Eugene E. Mukhin

Eugene E. Mukhin

Auto-generated profile, based on publicly available information

Eugene E. Mukhin

Ioffe Institute, Russian Academy of Sciences, St. Petersburg, Russia

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 1999 in Technical Physics
Verified
Journal Article
Closed access
PDF file
VGV. K. Gusev
V. K. Gusev
VGV. E. Golant
V. E. Golant
EGE. Z. Gusakov
E. Z. Gusakov
VDV. V. D’YAchenko
V. V. D’YAchenko
MIM. A. Irzak
M. A. Irzak
VYV. A. Yagnov
V. A. Yagnov
The main parameters and design of the Globus-M spherical tokamak are described, including the modifications introduced after construction was completed. The experimental program and possibilities for...

23 December 2011 in Nuclear Fusion
Verified
Journal Article
Closed access
EME.E. Mukhin
E.E. Mukhin
VSV.V. Semenov
V.V. Semenov
ARA.G. Razdobarin
A.G. Razdobarin
STS. Yu. Tolstyakov
S. Yu. Tolstyakov
MKM.M. Kochergin
M.M. Kochergin
PAP. Andrew
P. Andrew
We present here our recent results on the development and testing of the first mirrors for the divertor Thomson scattering diagnostics in ITER. The Thomson scattering system is based on several large-scale (tens of centimetres) mirrors that will be located in an area with extremely high (3–10%) concentration of contaminants (mainly hydrocarbons) and our main concern is to prevent deposition-induced loss of mirror reflectivity in the spectral range 1000–1064 nm. The suggested design of the mirrors—a high-reflective metal layer on a Si substrate with an oxide coating—combines highly stable optical characteristics under deposition-dominated conditions with excellent mechanical properties. For the mirror layer materials we consider Ag and Al allowing the possibility of sharing the Thomson scattering mirror collecting system with a laser-induced fluorescence system operating in the visible range. Neutron tests of the mirrors of this design are presented along with numerical simulation of radiation damage and transmutation of mirror materials. To provide active protection of the large-scale mirrors we use a number of deposition-mitigating techniques simultaneously. Two main techniques among them, plasma treatment and blowing-out, are considered in detail. The plasma conditions appropriate for mirror cleaning are determined from experiments using plasma-induced erosion/deposition in a CH4/H2 gas mixture. We also report data on the numerical simulation of plasma parameters of a capacitively-coupled discharge calculated using a commercial CFD-ACE code. A comparison of these data with the results for mirror testing under deuterium ion bombardment illustrates the possibility of using the capacitively-coupled discharge for in situ non-destructive deposition mitigation/cleaning.

29 July 2015 in Nuclear Fusion
Verified
Journal Article
Closed access
VGV.K. Gusev
V.K. Gusev
NBN.N. Bakharev
N.N. Bakharev
VBV.A. Belyakov
V.A. Belyakov
BBB.YA. Ber
B.YA. Ber
EBE.N. Bondarchuk
E.N. Bondarchuk
EZE.G. Zhilin
E.G. Zhilin

7 September 2016 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
FLF. Leipold
F. Leipold
RRR. Reichle
R. Reichle
CVC. Vorpahl
C. Vorpahl
EME. E. Mukhin
E. E. Mukhin
ADA. M. Dmitriev
A. M. Dmitriev
EME. Meyer
E. Meyer
First mirrors of optical diagnostics in ITER are subject to charge exchange fluxes of Be, W, and potentially other elements. This may degrade the optical performance significantly via erosion or deposition. In order to restore reflectivity, cleaning by applying radio frequency (RF) power to the mirror itself and thus creating a discharge in front of the mirror will be used. The plasma generated in front of the mirror surface sputters off deposition, restoring its reflectivity. Although the functionality of such a mirror cleaning technique is proven in laboratory experiments, the technical implementation in ITER revealed obstacles which needs to be overcome: Since the discharge as an RF load in general is not very well matched to the power generator and transmission line, power reflections will occur leading to a thermal load of the cable. Its implementation for ITER requires additional R&D. This includes the design of mirrors as RF electrodes, as well as feeders and matching networks inside the vacuum vessel. Mitigation solutions will be evaluated and discussed. Furthermore, technical obstacles (i.e., cooling water pipes for the mirrors) need to be solved. Since cooling water lines are usually on ground potential at the feed through of the vacuum vessel, a solution to decouple the ground potential from the mirror would be a major simplification. Such a solution will be presented.

1 October 2009 in Nuclear Fusion
Verified
Journal Article
Closed access
VGV.K. Gusev
V.K. Gusev
SAS.E. Aleksandrov
S.E. Aleksandrov
VAV. Kh Alimov
V. Kh Alimov
IAI.I. Arkhipov
I.I. Arkhipov
BAB.B. Ayushin
B.B. Ayushin
EZE.G. Zhilin
E.G. Zhilin
Experiments and simulations to achieve high values of plasma parameters at the Globus-M spherical tokamak (ST) at moderate absolute auxiliary heating power (up to 0.8 MW) and high specific heating power (up to 2–3 MW m−3) are described. Important distinguishing features are the low edge safety factor range, which is unusual for STs, 2.7 <q< 5 and small plasma–outer wall space (3–5 cm). High ion heating efficiency with neutral beam injection (NBI) was demonstrated. Results of numerical simulation of fast ion trajectories are described and fast ion generation during the NBI and ion cyclotron resonance heating is discussed. Investigations on their confinement and slowing down are also presented. Reasons for achievement of high IC heating efficiency are outlined. Reliable H-mode regime achievement is described. Transport ASTRA modelling demonstrated that during NB heated H-mode ion heat diffusivity remains neoclassical and the particle diffusion coefficient inside transport barrier decreases significantly. Analysis was performed of divertor tile and special probe surfaces after irradiation by plasma during a large number of shots (3000–10 000 shots). Mixed layer composition is measured and deuterium retention in different tokamak first wall areas is estimated. Plasma jet injection experiments with upgraded plasma jet are described. Jet penetration to the plasma centre with immediate increase of density and temperature drop is proved and analogy with pellet injection is outlined.

1 January 2016 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
MBM. Bassan
M. Bassan
PAP. Andrew
P. Andrew
GKG. Kurskiev
G. Kurskiev
EME. Mukhin
E. Mukhin
THT. Hatae
T. Hatae
MWM. Walsh
M. Walsh