Shorya Awtar

Shorya Awtar

Auto-generated profile, based on publicly available information

Shorya Awtar

University of Michigan Precision Systems Design Lab, Mechanical Engineering

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2013 in Journal of Mechanisms and Robotics
Verified
Journal Article
Closed access
PDF file
SAShorya Awtar
Shorya Awtar
GPGaurav Parmar
Gaurav Parmar
Achieving large motion range (>1 mm) along with nanometric motion quality (<10 nm) simultaneously has been a key challenge in nanopositioning systems. Practical limitations associated with the individual physical components (bearing, actuators, and sensors) and their integration, particularly in the case of multi-axis systems, have restricted the range of currently available nanopositioning systems to approximately 100 μm per axis. This paper presents a novel physical system layout, comprising a bearing, actuators, and sensors, that enables large range XY nanopositioning. The bearing is based on a parallel-kinematic XY flexure mechanism that provides a high degree of geometric decoupling between the two motion axes by avoiding geometric over-constraint, provides actuator isolation that allows the use of large-stroke single-axis actuators, and enables a complementary end-point sensing scheme using commonly available sensors. These attributes help achieve 10 mm × 10 mm motion range in the proposed nanopositioning system. Having overcome the physical system design challenges, a dynamic model of the proposed nanopositioning system is created and verified via system identification. In particular, dynamic nonlinearities associated with the large displacements of the flexure mechanism and resulting controls challenges are identified. The physical system is fabricated, assembled, and tested to validate its simultaneous large range and nanometric motion capabilities. Preliminary closed-loop test results, which highlight the potential as well as pending challenges associated with this new design configuration, are presented.

1 August 2010 in Journal of Mechanical Design
Verified
Journal Article
Closed access
PDF file
SAShorya Awtar
Shorya Awtar
SSShiladitya Sen
Shiladitya Sen

24 January 2013 in Journal of Mechanical Design
Verified
Journal Article
Closed access
PDF file
SSShiladitya Sen
Shiladitya Sen
SAShorya Awtar
Shorya Awtar

30 September 2010 in Journal of Mechanisms and Robotics
Verified
Journal Article
Closed access
PDF file
SAShorya Awtar
Shorya Awtar
KSKevin Shimotsu
Kevin Shimotsu
SSShiladitya Sen
Shiladitya Sen
Redundant constraints are generally avoided in mechanism design because they can lead to binding or loss in expected mobility. However, in certain distributed-compliance flexure mechanism geometries, this problem is mitigated by the phenomenon of elastic averaging. Elastic averaging is a design paradigm that, in contrast with exact constraint design principles, makes deliberate and effective use of redundant constraints to improve performance and robustness. The principle of elastic averaging and its advantages are illustrated in this paper by means of a three-beam parallelogram flexure mechanism, which represents an overconstrained geometry. In a lumped-compliance configuration, this mechanism is prone to binding in the presence of nominal manufacturing and assembly errors. However, with an increasing degree of distributed-compliance, the mechanism is shown to become more tolerant to such geometric imperfections. The nonlinear elastokinematic effect in the constituent beams is shown to play an important role in analytically predicting the consequences of overconstraint and provides a mathematical basis for elastic averaging. A generalized beam constraint model is used for these predictions so that varying degrees of distributed compliance are captured using a single geometric parameter. The closed-form analytical results are validated against finite element analysis, as well as experimental measurements.

1 September 2010 in Journal of Medical Devices
Verified
Journal Article
Closed access
PDF file
SAShorya Awtar
Shorya Awtar
TTTristan T. Trutna
Tristan T. Trutna
JNJens M. Nielsen
Jens M. Nielsen
RARosa Abani
Rosa Abani
JGJames Geiger
James Geiger
This paper presents a new minimally invasive surgical (MIS) tool design paradigm that enables enhanced dexterity, intuitive control, and natural force feedback in a low-cost compact package. The paradigm is based on creating a tool frame that is attached to the surgeon’s forearm, making the tool shaft an extension of the latter. Two additional wristlike rotational degrees of freedom (DoF) provided at an end-effector that is located at the end of the tool shaft are manually actuated via a novel parallel-kinematic virtual center mechanism at the tool input. The virtual center mechanism, made possible by the forearm-attached tool frame, creates a virtual two-DoF input joint that is coincident with the surgeon’s wrist, allowing the surgeon to rotate his/her hand with respect to his/her forearm freely and naturally. A cable transmission associated with the virtual center mechanism captures the surgeon’s wrist rotations and transmits them to the two corresponding end-effector rotations. This physical configuration allows an intuitive and ergonomic one-to-one mapping of the surgeon’s forearm and hand motions at the tool input to the end-effector motions at the tool output inside the patient’s body. Moreover, a purely mechanical construction ensures low-cost, simple design, and natural force feedback. A functional decomposition of the proposed physical configuration is carried out to identify and design key modules in the system—virtual center mechanism, tool handle and grasping actuation, end-effector and output joint, transmission system, tool frame and shaft, and forearm brace. Development and integration of these modules leads to a proof-of-concept prototype of the new MIS tool, referred to as FlexDex™, which is then tested by a focused end-user group to evaluate its performance and obtain feedback for the next stage of technology development.

1 August 2010 in Journal of Mechanical Design
Verified
Journal Article
Closed access
PDF file
SAShorya Awtar
Shorya Awtar
SSShiladitya Sen
Shiladitya Sen