Nasirul Haque

Nasirul Haque

Auto-generated profile, based on publicly available information

Nasirul Haque

National Institute of Technology, Calicut, PO, India

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2017 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
DMD. Mishra
D. Mishra
NHN. Haque
N. Haque
ABA. Baral
A. Baral
SCS. Chakravorti
S. Chakravorti
Accumulation of interfacial space charge in oil-paper interface is a critical issue in insulation diagnostics of transformers. This interfacial charge mainly accumulates due to the conductivity difference of oil and paper. Accumulation of interfacial charge leads to localized field enhancement, which further leads to partial discharges and acceleration in the aging of insulation. Therefore, from the point of view of transformer insulation diagnostics, assessment of interfacial charge is very important. However, it is not easy to estimate interfacial space charge behavior from the transformer diagnostics methods currently in use. In case of Polarization-Depolarization Current (PDC) measurement, a well known method for transformer condition monitoring, the effect of interfacial charge is reflected in the non-linearity of current response during polarization and de-polarization. During de-polarization process, a part of the interfacial charge accumulated during polarization period is absorbed by the electrodes producing a current, which is difficult to separate using conventional linear dielectric theory. In this paper, an attempt has been made to separate this current component from de-polarization current through considering charge de-trapping mechanism. Terming this current component as de-trapping current, its relationship with other parameters of transformer insulation is discussed. The developed methodology has been applied on several practical transformers. It was observed that the time constant of de-trapping current is related to the paper conductivity, oil conductivity, dissipation factor and age of the insulation.

7 February 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
NHNasirul Haque
Nasirul Haque
AJAadil Jamshed
Aadil Jamshed
KCKingshuk Chatterjee
Kingshuk Chatterjee
SCSoumya Chatterjee
Soumya Chatterjee
In this paper, a novel approach for accurate sensing of incipient faults occurring in power transformers is proposed using dissolved gas analysis (DGA) technique. The Duval pentagon method is a popular technique often used to interpret faults occurring in a power transformer based on DGA data. However, one potential limitation of conventional Duval pentagon method is the presence of rigid fault boundaries within the pentagon which often lead to misinterpretations, leading to poor detection accuracy. Considering this issue, in this paper a modification of Duval pentagon method is proposed, where instead of using rigidly separated distinct fault zones, a density-based clustering (DBSCAN) approach is used to increase the resiliency and the accuracy of fault detection technique. At first, DBSCAN is used to form different fault clusters within the Duval pentagon. Following this, the centroid corresponding to each fault cluster within the Duval pentagon is determined. For accurate sensing of incipient transformer faults Euclidean distances between the respective centroids and the fault points of the input DGA data are proposed as new distinguishing features in this work. The proposed distance parameters combined with the relative gas concentration measures are finally served as input features to the random forest (RF) classifier, which returned very high classification accuracy. The performance of the RF classifier is also compared with three benchmark machine classifiers, all of which delivered acceptable results. The proposed method can be used for sensing of power transformer faults using Duval pentagon method with increased accuracy.

14 October 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
DMDeepak Mishra
Deepak Mishra
ABArijit Baral
Arijit Baral
NHNasirul Haque
Nasirul Haque
SCSivaji Chakravorti
Sivaji Chakravorti
Utilities prefer non-invasive methods for assessing the condition of power transformer insulation. Analysis of Polarization-Depolarization Current (PDC) is one such popular method. One such analysis involves estimation of trapped charge released from the interfacial region of oil-paper insulation. Literature shows that such charges can be reliably used for diagnosis of transformer insulation. However, such analysis requires a complete profile of PDC. PDC measurement (an offline technique) takes a large amount of time (several hours) to complete. The magnitude of PDC data for a larger value of time is also sensitive to changes in environmental conditions and field noise as its magnitude is low. Hence, a reliable estimation of de-trapped charge may require numerous PDC measurements. This situation is not convenient for utilities as it prolongs shut down time. In the present paper, a method has been proposed which is capable of estimating de-trapping charge using PDC data measured for a short span of time. The proposed method is tested on data collected from several real life in-service transformers.

14 January 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
DMDeepak Mishra
Deepak Mishra
SDSaurabh Dutta
Saurabh Dutta
ABArijit Baral
Arijit Baral
NHNasirul Haque
Nasirul Haque
SCSivaji Chakravorti
Sivaji Chakravorti
Activation energy is popularly used for estimation of remaining life of transformer insulation. It is defined as the average rate of all reactions that happen with cellulose. Existing literature shows that activation energy of oil-paper insulation can be obtained from Polarization Depolarization Current (PDC) and Return Voltage Measurement (RVM) data that are measured at a specific temperature. It is practically difficult to ensure the same measurement temperature for both PDC and RVM data. On the other hand, PDC data and its analysis get influenced by de-trapping current. This de-trapping current is generated by ionic charge carriers that get freed from trap sites during PDC measurement process. Formation of these trap sites are related to physical, chemical reactions that happens at oil-paper interface. The present paper proposes a methodology which uses de-trapped charge, dislodged from deep and shallow traps, to assess insulation condition and for prediction of activation energy. Thus, eliminating the need of RVM data. The proposed method is tested using data collected from various real-life in-service transformers.

24 February 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
KSKaushik Sit
Kaushik Sit
ADArup Kumar KUMAR Das
Arup Kumar KUMAR Das
DMDebojyoti Mukherjee
Debojyoti Mukherjee
NHNasirul Haque
Nasirul Haque
SDSuhas Deb
Suhas Deb
BCBiswendu Chatterjee
Biswendu Chatterjee
In this article, an efficient technique has been proposed to estimate the contamination level of overhead polymeric insulators. Deposition of contamination on polymeric insulator surface, is a serious issue as it often results in the flashover and even insulator failure. For estimating the severity of contamination level, surface leakage current (SLC) signals of a 11kV polymeric insulator with contaminated surface has been analyzed in time-frequency domain through hyperbolic window stockwell transform (HST). HST is more flexible than classical stockwell transform. Also, HST can able to handle both the low and high frequencies adequately. Considering the advantage, HST has been used here to estimate contamination degree from SLC signature. HST analysis of SLC signal returned a 2d complex time-frequency HS matrix. The complex time-frequency HS matrix has been separated into magnitude and phase spectrum. Based on the phase and magnitude spectrum, 15 statistical features, namely HST features has been extracted. Thereafter, 5 relevant HST features have been selected through least absolute shrinkage and selection operator (LASSO) feature selection technique. Finally, these relevant HST features are fed to four machine learning classifiers for estimation of contamination degree. It has also been observed that, the proposed framework method offered better classification accuracy compared to other standard time-frequency analysis and existing methods available in literature.

1 February 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
SCSoumyadeep Chowdhury
Soumyadeep Chowdhury
NHNasirul Haque
Nasirul Haque
SCSoumya Chatterjee
Soumya Chatterjee
Arpan Kumar PradhanArpan Kumar Pradhan
Arpan Kumar Pradhan
SCSivaji Chakravorti
Sivaji Chakravorti
This paper proposes a novel method for predicting FDS characteristics of oil-paper insulation at a temperature, which is different from the measurement temperature, through estimating activation energy. The predicted FDS characteristics curves at different temperatures show a very good agreement with each other when compared to the experimentally measured characteristics. From the FDS characteristics, two moisture sensitive parameters are proposed for accurate estimation of moisture content of oil-paper insulation. The proposed technique is experimentally validated on several test samples with different moisture contents and also on a real-life transformer.