1 June 2008 in Physiological Measurement
Although many methods have been utilized to measure degrees of body hydration, and in particular to estimate normal hydration states (dry weight, DW) in hemodialysis (HD) patients, no accurate methods are currently available for clinical use. Biochemcial measurements are not sufficiently precise and vena cava diameter estimation is impractical. Several bioimpedance methods have been suggested to provide information to estimate clinical hydration and nutritional status, such as phase angle measurement and ratio of body fluid compartment volumes to body weight. In this study, we present a calf bioimpedance spectroscopy (cBIS) technique to monitor calf resistance and resistivity continuously during HD. Attainment of DW is defined by two criteria: (1) the primary criterion is flattening of the change in the resistance curve during dialysis so that at DW little further change is observed and (2) normalized resistivity is in the range of observation of healthy subjects. Twenty maintenance HD patients (12 M/8 F) were studied on 220 occasions. After three baseline (BL) measurements, with patients at their DW prescribed on clinical grounds (DW(Clin)), the target post-dialysis weight was gradually decreased in the course of several treatments until the two dry weight criteria outlined above were met (DW(cBIS)). Post-dialysis weight was reduced from 78.3 +/- 28 to 77.1 +/- 27 kg (p < 0.01), normalized resistivity increased from 17.9 +/- 3 to 19.1 +/- 2.3 x 10(-2) Omega m(3) kg(-1) (p < 0.01). The average coefficient of variation (CV) in three repeat measurements of DW(cBIS) was 0.3 +/- 0.2%. The results indicate that cBIS utilizing a dynamic technique continuously during dialysis is an accurate and precise approach to specific end points for the estimation of body hydration status. Since no current techniques have been developed to detect DW as precisely, it is suggested as a standard to be evaluated clinically.
1 February 2006 in Journal of Applied Physiology
Discrepancies in body fluid estimates between segmental bioimpedance spectroscopy (SBIS) and gold-standard methods may be due to the use of a uniform value of tissue resistivity to compute extracellular fluid volume (ECV) and intracellular fluid volume (ICV). Discrepancies may also arise from the exclusion of fluid volumes of hands, feet, neck, and head from measurements due to electrode positions. The aim of this study was to define the specific resistivity of various body segments and to use those values for computation of ECV and ICV along with a correction for unmeasured fluid volumes. Twenty-nine maintenance hemodialysis patients (16 men) underwent body composition analysis including whole body MRI, whole body potassium (40K) content, deuterium, and sodium bromide dilution, and segmental and wrist-to-ankle bioimpedance spectroscopy, all performed on the same day before a hemodialysis. Segment-specific resistivity was determined from segmental fat-free mass (FFM; by MRI), hydration status of FFM (by deuterium and sodium bromide), tissue resistance (by SBIS), and segment length. Segmental FFM was higher and extracellular hydration of FFM was lower in men compared with women. Segment-specific resistivity values for arm, trunk, and leg all differed from the uniform resistivity used in traditional SBIS algorithms. Estimates for whole body ECV, ICV, and total body water from SBIS using segmental instead of uniform resistivity values and after adjustment for unmeasured fluid volumes of the body did not differ significantly from gold-standard measures. The uniform tissue resistivity values used in traditional SBIS algorithms result in underestimation of ECV, ICV, and total body water. Use of segmental resistivity values combined with adjustment for body volumes that are neglected by traditional SBIS technique significantly improves estimations of body fluid volume in hemodialysis patients.
1 February 2004 in The International Journal of Artificial Organs
Background: Current concepts of dry weight (DW) prescription are largely based on clinical symptoms because of the difficulty in assessing extracellular fluid volume (ECV) during dialysis. Intradialytic changes in ECV can be recorded as changes in extracellular resistance [Re] by continuous regional calf multifrequency bioimpedance spectroscopy (BIS). We hypothesized that relative changes in calf Re (Re at time ‘0’ over Re at time ‘t’ [Re-0/Re-t]) will become very small when ECV is reduced towards normal and individual dry weight is reached. Method: Intradialytic continuous calf BIS was recorded repeatedly in 15 hemodialysis (HD) patients. The first measurement was performed at the prevailing clinical dry weight (CDW). Next measurements were made after post-HD body weight was gradually decreased by 0.2–0.3 kg per treatment. This procedure was iterated over several subsequent treatments until a treatment was observed where changes in Re-0/Re-t were < 1%. The weight at the end of this treatment was defined as “achieved dry weight (ADW)”. Each Re-0/Re-t curve was fitted using a Matlab program (curve fitting toolbox) to obtain the exact weight at 20 min after beginning of the flattening of the Re-0/Re-t slope (‘dry’ weight estimated from BIS, DW-BIS). Results: Both mean ADW (80.5 ± 34.1 kg) and mean DW-BIS (80.6 ± 34.1) were significantly lower than CDW (81.4 ± 32.0 kg, p < 0.001), but there was no difference between ADW and DW-BIS. However, the average weight reduction from CDW to ADW (0.80 ± 0.15 kg) was significantly higher than from CDW to DW-BIS (0.66 ± 0.14 kg, p < 0.001, paired t-test). When ADW was achieved, pre-dialysis systolic blood pressure (SBP) was lower than at CDW (139.3 ± 32.5 mmHg, vs. 129.4 ± 33 mmHg, p < 0.05), post-HD SBP did not differ. The incidence of clinical symptoms of underhydration was similar at CDW (15 %) and DW-BIS (15 %), but higher at ADW (46 %). Conclusion: Intradialytic continuous calf BIS allows the assessment of changes in extracellular calf resistance as an indicator of changes in extracellular fluid volume. Recording of a continuous Re-0/Re-t slope during dialysis appears to be a promising new tool for the prediction of dry weight in hemodialysis patients.
7 June 2011 in Physiological Measurement
Prescription of an appropriate dialysis target weight (dry weight) requires accurate evaluation of the degree of hydration. The aim of this study was to investigate whether a state of normal hydration (DW(cBIS)) as defined by calf bioimpedance spectroscopy (cBIS) and conventional whole body bioimpedance spectroscopy (wBIS) could be characterized in hemodialysis (HD) patients and normal subjects (NS). wBIS and cBIS were performed in 62 NS (33 m/29 f) and 30 HD patients (16 m/14 f) pre- and post-dialysis treatments to measure extracellular resistance and fluid volume (ECV) by the whole body and calf bioimpedance methods. Normalized calf resistivity (ρ(N)(,5)) was defined as resistivity at 5 kHz divided by the body mass index. The ratio of wECV to total body water (wECV/TBW) was calculated. Measurements were made at baseline (BL) and at DW(cBIS) following the progressive reduction of post-HD weight over successive dialysis treatments until the curve of calf extracellular resistance is flattened (stabilization) and the ρ(N)(,5) was in the range of NS. Blood pressures were measured pre- and post-HD treatment. ρ(N)(,5) in males and females differed significantly in NS. In patients, ρ(N)(,5) notably increased with progressive decrease in body weight, and systolic blood pressure significantly decreased pre- and post-HD between BL and DW(cBIS) respectively. Although wECV/TBW decreased between BL and DW(cBIS), the percentage of change in wECV/TBW was significantly less than that in ρ(N)(,5) (-5.21 ± 3.2% versus 28 ± 27%, p < 0.001). This establishes the use of ρ(N)(,5) as a new comparator allowing a clinician to incrementally monitor removal of extracellular fluid from patients over the course of dialysis treatments. The conventional whole body technique using wECV/TBW was less sensitive than the use of ρ(N)(,5) to measure differences in body hydration between BL and DW(cBIS).
22 January 2003 in Blood Purification
CKCharoen Kaitwatcharachai
The usefulness of regional bioimpedance analysis (RBIA) in determining the dry weight in dialysis patients is currently being investigated. The aim of this study was to evaluate the reproducibility of measurement of resistivity in the calf. Methods: Twenty-five normal subjects and 10 patients undergoing regular hemodialysis were studied. Four electrodes inserted into a blood pressure cuff were placed on the calf. Bioimpedance was continuously measured over 3- to 5-min periods (Xitron Hydra). After a resting period of 1 min, cuff pressure was increased to above the systolic blood pressure (SBP) for a few seconds to expel excess ECF fluid and then deflated. The effect on recordings of moving the electrodes 2 cm higher and then 2 cm lower than the normal position was studied in 8 normal subjects. In a second study of reproducibility, post-dialysis measurements were made twice in 10 patients who maintained the same post-dialysis target weight throughout the study period. Results: The mean resting resistivity (ρ₀) in normal subjects was 532.6 ± 95 Ω·cm rising to 583.9 ± 99.7 Ω·cm when cuff pressure was applied (ρp). The average values of ρ₀ and ρp in patients post-dialysis were 489 ± 74 and 537 ± 77 respectively showing that there were no significant differences in ρ₀ and ρp between normal subjects and patients post-dialysis. The mean values of change in resistivity when the electrodes were shifted between the lowest and highest positions on the calf were –3.66 ± 4.45 and –1.44 ± 3.82%, respectively. Repeat measurement of resistivity in patients post-dialysis varied by 2.04 ± 2.29% while post-dialysis body weight varied by 0.17 ± 0.47%. Conclusion: In this study, resistivity measurement by RBIA at the calf showed similar levels of fluid loading in patients post-dialysis as in normal subjects. This study also showed that change in electrode position resulted in a mean change in resistivity of <5% and repeated measurements showed a change in resistivity <3% while body weight changes were <0.2%. This technique appears to have an acceptable level of reproducibility for its application to the assessment of patient hydration.
1 March 2015 in Journal of Renal Nutrition