Faith C. Robertson

Faith C. Robertson

Auto-generated profile, based on publicly available information

Faith C. Robertson

Department of Neurosurgery, Massachusetts General Hospital, Boston, Massachusetts

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 May 2017 in OncoImmunology
Verified
Journal Article
Open access
MTMasaki Terabe
Masaki Terabe
FRFaith C. Robertson
Faith C. Robertson
KCKatharine Clark
Katharine Clark
EREmma De Ravin
Emma De Ravin
ABAnja Bloom
Anja Bloom
JBJay A Berzofsky
Jay A Berzofsky
Checkpoint inhibition has established immunotherapy as a major modality of cancer treatment. However, the success of cancer immunotherapy is still limited as immune regulation of tumor immunity is very complicated and mechanisms involved may also differ among cancer types. Beside checkpoints, other good candidates for immunotherapy are immunosuppressive cytokines. TGF-β is a very potent immunosuppressive cytokine involved in suppression of tumor immunity and also necessary for the function of some regulatory cells. TGF-β has three isoforms, TGF-β 1, 2 and 3. It has been demonstrated in multiple mouse tumor models that inhibition of all three isoforms of TGF-β facilitates natural tumor immunosurveillance and tumor vaccine efficacy. However, individual isoforms of TGF-β are not well studied yet. Here, by using monoclonal antibodies (mAbs) specific for TGF-β isoforms, we asked whether it is necessary to inhibit TGF-β3 to enhance tumor immunity. We found that blockade of TGF-β1 and 2 and of all isoforms provided similar effects on tumor natural immunosurveillance and therapeutic vaccine-induced tumor immunity. The protection was CD8+ T cell-dependent. Blockade of TGF-β increased vaccine-induced Th1-type response measured by IFNγ production or T-bet expression in both tumor draining lymph nodes and tumors, although it did not increase tumor antigen-specific CD8+ T cell numbers. Therefore, protection correlated with qualitative rather than quantitative changes in T cells. Furthermore, when combined with PD-1 blockade, blockade of TGF-β1 and 2 further increased vaccine efficacy. In conclusion, blocking TGF-β1 and 2 is sufficient to enhance tumor immunity, and it can be further enhanced with PD-1 blockade.

19 May 2020 in Journal of Medical Internet Research
Verified
Journal Article
Open access
JLJoseph R Linzey
Joseph R Linzey
FRFaith Robertson
Faith Robertson
AHAli S Haider
Ali S Haider
CGChristopher S Graffeo
Christopher S Graffeo
JWJustin Z Wang
Justin Z Wang
JRJames T. Rutka
James T. Rutka
Background: Social media use continues to gain momentum in academic neurosurgery. To increase journal impact and broaden engagement, many scholarly publications have turned to social media to disseminate research. The Journal of Neurosurgery Publishing Group (JNSPG) established a dedicated, specialized social media team (SMT) in November 2016 to provide targeted improvement in digital outreach. Objective: The goal of this study was to examine the impact of the JNSPG SMT as measured by increased engagement. Methods: We analyzed various metrics, including impressions, engagements, retweets, likes, profile clicks, and URL clicks, from consecutive social media posts from the JNSPG’s Twitter and Facebook platforms between February 1, 2015 and February 28, 2019. Standard descriptive statistics were utilized. Results: Between February 2015 and October 2016, when a specialized SMT was created, 170 tweets (8.1 tweets/month) were posted compared to 3220 tweets (115.0 tweets/month) between November 2016 and February 2019. All metrics significantly increased, including the impressions per tweet (mean 1646.3, SD 934.9 vs mean 4605.6, SD 65,546.5; P=.01), engagements per tweet (mean 35.2, SD 40.6 vs mean 198.2, SD 1037.2; P<.001), retweets (mean 2.5, SD 2.8 vs mean 10.5, SD 15.3; P<.001), likes (mean 2.5, SD 4.0 vs mean 18.0, SD 37.9; P<.001), profile clicks (mean 1.5, SD 2.0 vs mean 5.2, SD 43.3; P<.001), and URL clicks (mean 13.1, SD 14.9 vs mean 38.3, SD 67.9; P<.001). Tweets that were posted on the weekend compared to weekdays had significantly more retweets (mean 9.2, SD 9.8 vs mean 13.4, SD 25.6; P<.001), likes (mean 15.3, SD 17.9 vs mean 23.7, SD 70.4; P=.001), and URL clicks (mean 33.4, SD 40.5 vs mean 49.5, SD 117.3; P<.001). Between November 2015 and October 2016, 49 Facebook posts (2.3 posts/month) were sent compared to 2282 posts (81.5 posts/month) sent between November 2016 and February 2019. All Facebook metrics significantly increased, including impressions (mean 5475.9, SD 5483.0 vs mean 8506.1, SD 13,113.9; P<.001), engagements (mean 119.3, SD 194.8 vs mean 283.8, SD 733.8; P<.001), and reach (mean 2266.6, SD 2388.3 vs mean 5344.1, SD 8399.2; P<.001). Weekend Facebook posts had significantly more impressions per post (mean 7967.9, SD 9901.0 vs mean 9737.8, SD 19,013.4; P=.03) and a higher total reach (mean 4975.8, SD 6309.8 vs mean 6108.2, SD 12,219.7; P=.03) than weekday posts. Conclusions: Social media has been established as a crucial tool for the propagation of neurosurgical research and education. Implementation of the JNSPG specialized SMT had a demonstrable impact on increasing the online visibility of social media content.

1 October 2023 in Journal of Neurosurgery
Verified
Journal Article
Closed access
PDF file
FRFaith C. Robertson
Faith C. Robertson
CSChristopher J. Stapleton
Christopher J. Stapleton
JCJean-Valery C. E. Coumans
Jean-Valery C. E. Coumans
FNFederico Nicolosi
Federico Nicolosi
MVManuela Vooijs
Manuela Vooijs
BNBrian V. Nahed
Brian V. Nahed
OBJECTIVE: Surgical skills laboratories augment educational training by deepening one’s understanding of anatomy and allowing the safe practice of technical skills. Novel, high-fidelity, cadaver-free simulators provide an opportunity to increase access to skills laboratory training. The neurosurgical field has historically evaluated skill by subjective assessment or outcome measures, as opposed to process measures with objective, quantitative indicators of technical skill and progression. The authors conducted a pilot training module with spaced repetition learning concepts to evaluate its feasibility and impact on proficiency. METHODS: The 6-week module used a simulator of a pterional approach representing skull, dura mater, cranial nerves, and arteries (UpSurgeOn S.r.l.). Neurosurgery residents at an academic tertiary hospital completed a video-recorded baseline examination, performing supraorbital and pterional craniotomies, dural opening, suturing, and anatomical identification under a microscope. Participation in the full 6-week module was voluntary, which precluded randomizing by class year. The intervention group participated in four additional faculty-guided trainings. In the 6th week, all residents (intervention and control) repeated the initial examination with video recording. Videos were evaluated by three neurosurgical attendings who were not affiliated with the institution and who were blinded to participant grouping and year. Scores were assigned via Global Rating Scales (GRSs) and Task-based Specific Checklists (TSCs) previously built for craniotomy (cGRS, cTSC) and microsurgical exploration (mGRS, mTSC). RESULTS: Fifteen residents participated (8 intervention, 7 control). The intervention group included a greater number of junior residents (postgraduate years 1–3; 7/8) compared to the control group (1/7). External evaluators had internal consistency within 0.5% (kappa probability > Z of 0.00001). The total average time improved by 5:42 minutes (p < 0.003; intervention, 6:05, p = 0.07; control, 5:15, p = 0.001). The intervention group began with lower scores in all categories and surpassed the comparison group in cGRS (10.93 to 13.6/16) and cTSC (4.0 to 7.4/10). Percent improvements for the intervention group were cGRS 25% (p = 0.02), cTSC 84% (p = 0.002), mGRS 18% (p = 0.003), and mTSC 52% (p = 0.037). For controls, improvements were cGRS 4% (p = 0.19), cTSC 0.0% (p > 0.99), mGRS 6% (p = 0.07), and mTSC 31% (p = 0.029). CONCLUSIONS: Participants who underwent a 6-week simulation course showed significant objective improvement in technical indicators, particularly individuals who were early in their training. Small, nonrandomized grouping limits generalizability regarding degree of impact; however, introducing objective performance metrics during spaced repetition simulation would undoubtedly improve training. A larger multiinstitutional randomized controlled study will help elucidate the value of this educational method.

1 May 2021 in World Neurosurgery
Verified
Journal Article
Closed access
UKUlrick Sidney Kanmounye
Ulrick Sidney Kanmounye
FRFaith C. Robertson
Faith C. Robertson
LSLorraine Arabang Sebopelo
Lorraine Arabang Sebopelo
WSWah Praise Senyuy
Wah Praise Senyuy
DSDawin Sichimba
Dawin Sichimba
CGChristopher S Graffeo
Christopher S Graffeo

13 December 2023 in World Neurosurgery
Verified
Journal Article
Closed access
GMGrazia Menna
Grazia Menna
AKAngelos Kolias
Angelos Kolias
IEIgnatius N. Esene
Ignatius N. Esene
EBErnest J. Barthélemy
Ernest J. Barthélemy
SHSamer Hoz
Samer Hoz
FNFederico Nicolosi
Federico Nicolosi

1 May 2022 in Journal of Neurosurgery
Verified
Journal Article
Open access
PDF file
FRFaith C. Robertson
Faith C. Robertson
RSRaahil M. Sha
Raahil M. Sha
Jose Maria AmichJose Maria Amich
Jose Maria Amich
WEWalid Ibn Essayed
Walid Ibn Essayed
ALAvinash Lal
Avinash Lal
WGWilliam B. Gormley
William B. Gormley
OBJECTIVE: A major obstacle to improving bedside neurosurgical procedure safety and accuracy with image guidance technologies is the lack of a rapidly deployable, real-time registration and tracking system for a moving patient. This deficiency explains the persistence of freehand placement of external ventricular drains, which has an inherent risk of inaccurate positioning, multiple passes, tract hemorrhage, and injury to adjacent brain parenchyma. Here, the authors introduce and validate a novel image registration and real-time tracking system for frameless stereotactic neuronavigation and catheter placement in the nonimmobilized patient. METHODS: Computer vision technology was used to develop an algorithm that performed near-continuous, automatic, and marker-less image registration. The program fuses a subject’s preprocedure CT scans to live 3D camera images (Snap-Surface), and patient movement is incorporated by artificial intelligence–driven recalibration (Real-Track). The surface registration error (SRE) and target registration error (TRE) were calculated for 5 cadaveric heads that underwent serial movements (fast and slow velocity roll, pitch, and yaw motions) and several test conditions, such as surgical draping with limited anatomical exposure and differential subject lighting. Six catheters were placed in each cadaveric head (30 total placements) with a simulated sterile technique. Postprocedure CT scans allowed comparison of planned and actual catheter positions for user error calculation. RESULTS: Registration was successful for all 5 cadaveric specimens, with an overall mean (± standard deviation) SRE of 0.429 ± 0.108 mm for the catheter placements. Accuracy of TRE was maintained under 1.2 mm throughout specimen movements of low and high velocities of roll, pitch, and yaw, with the slowest recalibration time of 0.23 seconds. There were no statistically significant differences in SRE when the specimens were draped or fully undraped (p = 0.336). Performing registration in a bright versus a dimly lit environment had no statistically significant effect on SRE (p = 0.742 and 0.859, respectively). For the catheter placements, mean TRE was 0.862 ± 0.322 mm and mean user error (difference between target and actual catheter tip) was 1.674 ± 1.195 mm. CONCLUSIONS: This computer vision–based registration system provided real-time tracking of cadaveric heads with a recalibration time of less than one-quarter of a second with submillimetric accuracy and enabled catheter placements with millimetric accuracy. Using this approach to guide bedside ventriculostomy could reduce complications, improve safety, and be extrapolated to other frameless stereotactic applications in awake, nonimmobilized patients.