Yueling Lyu

Yueling Lyu

Auto-generated profile, based on publicly available information

Yueling Lyu

Sino-German College of Intelligent Manufacturing, Shenzhen Technology University, Shenzhen, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 July 2020 in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
Verified
Journal Article
Closed access
PDF file
YCYangzhi Chen
Yangzhi Chen
XXXiaoping Xiao
Xiaoping Xiao
DZDaoping Zhang
Daoping Zhang
HXHaifei Xiao
Haifei Xiao
YLYueling Lyu
Yueling Lyu
Based on the space curve meshing theory, a novel noncircular line gear mechanism was advanced, namely, this paper presented a design method of the variable speed ratio noncircular line gear with coplanar axes. Firstly, the universal contact curve equations of the constant speed ratio and variable speed ratio line teeth were established. After the constraint equations of the rotating angle of the driving and driven variable speed ratio noncircular line gears were analyzed and established, the relationship between the rotating angle of the driven variable speed ratio noncircular line gear and the parameter t in the VSR area was assumed to be a piecewise fourth-order curve. Then, the contact curve equations of the variable speed ratio noncircular line gears were derived, and the entity models of variable speed ratio noncircular line gears were built. The prototypes of the parallel axis and intersecting axis variable speed ratio noncircular line gears were manufactured by Stereo Lithography Apparatus, and the speed ratios were measured on the kinematic test rig. The kinematic and finite element analysis results demonstrate that the relationship between the rotating angle of the driven variable speed ratio noncircular line gear and the parameter t conforms to the designed function and the noncircular line teeth smoothly achieve the preset VSR transmission. The proposed design method is helpful to design the variable speed ratio noncircular line gears with lower theoretical sliding rate and wider variation range of the speed ratio; consequently, the designed variable speed ratio noncircular line gears have better applicability in specific variable speed ratio applications.

16 May 2025 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
ZZZhefen Zheng
Zhefen Zheng
JZJIE ZHOU
JIE ZHOU
CXChenglin Xie
Chenglin Xie
YLYueling Lyu
Yueling Lyu
XWXiaoyun Wang
Xiaoyun Wang
ZHZeng-Guang Hou
Zeng-Guang Hou
Although numerous variable stiffness controllers have been proposed, generating compliant and adaptive trajectory that could synchronize with human multiple joints movement remains an open challenge for wearable lower limb rehabilitation robots. In this study, we proposed a new adaptive compliance controller (ACC) for a bilateral hip and knee wearable robotic system via online estimation of users' joints stiffness along with adaptive trajectory deformation algorithm (TDA). A sEMG-driven biarticular Hill-type neuromuscular model was first developed and calibrated to estimate the hip and knee joints’ stiffness. The adaptive TDA was designed to transfer joint stiffness adjustments from human joints for robots to reshape the trajectories for multiple joints smoothly. Robot-assisted overground walking experiments were conducted to comprehensively compare our proposed method with similar approaches, including force-based adaptive compliance, fixed-parameter compliance, and passive control, among five healthy human subjects. The results demonstrated that the proposed ACC outperformed other controllers in matching the desired movements of multiple human joints, showing superior performance in tracking error, muscle activity, and gait symmetry and coordination. These findings emphasized that ACC plays a key role in enabling human-robot synchronization across multiple joints, offering significant potential to improve the efficiency of robot-assisted gait rehabilitation.

14 May 2025 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
YLYueling Lyu
Yueling Lyu
YLYiyue Lin
Yiyue Lin
SZShaofeng Zhao
Shaofeng Zhao
JWJianrui Wei
Jianrui Wei
XZXianyi Zhang
Xianyi Zhang
Lower limb exoskeletons have been designed to assist human walking. However, current unpowered exoskeletons primarily targeted the ankle joint, but neglected the energy storage and recoil within the foot. In this study, we proposed an unpowered foot-ankle exoskeleton with a bionic multi-segment foot structure to mimic energy conservation strategies of natural barefoot walking. An archlike structure was built in the exoskeleton with springs aligning with the medial longitudinal arch and the plantar fascia to store elastic energy in the early and midstance phases and recoil energy in the late stance phase of walking. We found that compared with mass-matched experimental shoes, the exoskeleton reduced the total net metabolic cost of walking by 8.5 ± 3.1% for healthy individuals, and caused a 10.6% reduction in the average activity and a 25.9% reduction in the tissue oxygen saturation index of the soleus. As expected, the exoskeleton did not interfere with the natural motion of the midfoot and ankle joints during walking. The exoskeleton may help reduce energetic penalties by assisting the soleus concentric contraction for propulsion and permitting sufficient intra-foot motion. Our results highlight the importance of utilizing elastic energy storage of intra-foot structures for walking assistance, and imply that implementing a multi-foot structure have a potential to further improve the performance of walking assistance devices.

10 February 2025 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
TYTing Yu
Ting Yu
SZShaofeng Zhao
Shaofeng Zhao
YLYueling Lyu
Yueling Lyu
XZXianyi Zhang
Xianyi Zhang
Walking at the preferred speed, considered as a self-optimized gait pattern, is associated with improved energy conservation and cognitive abilities. However, the neuro-muscular mechanisms underlying the benefits of the preferred walking speed remain unclear. Therefore, this study aimed to determine the differences in ankle neuromuscular control between the preferred and fixed speeds during walking. Eighteen healthy young adults were recruited to perform overground barefoot walking at the preferred speed, the prefer-matched control speed (PMCS), slower fixed speeds (1, 2, 3 and 4 km/h) and faster fixed speeds (5 and 6 km/h). Muscle synergies and intermuscular coherence were calculated using surface electromyography (EMG) signals of ankle muscles. Results showed that the preferred walking speed exhibited one less muscle synergy and higher intermuscular coherence in 8-42 Hz than the PMCS. Additionally, slow walking speeds performed more muscle synergies and weaker couplings between plantar flexors in 26-60 Hz than the preferred speed and faster fixed speeds. Our results demonstrate an impact of the preferred walking speed on ankle neuromuscular control during walking, which might influence energy consumption and brain resource occupation. Besides, the preferred walking speed and faster fixed speeds showed comparable modular control characteristics of ankle muscles, which might provide suggestions for experimental settings when examining individuals’ natural neuromuscular control features.