteria for the definition and management of microorganisms identified were evaluated after an integrative bibliographic review, and three groups were proposed (critical, objectionable, and nonobjectionable microorganisms). For the samples that did not include prefiltering (n=636), 227 (35.7%) presented microbial growth. For those that included prefiltering, before prefiltering (n=221), 60.6% presented microbial growth, and after prefiltering, this value was reduced to 4.1%, which can be attributed to a contamination during the sampling or a wrong filtering. From the samples that presented microbial growth, 678 microorganisms were identified as bacteria and 59 as molds and yeasts. A total of 120 microorganisms (56 and 27 Gram-positive and negative bacteria, respectively, 31 yeasts, and six filamentous molds) could not be identified, and the remaining microorganisms were classified as objectionable (n=507; 82.2%), nonobjectionable (n=103; 16.7%) and critical (n=7; 1.1%). Most of the bioburden species (>80.0%) were considered objectionable microorganisms. A process for classification and management of bioburden analysis results based on a literature review of pathogenic and physiological characteristics of the microorganisms was proposed.

16 July 2023 in Revista Científica do UBM
Verified
Journal Article
Open access
PDF file
LCLUCIANA Veloso da COSTA
LUCIANA Veloso da COSTA
CRCristhiane Moura Falavina Dos Reis
Cristhiane Moura Falavina Dos Reis
LBLygia Maria Paulo da Silva Braga
Lygia Maria Paulo da Silva Braga
RMRebeca Vitória Da Silva Lage De Miranda
Rebeca Vitória Da Silva Lage De Miranda
MBMarcelo Lima Brandão
Marcelo Lima Brandão
The objective of this study was to evaluate the presence of inhibitory activity in water analysis vials collected at high temperatures. Seven microbial strains were used. A total of 100 mL of water at a temperature of 85°C was added to eight water collection bottles from manufacturers A and B. In another eight flasks, 100 mL of water at room temperature was added. <100 Colony Forming Units (CFU) were inoculated into the respective flasks for each strain. Subsequently, the CFU no. was determined by membrane filtration. All microorganisms showed ≥50% recovery compared to the control and no significant differences were observed (P=0.76). The percent recovery ranged from 57.9-188.5% and 56.3-183.8% from manufacturers A and B, respectively, and no significant differences were observed (P=0.81). It is concluded that no inhibitory activity was seen and that the vials would be suitable for use in collecting water at temperatures up to 85°C. El objetivo de este estudio era evaluar la presencia de actividad inhibidora en viales de análisis de agua recogidos a altas temperaturas. Se utilizaron siete cepas microbianas. Se añadió un total de 100 mL de agua a una temperatura de 85°C a ocho botellas de recogida de agua de los fabricantes A y B. En otros ocho matraces se añadieron 100 mL de agua a temperatura ambiente. Se inocularon <100 unidades formadoras de colonias (UFC) en los respectivos matraces para cada cepa. Posteriormente, se determinó el número de UFC mediante filtración por membrana. Todos los microorganismos mostraron una recuperación ≥50% en comparación con el control y no se observaron diferencias significativas (P=0,76). Los porcentajes de recuperación oscilaron entre el 57,9-188,5% y el 56,3-183,8% de los fabricantes A y B, respectivamente, y no se observaron diferencias significativas (P=0,81). Se concluye que no se verificó ninguna actividad inhibitoria y que las botellas serían adecuadas para su uso en la captación de agua a temperaturas de hasta 85ºC. água coletadas em altas temperaturas. Sete cepas microbianas foram utilizadas. Foram adicionados 100 mL de água na temperatura de 85ºC em oito frascos para coleta de água dos fabricantes A e B. Em outros oito frascos foram adicionados 100 mL de água na temperatura ambiente. Foram inoculados <100 Unidades Formadores de Colônia (UFC), nos respectivos frascos para cada cepa. Posteriormente, foi determinado o n.º UFC por filtração em membrana. Todos os micro-organismos apresentaram recuperação ≥50% em comparação com o controle e não foram observadas diferenças significativas (P=0,76). O percentual de recuperação variou de 57,9-188,5% e de 56,3-183,8% dos fabricantes A e B, respectivamente, e não foram observadas diferenças significativas (P=0,81). Conclui-se que não foi verificada atividade inibitória e que os frascos estariam aptos para utilização na coleta de águas em temperaturas de até 85ºC.