Qianchen Sun

Qianchen Sun

Auto-generated profile, based on publicly available information

Qianchen Sun

Department of Engineering, Centre for Smart Infrastructure and Construction, University of Cambridge, Cambridge, UK

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 October 2020 in Structural Health Monitoring
Verified
Journal Article
Open access
PDF file
QSQianchen Sun
Qianchen Sun
MEMohammed Elshafie
Mohammed Elshafie
CBChris Barker
Chris Barker
AFAnthony Fisher
Anthony Fisher
JSJennifer Schooling
Jennifer Schooling
YRYi Rui
Yi Rui
Integrity testing of deep cast in situ concrete foundations is challenging due to the intrinsic nature of how these foundations are formed. Several integrity test methods have been developed and are well established, but each of these have strengths and weaknesses. A relatively recent integrity testing method is thermal integrity testing. The fundamental feature is the early age concrete release of heat during curing; anomalies such as voids, necking, bulging and/or soil intrusion inside the concrete body result in local temperature variations. Temperature sensors installed on the reinforcement cage collect detailed temperature data along the entire pile during concrete curing to allow empirical identification of these temperature variations. This article investigates a new approach to the interpretation of the temperature variations from thermal integrity testing of cast in situ concrete piles and presents a field case study of this approach. The approach uses the heat of hydration and heat transfer theory and employs numerical modelling using the finite element method. The finite element model can be customised for different concrete mixes and pile geometries. The predicted temperature profile from the numerical model is then compared, in a systematic manner, to the field test temperature data. Any temperature discrepancies indicate potential anomalies of the pile structure. The proposed new interpretation approach could potentially reduce construction costs and increase the anomaly detection accuracy compared to traditional interpretation methods.

6 September 2023 in Structural Health Monitoring
Verified
Journal Article
Open access
QSQianchen Sun
Qianchen Sun
MEMohammed Zeb Elshafie
Mohammed Zeb Elshafie
XXXiaomin Xu
Xiaomin Xu
JSJennifer Schooling
Jennifer Schooling
Thermal integrity testing has been successfully used to assess the quality of cast-in-place piles for the past decade. It employs temperature data measured during concrete curing to identify defects along the piles’ length. However, the uptake of this technology has been rather limited in the piling industry. The main concerns are that the method is not standardised and its reliability is not well understood. In order to address these, there are a number of fundamental questions that need to be explored in more detail, including (a) the optimum time to conduct the assessment, (b) the defect thermal impact, (c) the zone of influence on temperature sensors, (d) the minimum detectable size of a defect and (e) the associated optimum sensor location required. In this paper, experimental and numerical studies were conducted to examine these questions. Fibre optic sensors were employed on model concrete piles in laboratory tests to provide fully distributed temperature data throughout the curing process. The test results showed that the optimum time to assess the defects is approximately at 60% of the time to reach peak temperature and the minimal detectable defect size, using the currently available optical fibre sensor technology, is 4% of the cross-sectional area. In addition, the thermal influence of different defect sizes is presented. Following this, it is shown in the paper that the minimum numbers of sensor cables required to identify defects with cross-sectional areas of 4%, 5% and 8% are eight, six and four cables, respectively. The optimum layout of these sensor cables within a pile cross-section has also been discussed. When specifying pile instrumentation for integrity assessment, the findings of this paper enable practising engineers to make informed judgements in relation to the size of defects they would like to detect (and hence the associated risk this entails) together with the corresponding instrumentation layout required.