Christine Boué

Christine Boué

Auto-generated profile, based on publicly available information

Christine Boué

LPEM, Sorbonne Université, ESPCI Paris- PSL Université, CNRS, 10 Rue Vauquelin, F-75005 Paris, France

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2013 in Journal of Nondestructive Evaluation
Verified
Journal Article
Closed access
PDF file
YFY. Fedala
Y. Fedala
MSM. Streza
M. Streza
FSF. Sepulveda
F. Sepulveda
JRJ.-P. Roger
J.-P. Roger
GTG. Tessier
G. Tessier
CBC. Boué
C. Boué

12 April 2017 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
CBC Boué
C Boué
SHS Holé
S Holé
A crack located in the thermal diffusion zone of a heat source behaves like a thermal barrier modifying the heat diffusion. For a moving continuous source, the sample surface is heated on a little area near the crack for a duration which depends on the speed of the thermal source. A lock-in process synchronized by the displacement of the continuous heat source along the crack is studied. The thermal signature of the crack is extracted via a space operator applied to the amplitude and the phase of surface temperature images for various speeds of the thermal source. With the technical solution presented in this article, the thermal signature images are analysed according to a length representative of the thermal diffusion length to give a local evaluation of the crack depth (around 3 mm at the maximum) for crack lengths of about few centimetres long. The multi-speed lock-in thermography approach is initially studied with finite element method simulations. Experimental tests using an infra-red camera validate the method in a second part. The results do not depend on the heating source if its power is sufficient to produce a temperature rise detectable by an infra-red camera. The depth estimations are obtained independently of the crack width and heat source trajectory. The multi-speed lock-in thermography is a method without contact, without sample preparation, non-polluting, non-destructive and with simple optical adjustments.

4 June 2015 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Open access
CFC. Filloy-Corbrion
C. Filloy-Corbrion
CBC. Boue
C. Boue
EGEmmanuel Géron
Emmanuel Géron
TDThierry Ditchi
Thierry Ditchi
JLJ. Lucas
J. Lucas
GTGilbert Teyssedre
Gilbert Teyssedre
The implementation of space charge measurements based on thermal perturbation on thin films requires an improvement of the temperature distribution estimation at the surface and in the depth of dielectric materials for getting reliable space charge profile measurements. Absolute temperature variations are needed, both in time and space. The present contribution addresses surface temperature measurements based on either thermoelectric or bolometric effects. Both responses have been measured on copper-coated silicon nitride layers and gold-coated polypropylene films heated with a Nd:YAG laser pulse. It is shown that high temporal resolution thermal response can be obtained through the bolometric response and that the information appears nearly independent on the nature of the coating electrode. The setup developed provides good signal to noise ratio for heated electrodes of a few ohm resistance. Strategies are still to develop to get the temperature profile in the insulating sample layer.

21 July 2019 in Quantitative InfraRed Thermography Journal
Verified
Journal Article
Closed access
CBChristine Boué
Christine Boué
SHStéphane Holé
Stéphane Holé
Two original methods using lock-in thermography with a laser excitation are proposed for the estimation without contact of open crack depths in metal. The first uses a modulated punctual thermal source and is well suited for the study of complicated structures. In the second, a continuous moving thermal source allows to scan homogeneous structures. Each method relies on the heat diffusion modifications induced by a crack located in the thermal diffusion area of the synchronised heat source. The thermal signature of the crack is extracted to the amplitude of surface temperature images for various modulation frequencies or various scanning speeds of the thermal source. The thermal signatures are analysed according to a length representative of the thermal diffusion length to give a local evaluation of the crack depth. The obtained results demonstrate the potentiality of active lock-in thermography as a contactless measurement tool for the evaluation of crack depths up to 3 mm.

17 May 2022 in Journal of Nondestructive Evaluation
Verified
Journal Article
Closed access
PDF file
CBC. Boué
C. Boué
SHS. Holé
S. Holé

23 August 2024 in Infrared Physics & Technology
Verified
Journal Article
Closed access
CBC. Boué
C. Boué
SHS. Holé
S. Holé