9 July 2019 in Nuclear Fusion
1 July 2021 in Fusion Engineering and Design
1 September 2019 in Fusion Engineering and Design
1 February 2020 in Review of Scientific Instruments
The requirements of ITER neutral beam injectors (1 MeV, 40 A negative deuterium ion current for 1 h) have never been simultaneously attained; therefore, a dedicated Neutral Beam Test Facility (NBTF) was set up at Consorzio RFX (Padova, Italy). The NBTF includes two experiments: SPIDER (Source for the Production of Ions of Deuterium Extracted from Rf plasma), the full-scale prototype of the source of ITER injectors, with a 100 keV accelerator, to investigate and optimize the properties of the ion source; and MITICA, the full-scale prototype of the entire injector, devoted to the issues related to the accelerator, including voltage holding at low gas pressure. The present paper gives an account of the status of the procurements, of the timeline, and of the voltage holding tests and experiments for MITICA. As for SPIDER, the first year of operation is described, regarding the solution of some issues connected with the radiofrequency power, the source operation, and the characterization of the first negative ion beam.
1 August 2021 in Fusion Engineering and Design
1 August 2022 in Review of Scientific Instruments
Giant negative ion sources for neutral beam injectors deliver huge negative ion currents, thanks to their multi-beamlet configuration. As the single-beamlet optics defines the transmission losses along the beamline, the extraction of a similar current for all beamlets is extremely desirable, in order to facilitate the beam source operation (i.e., around perveance match). This Review investigates the correlation between the vertical profile of beam intensity and the vertical profiles of plasma properties at the extraction region of the source, focusing on the influence of increasing cesium injection. Only by the combined use of all available source diagnostics, described in this Review, can beam features on the scale of the non-uniformities be investigated with a sufficient space resolution. At RF power of 50 kW/driver, with intermediate bias currents and a filter field of 2.4 mT, it is found that the central part of the four vertical beam segments exhibits comparable plasma density and beamlet currents; at the edges of the central segments, both the beam and electron density appear to decrease (probably maintaining fixed electron-to-ion ratio); at the bottom of the source, an increase of cesium injection can compensate for the vertical drifts that cause a much higher presence of electrons and a lower amount of negative ions.