Mark Estes

Mark Estes

Auto-generated profile, based on publicly available information

Mark Estes

Texas Commission on Environmental Quality Austin TX USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 November 2020 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
PDF file
WLWei Li
Wei Li
YWYuxuan Wang
Yuxuan Wang
CBClaudia Bernier
Claudia Bernier
MEMark Estes
Mark Estes
In coastal environments, sea breeze recirculation has been found to be an important mesoscale meteorological phenomenon that causes high ozone episodes, yet the identification of this small‐scale circulation pattern remains difficult. In this study, a new method was developed to automatically identify sea breeze recirculation in Houston, TX, by applying K‐Means clustering algorithm to surface winds measurements at near‐coast sites during the DISCOVER‐AQ (Deriving Information on Surface Conditions from Column and Vertically Resolved Observations Relevant to Air Quality) field campaign period from August to October 2013. The key to the clustering algorithm is seven features derived from site‐based surface winds on each day, including zonal (U) and meridional (V) winds in the morning and afternoon, 24‐hr transport direction (θ) and the recirculation factor, which is the ratio of net transport distance (L) to wind run distance (S). For comparison, the same clustering was applied to San Antonio, TX, a noncoastal city yet within the synoptic‐scale distance from Houston. Four clusters were obtained for each region, including three synoptic patterns common to both regions and one mesoscale pattern that differs by region, classified as Stagnation and Sea Breeze Cluster for San Antonio and Houston, respectively. The clustering outputs were verified by wind profiler data in Houston. By linking the wind clusters with surface and aircraft ozone measurements, we revealed a clear connection between circulation patterns and daily ozone variability showing that maximum daily average 8‐hr (MDA8) ozone levels and spatial distributions differed by cluster type (e.g., the highest ozone found in the Stagnation/Sea Breeze Cluster and the lowest ozone in the Southerly Cluster). This automatable method of sea breeze identification we developed can be potentially applied to other coastal cities because it has low data requirement and no ad hoc location‐specific adjustments.

14 August 2018 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
PDF file
SWSing‐Chun Wang
Sing‐Chun Wang
YWYuxuan Wang
Yuxuan Wang
MEMark Estes
Mark Estes
RLRuixue Lei
Ruixue Lei
RTRobert Talbot
Robert Talbot
PHPei Hou
Pei Hou
Fire emissions from Mexico and Central America are transported regularly to the U.S. Gulf Coast every spring under prevailing circulation patterns and affect U.S. air quality. Here we use a GEOS‐Chem passive tracer simulation to develop the climatology of transport pathways of fire emissions over a long‐term time period of April and May 2002–2015 and estimate their adverse air quality effects for urban areas along the Gulf Coast. A conceptual model is presented to describe the transport mechanisms, which involve southerly low‐level jets in the lower troposphere and warm conveyor belt in the middle troposphere. The warm conveyor belts and the southerly low‐level jets explain 31% and 69% of the interannual variability of the mid‐altitude (1.5–6 km) and low‐altitude events (0–1.5 km), respectively. Considering both transport and fire emissions, approximately 9% of the study period (59–88 days of 854 days) were identified as large pollution events during which Central American fire emissions adversely impacted surface air quality at several major urban centers along the Gulf Coast, including Houston and Corpus Christi in TX, New Orleans in LA, Mobile in AL, and Pensacola in FL. Compared to clean maritime flow from the Gulf of Mexico, these events were estimated to result in average enhancements of maximum daily average 8‐hr (MDA8) ozone and daily PM2.5 (fine particulate matter <2.5 μm in diameter) in the Gulf Coast cities of 3–12 ppbv and 2–5 μg/m3, respectively. Only one ozone exceedance day (79 ppbv, on 18 May 2003) was found among the fire‐impact days for the Houston region.

24 April 2018 in Atmosphere
Verified
Journal Article
Open access
PDF file
RLRuixue Lei
Ruixue Lei
RTRobert Talbot
Robert Talbot
YWYuxuan Wang
Yuxuan Wang
SWSing-Chun Wang
Sing-Chun Wang
MEMark Estes
Mark Estes
We investigated the impacts of cold fronts on area-wide peak O3 and regional background O3 mixing ratios on a daily scale over the Houston-Galveston-Brazoria (HGB) area of southeastern Texas during the O3 seasons (April–October) of 2003–2016. Back trajectories showed that an 18h time lag existed between arrival of cold fronts in the HGB area and onset of a predominately northerly flow. Cold fronts showed increasing effects on both peak and background O3 over the HGB area. Compared to no front days, average peak O3 mixing ratios during the cold front 1st days, cold front 2+ days, and post frontal days increased 0.7, 5.9, and 9.0 ppbv, respectively while average background O3 increased 2.9, 6.8, and 8.6 ppbv, respectively. The change in wind direction from southerly to northerly was the most important factor causing increasing O3 levels. Wind direction shifts caused variation of other meteorological factors (i.e., wind speed, precipitation, temperature, cloud cover, and relative humidity) and tended to overshadow their effects on O3 over the HGB area. On a long-term and large-scale view, cold fronts over the HGB area could be regarded as interruptions in the cleansing effects of predominantly marine southerly flow from the Gulf of Mexico.


1 September 2019 in Atmospheric Environment
Verified
Journal Article
Closed access
RLRuixue Lei
Ruixue Lei
RTRobert Talbot
Robert Talbot
YWYuxuan Wang
Yuxuan Wang
SWSing-Chun Wang
Sing-Chun Wang
MEMark Estes
Mark Estes