Levi A. Gheber

Levi A. Gheber

Auto-generated profile, based on publicly available information

Levi A. Gheber

Avram and Stella Goldstein-Goren Department of Biotechnology Engineering, Ben-Gurion University of the Negev, Be'er-Sheva, Israel.

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 1998 in Biophysical Journal
Verified
Journal Article
Open access
PDF file
JHJeeseong Hwang
Jeeseong Hwang
LGLevi A. Gheber
Levi A. Gheber
LMLeonid Margolis
Leonid Margolis
MEMichael Edidin
Michael Edidin
Near-field scanning optical microscopy (NSOM) uses the near-field interaction of light from a sharp fiber-optic probe with a sample of interest to image surfaces at a resolution beyond the diffraction limit of conventional optics. We used NSOM to image fluorescently labeled plasma membranes of fixed human skin fibroblasts, either dried or in buffer. A patchy distribution of a fluorescent lipid analog suggestive of lipid domains was observed in the fixed, dried cells. The sizes of these patches were consistent with the sizes of domains implied by fluorescence photobleaching recovery measurements. Patches of fluorescent lipid analog were not spatially correlated with patches of transmembrane proteins, HLA class I molecules labeled with fluorescent antibody; the patchiness of the HLA class I molecules was on a smaller scale and was not localized to the same regions of membrane as the lipid analog. Sizes of HLA patches were deduced from a two-dimensional spatial autocorrelation analysis of NSOM images that resolved patches with radii of ∼70 and ∼600nm on fixed, dried cells labeled with IgG and 300–600nm on cells labeled with Fab and imaged in buffer. The large-size patches were also resolved by far-field microscopy. Both the spatial autocorrelation analysis and estimates from fluorescence intensity indicate that the small patches seen on fixed, dried cells contain ∼25–125 HLA-I molecules each.

1 March 1994 in Journal of the American Chemical Society
Verified
Journal Article
Closed access
MHMichal Hershfinkel
Michal Hershfinkel
LGL. A. Gheber
L. A. Gheber
VVV. Volterra
V. Volterra
JHJ. L. Hutchison
J. L. Hutchison
LML. Margulis
L. Margulis
RTR. Tenne
R. Tenne

28 October 2019 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
PDF file
PRPaulina Ximena Medina Rangel
Paulina Ximena Medina Rangel
EMElena Moroni
Elena Moroni
Franck MerlierFranck Merlier
Franck Merlier
LGLevi A. Gheber
Levi A. Gheber
RVRazi Vago
Razi Vago
Karsten HauptKarsten Haupt
Karsten Haupt

18 March 2010 in Inorganic Chemistry
Verified
Journal Article
Closed access
ETEmiliano Tamanini
Emiliano Tamanini
KFKevin Flavin
Kevin Flavin
MMMajid Motevalli
Majid Motevalli
SPSilvia Piperno
Silvia Piperno
LGLevi A. Gheber
Levi A. Gheber
MWMichael Watkinson
Michael Watkinson

25 June 2015 in Scientific Reports
Verified
Journal Article
Open access
DBDaniel Blumenthal
Daniel Blumenthal
LGLeo Goldstien
Leo Goldstien
MEMichael Edidin
Michael Edidin
LGLevi A. Gheber
Levi A. Gheber
The original approach to calculating diffusion coefficients of a fluorescent probe from Fluorescence Recovery After Photobleaching (FRAP) measurements assumes bleaching with a circular laser beam of a Gaussian intensity profile. This method was used without imaging the bleached cell. An empirical equation for calculating diffusion coefficients from a rectangular bleaching geometry, created in a confocal image, was later published, however a single method allowing the calculation of diffusion coefficients for arbitrary geometry does not exist. Our simulation approach allows computation of diffusion coefficients regardless of bleaching geometry used in the FRAP experiment. It accepts a multiple-frame TIFF file, representing the experiment as input and simulates the (pure) diffusion of the fluorescent probes (2D random walk) starting with the first post-bleach frame of the actual data. It then fits the simulated data to the real data and extracts the diffusion coefficient. We validate our approach using a well characterized diffusing molecule (DiIC18) against well-established analytical procedures. We show that the algorithm is able to calculate the absolute value of diffusion coefficients for arbitrary bleaching geometries, including exaggeratedly large ones. It is provided freely as an ImageJ plugin and should facilitate quantitative FRAP measurements for users equipped with standard fluorescence microscopy setups.

30 July 2003 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
HTHesham Taha
Hesham Taha
Robert MarksRobert Marks
Robert Marks
LGLevi A. Gheber
Levi A. Gheber
IRIttay Rousso
Ittay Rousso
JNJohn Newman
John Newman
ALAaron Lewis
Aaron Lewis
We demonstrate the direct printing of proteins on a surface using a cantilevered nanopipette as the probe of a scanned probe microscope. Protein features as small as ∼200 nm were directly delivered through the ∼100 nm aperture of the nanopipette by simply contacting the probe with any surface. This allows for the direct connection of this methodology to standard separation techniques so that multiple proteins can be printed through one nanopipette at different locations in ambient conditions.