Artur Szlubowski

Artur Szlubowski

Auto-generated profile, based on publicly available information

Artur Szlubowski

Endoscopy Unit, Pulmonary Hospital, Zakopane, Poland

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2010 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Closed access
ASArtur Szlubowski
Artur Szlubowski
MZMarcin Zieliński
Marcin Zieliński
JSJerzy Soja
Jerzy Soja
JAJouke T. Annema
Jouke T. Annema
WSWitold Sośnicki
Witold Sośnicki
AĆAdam Ćmiel
Adam Ćmiel
This prospective study aimed to assess the diagnostic yield of the combined approach - endobronchial (EBUS) and endoscopic (EUS) ultrasound-guided needle aspiration (combined ultrasound-needle aspiration (CUS-NA)) in the radiologically normal mediastinum in non-small-cell lung cancer (NSCLC) staging. CUS-NA was performed simultaneously under local anaesthesia and sedation in consecutive NSCLC patients with mediastinal nodes that were not enlarged on CT (stage IA-IIB). All patients with negative CUS-NA subsequently underwent the transcervical extended bilateral mediastinal lymphadenectomy (TEMLA) as a confirmatory test. A total of 120 NSCLC patients underwent CUS-NA between 1 January 2008 and 31 December 2008. There were 318 mediastinal nodes biopsied (158 EBUS-NA - stations: 2R - 2, 2L - 1, 4R - 34, 4L - 33 and 7 - 88 and 160 EUS-NA - stations: 4L - 57, 7 - 101 and 9 - 2). CUS-NA revealed metastatic lymph node involvement in 19 of 120 patients (16%) and in 31 of 318 biopsies (10%). The prevalence was 22%. In 99 patients with negative CUS-NA, who underwent subsequent TEMLA, metastatic nodes were diagnosed in nine patients (8%) in 11 stations: 2R - 2, 4R - 4, 4L - 1, 5 - 3 and 7 - 1. In all but one patient there were 'minimal N2' only. Diagnostic sensitivity, specificity, total accuracy, positive predictive value (PPV) and negative predictive value (NPV) of CUS-NA for normal mediastinum was 68% (95% confidence interval (CI): 48-84), 98% (95% CI: 92-100), 91% (95% CI: 86-96), 91% (95% CI: 70-99) and 91% (95% CI: 83-96), respectively. The sensitivity of CUS-NA was significantly higher than with EBUS-NA alone (p=0.04) and higher, close to the level of significance than with EUS-NA alone (p=0.07). The NPV of all techniques was high and that of CUS-NA was significantly higher than EBUS-NA alone and EUS-NA alone (p=0.01, p=0.03). No complications of CUS-NA were observed. In the radiologically normal mediastinum, CUS-NA is a highly effective and safe technique in NSCLC staging and, if negative, a surgical diagnostic exploration of the mediastinum may be omitted.

1 May 2010 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Closed access
ASArtur Szlubowski
Artur Szlubowski
FHFelix J.F. Herth
Felix J.F. Herth
JSJerzy Soja
Jerzy Soja
MKMarcin Kołodziej
Marcin Kołodziej
JFJoanna Figura
Joanna Figura
JPJuliusz Pankowski
Juliusz Pankowski
The aim of the study was to assess the diagnostic yield of the endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) in restaging of the non-small-cell lung cancer (NSCLC) patients after neo-adjuvant therapy. In a consecutive group of NSCLC patients with pathologically confirmed N2 disease, who underwent neo-adjuvant chemotherapy, EBUS-TBNA was performed. All patients with negative EBUS-TBNA underwent subsequently the transcervical extended bilateral mediastinal lymphadenectomy (TEMLA) as a confirmatory test. A total of 61 patients underwent restaging EBUS-TBNA between 1 June 2007 and 31 December 2008. There were 85 mediastinal lymph nodes biopsied (stations: 2R - 2, 4R - 24, 2L - 1, 4L - 18 and 7 - 40). EBUS-TBNA revealed metastatic lymph node involvement in 18 of 61 patients (30%) and in 22 of 85 biopsies (26%). In 43 patients with negative or uncertain EBUS-TBNA, who underwent subsequent TEMLA, metastatic nodes were diagnosed in nine patients (15%) - in seven (12%) in stations accessible for EBUS-TBNA (stations: 2R - 1, 4R - 5, 7 - 4) and in two (3%) in station not accessible for EBUS-TBNA (station: 5 - 2). The false-negative results of biopsies were found only in small nodes (5.8+/-2.8 mm x 7.5+/-2 mm). Moreover, all positive N2 nodes diagnosed by TEMLA contained only small metastatic deposits. There were three of 61 (5%) patients with false-positive results of biopsies in stations: 4R - 1, 4L - 1, and 7 - 2. A diagnostic sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) of the restaging EBUS-TBNA was 67% (95% confidence interval (CI) - 65-90), 86% (95% CI - 82-95), 80%, 91% (95% CI - 80-100) and 78% (95% CI - 73-93), respectively. No complications of EBUS-TBNA were observed. EBUS-TBNA is an effective and safe technique for mediastinal restaging in NSCLC patients, and after the data presented in our study, in patients with negative results of EBUS-TBNA, a surgical restaging of the mediastinum might not be mandatory.

12 January 2014 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Closed access
ASA. Szlubowski
A. Szlubowski
MSM. Zieli Ski
M. Zieli Ski
JSJ. Soja
J. Soja
AFA. Filarecka
A. Filarecka
SOS. Orzechowski
S. Orzechowski
AMA. Miel
A. Miel
The aim of this prospective trial was to assess the diagnostic utility of combined endobronchial (EBUS) and endoscopic (EUS) ultrasound-guided needle aspiration by use of a single ultrasound bronchoscope (CUSb-NA) in non-small-cell lung cancer (NSCLC) restaging in patients after induction therapy. In a consecutive group of NSCLC patients with pathologically confirmed N2 disease (clinical stage IIIa and IIIb) who underwent induction chemotherapy, CUSb-NA was performed. All of the patients with negative or suspected for metastases (uncertain) diagnosed by endoscopy underwent subsequently transcervical extended mediastinal lymphadenectomy (TEMLA) as a confirmatory test. From January 2009 to December 2012, 106 patients met the inclusion criteria and underwent restaging CUSb-NA under mild sedation, in whom 286 (mean 2.7, range 2-5) lymph node stations were biopsied, 127 (mean 1.2, range 1-3) by EBUS-transbronchial needle aspiration (TBNA) and 159 (mean 1.5, range 1-4) by EUS-fine needle aspiration (FNA). The CUSb-NA revealed metastatic lymph node involvement in 37/106 patients (34.9%). In 69 (65.1%) patients with negative and uncertain CUSb-NA in 4 (3.8%) out of them, who underwent subsequent TEMLA metastatic nodes were found in 18 patients (17.0%) and there were single lymph nodes found only in one mediastinal station (minimal N2) in 10 (9.4%) out of them. False-positive results were found in 2 (1.9%) patients. In 9 (8.5%) patients CUSb-NA occurred to be false negative in Stations 2R and 4R (only accessible for EBUS), exclusively in small nodes and in 4 (3.8%) patients in Station 5-not accessible for CUSb-NA. The prevalence of mediastinal lymph node metastases in the present study was 51.9%. Diagnostic sensitivity, specificity, total accuracy, positive predictive value and negative predictive value (NPV) of the restaging CUSb-NA were 67.3% (95% CI [confidence interval]-53-79), 96.0% (95% CI-86-99), 81.0% (95% CI-73-87), 95.0% (95% CI-83-99) and 73.0% (95% CI-61-83), respectively. The sensitivity, accuracy and NPV of CUSb-NA were higher compared with EBUS-TBNA and EUS-FNA alone. No complications of CUSb-NA were observed. The CUSb-NA is a reasonable and safe technique in mediastinal restaging in NSCLC patients after induction therapy. Following our data, in patients with negative result of CUSb-NA, a surgical restaging of the mediastinum should be considered.

30 January 2018 in Pulmonology
Verified
Journal Article
Open access
ABAntonio Bugalho
Antonio Bugalho
MSM. de Santis
M. de Santis
ASA. Szlubowski
A. Szlubowski
ARAles Rozman
Ales Rozman
RER. Eberhardt
R. Eberhardt
The endobronchial ultrasound (EBUS) scope has been increasingly used in the gastrointestinal tract (EUS-B). Scientific data proves its efficacy and safety to provide a complete lung cancer staging, when combined with EBUS-TBNA, and in the diagnosis of para-esophageal lesions. There are multiple barriers to start performing EUS-B but probably the most important ones are related to knowledge and training, so new operators should follow a structured training curriculum. This review aims to reflect the best current knowledge regarding EUS-B and provide a road map to assist those who are incorporating the technique into their clinical practice.

23 May 2012 in Interactive CardioVascular and Thoracic Surgery
Verified
Journal Article
Open access
PDF file
ASArtur Szlubowski
Artur Szlubowski
JSJerzy Soja
Jerzy Soja
PKPiotr Kocoń
Piotr Kocoń
PTPiotr Talar
Piotr Talar
WCWojciech Czajkowski
Wojciech Czajkowski
JKJarosław Kużdżał
Jarosław Kużdżał
The aim of the study was to compare diagnostic utility of combined (i.e. transbronchial and transoesophageal) ultrasound imaging with needle biopsy of the mediastinum in lung cancer (LC) staging, (a) by use of a single ultrasound bronchoscope (CUSb) and (b) by using two scopes (CUS). In consecutive LC patients, clinical stage IA-IIIB the CUS or CUSb was performed under mild sedation and, if negative, underwent lung resection with confirmatory systematic lymph node dissection. From 214 LC patients, 110 underwent CUS and 104 underwent CUSb (618 biopsies); both revealed metastases in 50% of cases. There was ‘minimal N2’ in 11 of 14 false negative patients. Diagnostic sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) of CUS was 91.7%, 98%, 94.6%, 98.2% and 90.7% respectively and of CUSb was 85%, 93.2%, 88.5%, 94.4%, 82%, respectively with no significant difference in yield of CUS vs CUSb (P = 0.255 and P = 0.192). The mean time of CUS (25 ± 4.4 min) was significantly longer as compared to CUSb (14.9 ± 2.3 min) (P < 0.001). No severe complications of either method were observed. The combined ultrasound imaging of the mediastinum by use of CUSb is significantly less time-consuming and equally as effective and safe as the use of CUS for LC staging.

Verified
Journal Article
Open access
PDF file
ASArtur Szlubowski
Artur Szlubowski
JKJarosław Kużdżał
Jarosław Kużdżał
JPJuliusz Pankowski
Juliusz Pankowski
AOAnna Obrochta
Anna Obrochta
JSJerzy Soja
Jerzy Soja
MZMarcin Zieliński
Marcin Zieliński
Introduction: The aim of the study was to assess the diagnostic yield of ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) in mediastinal or hilar adenopathy in: (1) staging of non-small cell lung cancer (NSCLC) (97); (2) other malignant neoplasms including: small cell lung cancer (SCLC), metastatic neoplasms and Hodgkin’s disease (16); (3) NSCLC recurrence (7); (4) sarcoidosis and other non-malignant diseases (29). Material and methods: Real time EBUS-TBNA was performed under local anaesthesia and sedation in 149 consecutive patients—237 biopsies in groups of lymph nodes: subcarinal (7)—107, all paratracheal (2R, 2L, 4R, 4L)—86, hilar (10R, 10L)—41 and interlobar (11R, 11L)—3. A mean axis of punctured node was 15 mm (range: 7–42 mm). All negative results were verified by transcervical extended bilateral mediastinal lymphadenectomy (TEMLA), mediastinoscopy or thoracotomy. Results: Lymph node biopsy was technically successful in 92% and was diagnostic in 55% of lung cancer patients and in 85.7% of sarcoidosis patients. In NSCLC staging sensitivity of EBUS-TBNA was 88.7%, specificity 100%, accuracy 92.8% and NPV 83.3% (89.7%, 100%, 94.9% and 90.9% per biopsy), and in the whole group it was 91.5%, 98.7%, 94.6% and 87.3% respectively. In 7.2% of NSCLC staging patients with false negative results of EBUS-TBNA (mainly subcarinal) there was observed partial involvement of metastatic lymph nodes, mean 34.3% (range 10–50%), confirmed by TEMLA. Conclusions: The diagnostic value of EBUS-TBNA is very high in lung cancer, NSCLC staging and sarcoidosis.