Ziliang Li

Ziliang Li

Auto-generated profile, based on publicly available information

Ziliang Li

Key Laboratory of Light-Duty Gas-Turbine/Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 January 2020 in Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
Verified
Journal Article
Closed access
PDF file
MWMing-Yang Wang
Ming-Yang Wang
ZLZi-Liang Li
Zi-Liang Li
SZShengfeng Zhao
Shengfeng Zhao
Yanfeng ZhangYanfeng Zhang
Yanfeng Zhang
XLXingen Lu
Xingen Lu
The laminar-turbulent transition process on the compressor blade surface is often induced by the laminar separation flow at low Reynolds number ( Re). In the present study, numerical simulations were conducted to investigate the structure of the laminar separation bubble and its effects on the profile loss of a high subsonic compressor airfoil under different Re conditions, and the mechanism for the performance deterioration of compressor airfoil at low Re was clarified. Besides, the airfoil was redesigned to obtain a series of airfoils with different loading distributions, and the aerodynamic performance of these airfoils was compared and analyzed in detail. According to the simulation results, the laminar separation bubble mainly determined the loss generation process of a compressor airfoil. When Re decreased from 12 × 105 to 1.5 × 105, the laminar separation bubble on the suction surface grew thicker and the length was increased by 11.2% of the axial chord. As such, the reversed flow inside the laminar separation bubble became more obvious and the turbulence level downstream of the maximum thickness of laminar separation bubble was increased. Also, the growth in the turbulent boundary layer was enhanced, causing more serious flow blockage and wake mixing. According to the Denton's profile loss model, the larger trailing edge loss caused by the stronger displacement effect of laminar separation bubble was supposed to be the main reason for the performance deterioration of compressor airfoil under low Re conditions. The ultra-front loading distribution for airfoil has the possibility to suppress or even eliminate the negative effect of laminar separation bubble, and the profile loss was decreased by 26.7% at Re = 1.5 × 105; however, the less significant performance improvement was observed at some higher Re. Moreover, the ultra-front loaded airfoil was less sensitive to the inlet turbulence level and the superiority still holds even at some supercritical conditions.

29 May 2019 in Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
Verified
Journal Article
Closed access
PDF file
ZLZiliang Li
Ziliang Li
XLXingen Lu
Xingen Lu
GHGe Han
Ge Han
Yanfeng ZhangYanfeng Zhang
Yanfeng Zhang
SZShengfeng Zhao
Shengfeng Zhao
JZJunqiang Zhu
Junqiang Zhu
Centrifugal compressors often suffer relatively low efficiency and a terrible operating range particularly due to the complex flow structure and intense impeller/diffuser interaction. Numerous studies have focused on improving the centrifugal compressor performance using many innovative ideas, such as the tandem impeller, which has become increasingly attractive due to its ability to achieve the flow control with no additional air supply configurations and control costs in compressor. However, few studies that attempted to the investigation of tandem impeller have been published until now and the results are always contradictory. To explore the potential of the tandem impeller to enhance the compressor performance and the underlying mechanism of the flow phenomena in the tandem impellers, this paper numerically investigated a high-pressure-ratio centrifugal compressor with several tandem impellers at off-design operating speeds. The results encouragingly demonstrate that the tandem impeller can achieve a performance enhancement over a wide range of operating conditions. Approximately 1.8% maximum enhancement in isentropic efficiency and 5.0% maximum enhancement in operating range are achieved with the inducer/exducer circumferential displacement of λ s = 25% and 50%, respectively. The observed stage performance gain of the tandem impellers decreases when the operating speed increases due to the increased inducer shock, increased wake losses, and deteriorated tandem impeller discharge flow uniformity. In addition, the tandem impeller can extend the impeller operating range particularly at low rotation speeds, which is found to be a result from the suppression of the low-momentum fluid radial movement. The results also indicate that the maximum flux capacity of the tandem impeller decreases due to the restriction of the inducer airfoil Kutta–Joukowsky condition.

30 July 2019 in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
Verified
Journal Article
Closed access
PDF file
YZYingjie Zhang
Yingjie Zhang
Yanfeng ZhangYanfeng Zhang
Yanfeng Zhang
XLXingen Lu
Xingen Lu
GHGe Han
Ge Han
ZLZiliang Li
Ziliang Li
High-pressure ratio centrifugal compressors usually adopt vaned diffusers to reach high efficiency. Nevertheless, the compressor operating range might be narrow on account of the diffuser stall resulting from the large flow separations in diffuser passages at low flow rates. Flow control techniques, aimed at expanding the compressor operating range, are required to suppress these flow separations. In this paper, the flow control strategy, in terms of the slotted diffuser was used to widen the operating range for a highly loaded centrifugal compressor. The main focus of the research is to address the effects of the slotted diffuser vane on the aerodynamic performance, including the underlay flow physics of the compressor. In the case of the baseline compressor, a large flow separation exists near the pressure surface between the hub and approximately 40% of the span inside diffuser passages over the entire flow range. In addition, flow separation appears at the junction of hub and suction surface at low flow rates, which promotes compressor stall. Therefore, a hub-side slotted diffuser is utilized to mitigate the flow separations inside diffuser passages. Through application of the slotted diffuser, the stall margin is improved a lot without performance decline as a result of the improvement of the flow field within diffuser passages. The flow separation on the suction surface is suppressed by a vortex induced by the leakage flow. Additionally, the flow angle at the diffuser inlet becomes more circumferential owing to the leakage flow passing through the slot; thus, the incidence angle is increased, which results in mitigation of the flow separation at the junction of hub and pressure surface. As a result, a 13.5% stall margin increment is gained in the presence of the slotted diffuser vane.

12 August 2025 in Proceedings of the Institution of Mechanical Engineers, Part G: Journal of Aerospace Engineering
Verified
Journal Article
Closed access
ZLZiliang Li
Ziliang Li
ZWZixu Wang
Zixu Wang
YWYanhui Wu
Yanhui Wu
Compressor flow loss is largely contributed by the blade endwall flow deterioration, especially for advanced jet engines operating at high altitudes and low Reynolds number ( Re ) conditions. To reduce the significant losses in the compressor blade endwall regions under low Re , this paper numerically investigates the potential control effect of the inherent upstream wakes - manifesting themselves as periodic flow disturbances within the downstream blade passage - on the aerodynamic performance of a highly loaded compressor cascade at a low Re condition induced via low-speed inflow, and particular emphasis is placed on the upstream wake effect on the endwall flow separation and mechanism. Firstly, the impact of Re on compressor cascade performance is clarified; Then, the optimal upstream wake parameters of sweep frequency ( f ) and flow coefficient ( Ø ) are developed at a relative low Re condition, where a 20.1% reduction in compressor cascade total pressure loss is achieved. Subsequently, the underlying flow mechanism of upstream wake effect on the compressor cascade performance improvement are explored in depth from the perspectives of vortex, separation and secondary flow, where the positive radial vorticity and streamwise vorticity of upstream wakes are proved to play critical roles on the suppression of suction surface laminar separation bubble and endwall, respectively. Furthermore, typical flow structure models of the highly loaded compressor cascade at low Re are developed based on the detailed flow mechanism investigation. All the analyses provide theoretical references for the design of advanced jet engines operating at high altitudes and low Re .

28 April 2022 in Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
Verified
Journal Article
Closed access
ZLZiliang Li
Ziliang Li
YXYapeng Xue
Yapeng Xue
LFLuwen Feng
Luwen Feng
YWYanhui Wu
Yanhui Wu
XLXingen Lu
Xingen Lu
Tandem impeller configuration has the potential to improve the performance of highly loaded transonic centrifugal compressors, while the related research is still in the early stages and general design guidelines, such as the selection of inducer meridional length, are limited so far. In this paper, a highly loaded transonic centrifugal compressor with various tandem impeller configurations is numerically investigated. The objective is to evaluate the impact of inducer meridional length [ ] on the tandem impeller flow structure and performance, and further to look into the underlying flow mechanisms and design principles of the tandem impeller. The results indicate that the inducer meridional length [ ] has significant effect on the tandem impeller and compressor stage performance. There exits an optimized tandem impeller [ ] value of Appr. 38% that achieves a compressor stage pressure ratio and efficiency gain (at the P.E. points) of 2.6% and 1.8%, respectively, and deviating from the optimized [ ] value will lead to deteriorated compressor performance. In terms of the impeller performance, the inducer trailing edge determined by the inducer meridional length [ ] should be located downstream of the passage shock to reduce the shock and inducer wake losses. However, the inducer blade should also be placed in the impeller axial part to avoid the exudcer incidence angle deviation. In terms of the diffuser performance which is partly determined by the impeller discharge flow uniformity, the inducer meridional length [ ] directly affects the tandem impeller discharge flow uniformity by rearranging and controlling the secondary flow patterns, and the flow uniformity is prone to be insensitive to the [ ] variation when the [ ] value is large enough (i.e. ≥30%). Additionally, the [ ] value should be large enough (i.e. ≥20%) to generate intense inducer shedding vortexes, which can suppress the development of Coriolis vortex and finally improve the impeller flow uniformity.