Chelcy R. Ford

Chelcy R. Ford

Auto-generated profile, based on publicly available information

Chelcy R. Ford

Warnell School of Forest Resources, University of Georgia, Athens, GA 30602, USA

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2004 in Tree Physiology
Verified
Journal Article
Open access
PDF file
CFChelcy R. Ford
Chelcy R. Ford
MMMary Anne Mcguire
Mary Anne Mcguire
RMRobert J. Mitchell
Robert J. Mitchell
RTRobert O. Teskey
Robert O. Teskey
We monitored sap flux density (v) diurnally in nine mature southeastern pine (Pinus spp.) trees with a thermal dissipation probe that spanned the sapwood radius. We found the expected pattern of high v near the cambium and decreasing v with depth toward the center of the tree; however, the pattern was not constant within a day or between trees. Radial profiles of trees were steeper earlier in the day and became less steep later in the day. As a result, time-dependent changes in the shape of the radial profile of v were sometimes correlated with daily changes in evaporative demand. As the radial profile became less steep, the inner xylem contributed relatively more to total tree sap flow than it did earlier in the day. We present a 3-parameter Gaussian function that can be used to describe the radial distribution of v in trees. Parameters in the function represent depth in the xylem from the cambium, maximum v, depth in the xylem where maximum v occurs, and the rate of radial change in v with radial depth (β). Values of β varied significantly between trees and with time, and were sometimes correlated with air vapor pressure deficit (D). We hypothesize that this occurred during periods of high transpiration when the water potential gradient became great enough to move water in the inner sapwood despite its probable high hydraulic resistance. We examined discrepancies among estimates of daily water use based on single-point, two-point and multi-point (i.e., every 20 mm in the sapwood) measurements. When radial distribution of v was not considered, a single-point measurement resulted in errors as large as 154% in the estimate of daily water use relative to the estimate obtained from a multi-point measurement. Measuring v at two close sample points (10 and 30 mm) did not improve the estimate; however, estimates derived from v measured at two distant sample points (10 and 70 mm) significantly improved the estimate of daily water use, although errors were as great as 32% in individual trees. The variability in v with depth in the xylem, over time, and between trees indicates that measurements of the radial distribution of v are necessary to accurately estimate water flow in trees with large sapwood areas.

1 September 2004 in Tree Physiology
Verified
Journal Article
Open access
PDF file
CFChelcy R. Ford
Chelcy R. Ford
CGCarol E. Goranson
Carol E. Goranson
RMRobert J. Mitchell
Robert J. Mitchell
Rodney WillRodney Will
Rodney Will
RTRobert O. Teskey
Robert O. Teskey
We monitored the radial distribution of sap flux density (v; g H2O m−2 s−1) in the sapwood of six plantation-grown Pinus taeda L. trees during wet and dry soil periods. Mean basal diameter of the 32-year-old trees was 33.3 cm. For all trees, the radial distribution of sap flow in the base of the stem (i.e., radial profile) was Gaussian in shape. Sap flow occurred maximally in the outer 4 cm of sapwood, comprising 50–60% of total stem flow (F), and decreased toward the center, with the innermost 4 cm of sapwood (11–15 cm) comprising less than 10% of F. The percent of flow occurring in the outer 4 cm of sapwood was stable with time (average CV < 10%); however, the percentage of flow occurring in the remaining sapwood was more variable over time (average CV ≫ 40%). Diurnally, the radial profile changed predictably with time and with total stem flow. Seasonally, the radial profile became less steep as the soil water content (θ) declined from 0.38 to 0.21. Throughout the season, daytime sap flow also decreased as θ decreased; however, nighttime sap flow (an estimate of stored water use) remained relatively constant. As a result, the percentage of stored water use increased as θ declined. Time series analysis of 15-min values of F, θ, photosynthetically active radiation (PAR) and vapor pressure deficit (D) showed that F lagged behind D by 0–15 min and behind PAR by 15–30 min. Diurnally, the relationship between F and D was much stronger than the relationship between F and PAR, whereas no relationship was found between F and θ. An autoregressive moving average (ARIMA) model estimated that 97% of the variability in F could be predicted by D alone. Although total sap flow in all trees responded similarly to D, we show that the radial distribution of sap flow comprising total flow could change temporally, both on daily and seasonal scales.