Kirby A. Witte

Kirby A. Witte

Auto-generated profile, based on publicly available information

Kirby A. Witte

Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA 15213, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 June 2017 in Science
Verified
Journal Article
Closed access
PDF file
JZJuanjuan Zhang
Juanjuan Zhang
PFPieter Fiers
Pieter Fiers
KWKirby A. Witte
Kirby A. Witte
RJRachel W. Jackson
Rachel W. Jackson
KPKatherine L. Poggensee
Katherine L. Poggensee
SCSteven H. Collins
Steven H. Collins
Optimum human input: Exoskeletons can be used to augment human abilities—for example, to lift very heavy loads or to provide greater endurance. For each user, though, a device will need to be adjusted for optimum effect, which can be time-consuming. Zhang et al. show that the human can be included in the optimization process, with real-time adaptation of an ankle exoskeleton (see the Perspective by Malcolm et al. ). By using indirect calorimetry to measure metabolic rates, the authors were able to adjust the torque provided by the device while users were walking, running, and carrying a load. Science , this issue p. 1280 ; see also p. 1230

25 March 2020 in Science Robotics
Verified
Journal Article
Open access
PDF file
KWKirby A. Witte
Kirby A. Witte
PFPieter Fiers
Pieter Fiers
ASAlison L. Sheets-Singer
Alison L. Sheets-Singer
SCSteven H. Collins
Steven H. Collins
Exoskeletons that reduce energetic cost could make recreational running more enjoyable and improve running performance. Although there are many ways to assist runners, the best approaches remain unclear. In our study, we used a tethered ankle exoskeleton emulator to optimize both powered and spring-like exoskeleton characteristics while participants ran on a treadmill. We expected powered conditions to provide large improvements in energy economy and for spring-like patterns to provide smaller benefits achievable with simpler devices. We used human-in-the-loop optimization to attempt to identify the best exoskeleton characteristics for each device type and individual user, allowing for a well-controlled comparison. We found that optimized powered assistance improved energy economy by 24.7 ± 6.9% compared with zero torque and 14.6 ± 7.7% compared with running in normal shoes. Optimized powered torque patterns for individuals varied substantially, but all resulted in relatively high mechanical work input (0.36 ± 0.09 joule kilogram−1 per step) and late timing of peak torque (75.7 ± 5.0% stance). Unexpectedly, spring-like assistance was ineffective, improving energy economy by only 2.1 ± 2.4% compared with zero torque and increasing metabolic rate by 11.1 ± 2.8% compared with control shoes. The energy savings we observed imply that running velocity could be increased by as much as 10% with no added effort for the user and could influence the design of future products.