Xu Lin

Xu Lin

Auto-generated profile, based on publicly available information

Xu Lin

College of Aeronautical Engineering, Civil Aviation University of China, Tianjin 300300, People’s Republic of China

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 December 2025 in Measurement Science and Technology
Verified
Journal Article
Closed access
BLBaichun Li
Baichun Li
XLXu Lin
Xu Lin
ZLZhi Li
Zhi Li
JQJunze Qian
Junze Qian
ZHZhenpeng He
Zhenpeng He

18 November 2025 in Measurement Science and Technology
Verified
Journal Article
Closed access
BLBaichun Li
Baichun Li
XLXu Lin
Xu Lin
ZLZhi Li
Zhi Li
JQJunze Qian
Junze Qian
ZHZhenpeng He
Zhenpeng He
The combination of high precision and low cost makes point laser sensors a promising solution for enabling on-machine measurement in intelligent manufacturing systems. When applied to robotic on-machine measurement, the primary challenge lies in the accurate calibration of the sensor’s spatial pose. A further essential step towards achieving high measurement accuracy is the establishment of a reliable mapping model that converts one-dimensional distance readings into three-dimensional coordinates. To overcome these challenges, this paper proposes a dimensionality reduction-based measurement method, which simplifies the inherently complex 3D measurement and calibration task into a computationally tractable process rooted in 1D sensing and numerical solution. First, the coordinate systems associated with the robotic measurement system are established. Based on spatial kinematic chain analysis, an on-machine dimensionality reduction measurement strategy and a corresponding mathematical model are presented. Next, a calibration procedure combining spherical constraints and the Levenberg–Marquardt optimization algorithm is designed to calibrate the sensor coordinate system, which is essential for implementing the proposed method. A multivariate nonlinear equation system is derived to determine the calibration parameters using experimental data. Calibration and verification experiments show that the average measurement deviation for a standard sphere is less than 0.3000 mm. Comparative analysis with existing approaches confirms the feasibility of the proposed method. By integrating a point laser displacement sensor with an industrial robot, this approach offers a cost-effective and accurate solution for three-dimensional on-machine measurement applications.