27 February 2018 in IEEE Sensors Journal
Electromyography (EMG) signals are gaining popularity to develop the prosthetics. In this paper, an efficient multi-channel EMG signal acquisition system has been proposed for upper limb prosthetic application. Various arm exercises have been performed to obtain EMG signals from five different arm muscles for the validation of developed hardware. The muscle's position has been selected by palpation method. Furthermore, the classification algorithms have been examined for seven different activities. Total 29 subjects have been chosen (25 intact and four Amputees) to acquire the EMG data by these activities. To classify the recorded EMG data set, nine time domain and seven frequency domain features have been extracted. A comparative analysis of different classifiers is presented for different muscle position of electrodes. The signal processing and classification algorithms have been processed in MATLAB 2016a. The accuracy of classification ranges for different classification algorithms from 57.69% to 99.92% for all subjects.
9 May 2022 in IEEE Transactions on Cybernetics
The ability to reconstruct the kinematic parameters of hand movement using noninvasive electroencephalography (EEG) is essential for strength and endurance augmentation using exoskeleton/exosuit. For system development, the conventional classification-based brain-computer interface (BCI) controls external devices by providing discrete control signals to the actuator. A continuous kinematic reconstruction from EEG signal is better suited for practical BCI applications. The state-of-the-art multivariable linear regression (mLR) method provides a continuous estimate of hand kinematics, achieving a maximum correlation of up to 0.67 between the measured and the estimated hand trajectory. In this work, three novel source aware deep learning models are proposed for motion trajectory prediction (MTP). In particular, multilayer perceptron (MLP), convolutional neural network-long short-term memory (CNN-LSTM), and wavelet packet decomposition (WPD) for CNN-LSTM are presented. In addition, novelty in the work includes the utilization of brain source localization (BSL) [using standardized low-resolution brain electromagnetic tomography (sLORETA)] for the reliable decoding of motor intention. The information is utilized for channel selection and accurate EEG time segment selection. The performance of the proposed models is compared with the traditionally utilized mLR technique on the reach, grasp, and lift (GAL) dataset. The effectiveness of the proposed framework is established using the Pearson correlation coefficient (PCC) and trajectory analysis. A significant improvement in the correlation coefficient is observed when compared with the state-of-the-art mLR model. Our work bridges the gap between the control and the actuator block, enabling real-time BCI implementation.
16 October 2019 in IEEE Transactions on Industrial Electronics
18 September 2020 in IEEE Transactions on Cybernetics
The EMG signal is a widely focused, clinically viable, and reliable source for controlling bionics and prosthesis devices with the aid of machine-learning algorithms. The decisive step in the EMG pattern recognition (EMG-PR)-based control scheme is to extract the features with minimum neural information loss. This article proposes a novel feature extraction method based on advanced energy kernel-based features (AEKFs). The proposed method is evaluated on a scientific dataset which contains six types of upper limb motion with three different force variations. Furthermore, the EMG signal is acquired for eight upper limb gestures for the testing algorithm on the DSP processor. The efficiency of the proposed feature set has been investigated using classification accuracy (CA), Davies-Bouldin (DB) index-based separability measurement, and time complexity as performance metrics. Moreover, the proposed AEKF features, along with the LDA classifier, have been implemented on the DSP processor (ARM cortex M4) for real-time viability. Offline metrics comparison with the existing approaches prove that AEKF features exhibit lower time complexity along with a higher CA of 97.33%. The algorithm is tested on the DSP processor and CA is reported ≈ 92%. MATLAB 2015a has been deployed in Intel Core i7, 3.40-GHz RAM for all offline analyses.
27 March 2019 in IEEE Sensors Letters
EMG-PR (Electromyography pattern recognition) is extensively recognized in human-machine interactive applications such as prosthesis control and rehabilitation devices. Conventional TD (Time-domain) features have been shown to produce decent performance in upper limb movements' classification. However, performance limitation exists in terms of classification accuracy. Hence, a novel feature set extraction on TDM (Time derivative moments) is proposed to improve the performance of EMG-PR in upper limb motion classification. A standardized and benchmark data base NinaPro (sub-database2) has been used for examination of proposed feature set. Total 8 intact subjects (sub1-sub8) have been selected for 8 grasping motion's EMG signal collection. For classification of features three classification techniques (LDA, QDA, and SVM) have been applied. The average improvisation with respect to conventional TD features was achieved for LDA, QDA, and SVM are 8.08 %, 7.95% and 6.41% respectively.
25 October 2022 in IEEE Transactions on Medical Robotics and Bionics
In EMG based pattern recognition (EMG-PR), deep learning-based techniques have become more prominent for their self-regulating capability to extract discriminant features from large data-sets. Moreover, the performance of traditional machine learning-based methods show limitation to categorize over a certain number of classes and degrades over a period of time. In this paper, an accurate, robust, and fast convolutional neural network-based framework for EMG pattern identification is presented. To assess the performance of the proposed system, five publicly available and benchmark data-sets of upper limb activities were used. This data-set contains 49 to 52 upper limb motions (NinaPro DB1, NinaPro DB2, and NinaPro DB3), Data with force variation, and data with arm position variation for intact and amputated subjects. The classification accuracies of 92.18% (53 classes), 91.56% (49 classes), 84.98% (49 classes of amputees), 95.67% (6 classes with force variation), and 99.12% (8 classes with arm position variation) have been observed during the testing. The performance of the proposed system is compared with the state of art techniques in the literature. The findings demonstrate that classification accuracy and time complexity have been improved significantly. For signal pre-processing and deep learning techniques, Keras which is a high-level API for TensorFlow is utilised to build profound learning models. The proposed method has been tested on the Intel Core i7 3.5GHz, 7th Gen CPU with 8GB DDR4 RAM.