Venkata Narasimha Manyam

Venkata Narasimha Manyam

Auto-generated profile, based on publicly available information

Venkata Narasimha Manyam

Brookhaven National Laboratory

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2025 in Physical Review D
Verified
Journal Article
Open access
AAA. Abed Abud
A. Abed Abud
BAB. Abi
B. Abi
RAR. Acciarri
R. Acciarri
MAM. A. Acero
M. A. Acero
MAM. R. Adames
M. R. Adames
RZR. Zwaska
R. Zwaska
The determination of the direction of a stellar core collapse via its neutrino emission is crucial for the identification of the progenitor for a multimessenger follow-up. A highly effective method of reconstructing supernova directions within the Deep Underground Neutrino Experiment (DUNE) is introduced. The supernova neutrino pointing resolution is studied by simulating and reconstructing electron-neutrino charged-current absorption on Ar 40 and elastic scattering of neutrinos on electrons. Procedures to reconstruct individual interactions, including a newly developed technique called “brems flipping,” as well as the burst direction from an ensemble of interactions are described. Performance of the burst direction reconstruction is evaluated for supernovae happening at a distance of 10 kpc for a specific supernova burst flux model. The pointing resolution is found to be 3.4 degrees at 68% coverage for a perfect interaction-channel classification and a fiducial mass of 40 kton, and 6.6 degrees for a 10 kton fiducial mass respectively. Assuming a 4% rate of charged-current interactions being misidentified as elastic scattering, DUNE’s burst pointing resolution is found to be 4.3 degrees (8.7 degrees) at 68% coverage. Published by the American Physical Society 2025

14 November 2024 in Physical Review D
Verified
Journal Article
Open access
AAA. Abed Abud
A. Abed Abud
BAB. Abi
B. Abi
RAR. Acciarri
R. Acciarri
MAM. R. Adames
M. R. Adames
GAG. Adamov
G. Adamov
DCDUNE Collaboration
DUNE Collaboration
ProtoDUNE Single-Phase (ProtoDUNE-SP) is a 770-ton liquid argon time projection chamber that operated in a hadron test beam at the CERN Neutrino Platform in 2018. We present a measurement of the total inelastic cross section of charged kaons on argon as a function of kaon energy using 6 and 7 GeV / c beam momentum settings. The flux-weighted average of the extracted inelastic cross section at each beam momentum setting was measured to be 380 ± 26 mbarns for the 6 GeV / c setting and 379 ± 35 mbarns for the 7 GeV / c setting. Published by the American Physical Society 2024

1 June 2017
Verified
Conference Paper
Closed access
VMVenkata Narasimha Manyam
Venkata Narasimha Manyam
DPDang-Kien Germain Pham
Dang-Kien Germain Pham
CJChadi Jabbour
Chadi Jabbour
PDPatricia Desgreys
Patricia Desgreys
A memory polynomial (MP) based digital baseband predistorter for wideband base station RF power amplifiers is presented. The conventional memory polynomial based predistorter's inability to sufficiently improve the adjacent channel leakage ratio (ACLR) for high bandwidth signals is mitigated by using a linear FIR filter. The FIR filter compensates for the linear memory distortions and is employed prior to the memory polynomial predistorter (FIR-MP). The proposed technique is validated in simulations for 20 MHz and 80 MHz signals centered at 2 GHz. The PA models for the simulation are extracted from measurements carried out on a commercial 1W GaAs HBT PA. With considerably less number of coefficients, an ACLR improvement of at least 5.2 dB and 11.1 dB over the conventional MP DPD is obtained for 20 MHz and 80 MHz signals, respectively, and hence showing suitability for the adoption into small-cell base stations.

1 October 2017
Verified
Conference Paper
Closed access
PDPatricia Desgreys
Patricia Desgreys
VMVenkata Narasimha Manyam
Venkata Narasimha Manyam
KTKelly Tchambake
Kelly Tchambake
DPDang-Kien Germain Pham
Dang-Kien Germain Pham
CJChadi Jabbour
Chadi Jabbour
This paper focuses on wideband power amplifier predistortion for current and future communications standards such as LTE and 5G. As a matter of fact, the large bandwidth and the large dynamic range of exchanged signals in these standards make the predistortion task very challenging. To overcome these challenges, innovations and improvements are needed in the three main blocks of the predistortion system, i.e., modeling and estimation algorithms, the transmission path and the observation path. In this work, for each of these three blocks, the state of the art is briefly presented and solutions are proposed to contribute in achieving a low power wideband predistortion compatible with the 5G low power transmission cells.

9 December 2024 in IEEE Transactions on Circuits and Systems I: Regular Papers
Verified
Journal Article
Open access
PMPrashansa Mukim
Prashansa Mukim
GCGabriella A. Carini
Gabriella A. Carini
HCHucheng Chen
Hucheng Chen
GDGrzegorz W. Deptuch
Grzegorz W. Deptuch
SGShanshan Gao
Shanshan Gao
SRSergio Rescia
Sergio Rescia
This paper presents design details and measurement results of LArASIC, a front-end application specific integrated circuit (ASIC) designed for low-noise readout of charge signals generated in neutrino study experiments within liquid argon time projection chambers. LArASIC comprises of 16-channels of programmable charge amplification and pulse shaping stages that provide a voltage readout proportional to the input charge and was optimized for operation at liquid argon temperature, i.e., 89K. The chip was fabricated in a 180nm CMOS process. Measurements at liquid nitrogen temperature, i.e., 77K, indicate that the channel outputs have high linearity (INL <0.1%) within the operating range, an equivalent noise charge of 534 electrons for a peaking time of 1 $\mu $ s and a detector capacitance of 150pF, and a worst-case inter-channel cross-talk of 0.35%. The paper also presents design choices made in the process of migrating LArASIC to CHARMS, an ASIC to be fabricated in a 65nm process that includes all features provided by LArASIC, along with additional digital programmability for improved robustness and flexibility. CHARMS is intended for use in future high-energy physics experiments that require high-resolution charge or light readout with shorter pulse peaking times.

27 June 2018 in Analog Integrated Circuits and Signal Processing
Verified
Journal Article
Closed access
PDF file
VMVenkata Narasimha Manyam
Venkata Narasimha Manyam
DPDang-Kièn Germain Pham
Dang-Kièn Germain Pham
CJChadi Jabbour
Chadi Jabbour
PDPatricia Desgreys
Patricia Desgreys