Johannes Castelein

Johannes Castelein

Auto-generated profile, based on publicly available information

Johannes Castelein

Department of Radiology, University Medical Center Groningen, Groningen, The Netherlands

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2024 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
JCJohannes Castelein
Johannes Castelein
ADAmanda S. Duus
Amanda S. Duus
PBPernille S. Bække
Pernille S. Bække
ISIngolf Sack
Ingolf Sack
MAMatthias S. Anders
Matthias S. Anders
RBRonald J. H. Borra
Ronald J. H. Borra
Background: Cardiac magnetic resonance elastography (MRE) shows promise in assessing the mechanofunctional properties of the heart but faces clinical challenges, mainly synchronization with cardiac cycle, breathing, and external harmonic stimulation.Purpose: To determine the reproducibility of in vivo cardiac multifrequency MRE (MMRE) for assessing diastolic left ventricular (LV) stiffness and viscosity.Study Type: Prospective.Subjects: This single‐center study included a total of 28 participants (mean age, 56.6 ± 23.0 years; 16 male) consisting of randomly selected healthy participants (mean age, 44.6 ± 20.1 years; 9 male) and patients with aortic stenosis (mean age, 78.3 ± 3.8 years; 7 male).Field Strength/Sequence: 3 T, 3D multifrequency MRE with a single‐shot spin‐echo planar imaging sequence.Assessment: Each participant underwent two cardiac MMRE examinations on the same day. Full 3D wave fields were acquired in diastole at frequencies of 80, 90, and 100 Hz during a total of three breath‐holds. Shear wave speed (SWS) and penetration rate (PR) were reconstructed as a surrogate for tissue stiffness and inverse viscous loss. Epicardial and endocardial ROIs were manually drawn by two independent readers to segment the LV myocardium.Statistical Tests: Shapiro–Wilk test, Bland–Altman analysis and intraclass correlation coefficient (ICC). P‐value <0.05 were considered statistically significant.Results: Bland–Altman analyses and intraclass correlation coefficients (ICC = 0.96 for myocardial stiffness and ICC = 0.93 for viscosity) indicated near‐perfect test–retest repeatability among examinations on the same day. The mean SWS for scan and re‐scan diastolic LV myocardium were 2.42 ± 0.24 m/s and 2.39 ± 0.23 m/s; the mean PR were 1.24 ± 0.17 m/s and 1.22 ± 0.14 m/s. Inter‐reader variability showed good to excellent agreement for myocardial stiffness (ICC = 0.92) and viscosity (ICC = 0.85).Data Conclusion: Cardiac MMRE is a promising and reproducible method for noninvasive assessment of diastolic LV stiffness and viscosity.Level of Evidence: 2Technical Efficacy: 1

13 April 2024 in American Journal of Transplantation
Verified
Journal Article
Open access
THTim L. Hamelink
Tim L. Hamelink
BOBaran Ogurlu
Baran Ogurlu
CPCarolina C. Pamplona
Carolina C. Pamplona
JCJohannes Castelein
Johannes Castelein
SBSigrid S. Bennedsgaard
Sigrid S. Bennedsgaard
CMCyril Moers
Cyril Moers
Normothermic machine perfusion (NMP) is increasingly considered for pre-transplant kidney quality assessment. However, fundamental questions about differences between in vivo and ex vivo renal function, as well as the impact of ischemic injury on ex vivo physiology, remain unanswered. This study utilized magnetic resonance imaging (MRI), alongside conventional parameters to explore differences between in vivo and ex vivo renal function and the impact of warm ischemia on a kidney's behavior ex vivo. Renal MRI scans and samples were obtained from living pigs (n=30) in vivo. Next, kidney pairs were procured and exposed to minimal, or 75 min of warm ischemia, followed by 6 hours of hypothermic machine perfusion. Both kidneys simultaneously underwent 6-hour ex vivo perfusion in MRI-compatible NMP circuits to obtain multiparametric MRI data. Ischemically injured ex vivo kidneys showed a significantly altered regional blood flow distribution compared to in vivo and to minimally damaged organs. Both ex vivo groups showed diffusion restriction relative to in vivo. Our findings underscore the differences between in vivo and ex vivo MRI-based renal characteristics. Therefore, when assessing organ viability during NMP, it should be considered to incorporate parameters beyond the conventional functional markers that are common in vivo.

9 November 2023 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
JCJohannes Castelein
Johannes Castelein
CPCarolina Pamplona
Carolina Pamplona
RJRoberto Armstrong Junior
Roberto Armstrong Junior
MSMarina Vidal dos Santos
Marina Vidal dos Santos
ISIngolf Sack
Ingolf Sack
RBRonald Borra
Ronald Borra
Stiffness plays a vital role in diagnosing renal fibrosis. However, perfusion influences renal stiffness in various chronic kidney diseases. Therefore, we aimed to characterize the effect of tissue perfusion on renal stiffness and tissue fluidity measured by tomoelastography based on multifrequency magnetic resonance elastography in an ex vivo model. Five porcine kidneys were perfused ex vivo in an MRI-compatible normothermic machine perfusion setup with adjusted blood pressure in the 50/10–160/120 mmHg range. Simultaneously, renal cortical and medullary stiffness and fluidity were obtained by tomoelastography. For the cortex, a statistically significant (p &lt; 0.001) strong positive correlation was observed between both perfusion parameters (blood pressure and resulting flow) and stiffness (r = 0.95, 0.91), as well as fluidity (r = 0.96, 0.92). For the medulla, such significant (p &lt; 0.001) correlations were solely observed between the perfusion parameters and stiffness (r = 0.88, 0.71). Our findings demonstrate a strong perfusion dependency of renal stiffness and fluidity in an ex vivo setup. Moreover, changes in perfusion are rapidly followed by changes in renal mechanical properties—highlighting the sensitivity of tomoelastography to fluid pressure and the potential need for correcting mechanics-derived imaging biomarkers when addressing solid structures in renal tissue.

27 May 2026 in Annals of Coloproctology
Verified
Journal Article
Open access
PDPaulina Daniluk-Marsy
Paulina Daniluk-Marsy
JCJohannes Castelein
Johannes Castelein
KPKarol Polom
Karol Polom
Luigi MaranoLuigi Marano
Luigi Marano
RBRonald J. H. Borra
Ronald J. H. Borra
Intraoperative hypoperfusion is a major risk factor for postoperative anastomotic complications in colorectal surgery. Although most perfusion assessments emphasize arterial inflow, the roles of latency, sustained fluorescence, and venous outflow remain underexplored. This study aimed to identify quantitative indocyanine green (ICG) fluorescence parameters predictive of intraoperative hypoperfusion. Eighty patients who underwent colorectal cancer resection between 2018 and 2022 were analyzed. Intraoperative perfusion was evaluated qualitatively using near-infrared ICG angiography and quantitatively through post hoc analysis of fluorescence time-intensity curves. Associations with hypoperfusion were assessed using group comparisons and receiver operating characteristic (ROC) analysis. Qualitative evaluation indicated hypoperfusion requiring intraoperative relocation of the anastomotic site in 12 patients (15%), with postoperative leakage in 1 patient (1.2%) despite revision of the anastomosis. Quantitative analysis showed that latency was significantly shorter in hypoperfused cases (5.5 seconds [interquartile range (IQR), 1.0-13.0 seconds] vs. 20.0 seconds [IQR, 6.8-27.0 seconds]; P=0.003), and the plateau intensity ratio (PIR; Fplateau/Fmax) was markedly decreased (0.6 [IQR, 0.6-0.7] vs. 0.8 [IQR, 0.6-0.9]; P=0.045). The ROC analysis demonstrated good diagnostic performance for latency (area under the curve [AUC], 0.76; sensitivity, 33.3% [95% confidence interval (CI), 13.8-60.9]; specificity, 92.8% [95% CI, 84.1-96.9]; positive likelihood ratio, 4.6) and moderate accuracy for PIR (AUC, 0.68; sensitivity, 66.7% [95% CI, 39.1-86.2]; specificity, 68.1% [95% CI, 56.4-77.9]; positive likelihood ratio, 2.1). Quantitative fluorescence analysis identified latency and PIR as complementary markers of perfusion dynamics. Whereas latency reflects early arterial inflow kinetics, PIR captures outflow characteristics related to microvascular and venous integrity. Combining these metrics may improve intraoperative detection of hypoperfusion and support data-driven decisions regarding anastomotic site selection.

14 June 2025 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
JCJohannes Castelein
Johannes Castelein
RBRonald J. H. Borra
Ronald J. H. Borra
AHAdam E. Hansen
Adam E. Hansen

25 May 2026 in European Journal of Surgical Oncology
Verified
Journal Article
Open access
PDPaulina Daniluk-Marsy
Paulina Daniluk-Marsy
JCJohannes Castelein
Johannes Castelein
KPKarol Polom
Karol Polom
RBRonald J.H. Borra
Ronald J.H. Borra
Anastomotic leakage (AL) remains a major complication after colorectal cancer surgery (CCS). Intraoperative indocyanine green (ICG) fluorescence angiography is widely used to assess bowel perfusion, but interpretation is largely subjective. Quantitative analysis of fluorescence kinetics combined with machine learning (ML) may enable more objective, physiology-based risk stratification. In this single-centre retrospective feasibility study, 81 patients undergoing colorectal cancer resection with ICG perfusion assessment were analysed. Intraoperative fluorescence videos were post-processed to extract four quantitative perfusion metrics. Eight clinical variables with plausible relevance to microvascular health were included. Intraoperative hypoperfusion (n = 12, 15%) was defined by delayed fluorescence propagation judged by the operating surgeon. Logistic regression with elastic-net regularisation and three non-linear algorithms (random forest, XGBoost, support vector machine) were trained using perfusion metrics-only, clinical variables-only, and combined feature sets. Performance was evaluated with repeated stratified 5-fold cross-validation and bootstrap confidence intervals. Using perfusion-only features, elastic-net logistic regression achieved a ROC-AUC of 0.76 (95% CI 0.62-0.88). Clinical-only models reached a ROC-AUC of 0.77 (95% CI 0.59-0.93) with random forest. The combined model (perfusion + clinical) yielded the highest discrimination (ROC-AUC 0.81, 95% CI 0.63-0.94) with good calibration (Brier score 0.14). SHAP analysis identified increased latency and lower plateau intensity ratio (PIR) as the strongest predictors of hypoperfusion. Quantitative ICG perfusion indices, particularly latency and PIR, combined with interpretable ML models, can predict surgeon-assessed intraoperative hypoperfusion during colorectal cancer surgery with good discrimination. These findings support further development of explainable, perfusion-guided decision-support tools to reduce anastomotic risk.