Samuel Huaquisto Cáceres

Samuel Huaquisto Cáceres

Auto-generated profile, based on publicly available information

Samuel Huaquisto Cáceres

Escuela Profesional de Ingeniería Civil, Universidad Nacional del Altiplano de Puno

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2018 in Revista de Investigaciones Altoandinas - Journal of High Andean Research
Verified
Journal Article
Open access
SCSamuel Huaquisto Cáceres
Samuel Huaquisto Cáceres
GQGermán Belizario Quispe
Germán Belizario Quispe
Utilización de la ceniza volante en la dosificación del concreto como sustituto del cemento

2 November 2023 in Materiales de Construcción
Verified
Journal Article
Open access
PDF file
SCSamuel Huaquisto Cáceres
Samuel Huaquisto Cáceres
DQDiana Karen Pari Quispe
Diana Karen Pari Quispe
RMRafael Arnold Cruz Maron
Rafael Arnold Cruz Maron
The energy deficiency in rural housing in the Andes of Peru is recurrent. In this context, local and low environmental impact materials present an opportunity. This research evaluated the properties of five panels composed of totora and gypsum for ceiling applications. Firstly, the physical and durability properties were obtained. Then, impact and fire resistance were evaluated. Finally, thermoacoustic properties were assessed. The results showed a moisture level of 10.25%, water absorption of 354.85% which is considered high, and a dry density of 292.84 kg/m3. Adequate durability to fungus with resin on both sides. The panels’ fire resistance is superior to 60 minutes, with a safe impact criterion for 10 N and a functionality criterion for 5 N. The average values for the panels were 0.061 W/m·K for thermal insulation and 0.54 for NRC. Therefore, it is possible to produce an insulating material for thermoacoustic improvement.

19 July 2022 in DYNA
Verified
Journal Article
Open access
PDF file
SHSamuel Huaquisto-Cáceres
Samuel Huaquisto-Cáceres
EHEdgar Vidal Hurtado-Chávez
Edgar Vidal Hurtado-Chávez
ICIsabel Griscelda Chambilla-Flores
Isabel Griscelda Chambilla-Flores
KBKatia Natalia Barrientos-Paredes
Katia Natalia Barrientos-Paredes
El objetivo del estudio es analizar el nivel de educación y ética ambiental en los programas de ingeniería civil para proponer contenidos transversales dentro del currículo. Para evaluar la presencia del tema ambiental se aplicó un cuestionario con escala Likert a 260 estudiantes y escala dicotómica a 42 profesores y directivos de las universidades de la región Puno. Los resultados indican que los estudiantes presentan un nivel ético ambiental medio en conocimientos y habilidades mientras que en actitudes y valores se ha presentado un nivel alto. Respecto a la aplicación del tema ambiental por parte de los profesores se presenta un nivel medio en los ámbitos físico, pedagógico y didáctico y un nivel alto en el ámbito académico; en consecuencia, en necesario establecer políticas ambientales de manera explícita en los planes estratégicos y los currículos de estudio para que el futuro profesional asuma su compromiso ambiental al momento de ejecutar proyectos de infraestructura civil.

30 June 2014 in Revista Hábitat Sustentable
Verified
Journal Article
Open access
PDF file
DPDiana Karen Pari-Quispe
Diana Karen Pari-Quispe
JSJoára Cronemberger-Ribeiro Silva
Joára Cronemberger-Ribeiro Silva
SHSamuel Huaquisto-Cáceres
Samuel Huaquisto-Cáceres
HCHugo Anselmo Ccama-Condori
Hugo Anselmo Ccama-Condori
LALeyda Cinthia Aza-Medina
Leyda Cinthia Aza-Medina
The objective of this work was to conduct a field study to determine the thermal perception of users of vernacular housing in the cold climate of the Peruvian High Andean region. The units analyzed were houses built by the Uro community using “totora” (bulrush reeds). The field study characterized the dwelling’s thermal performance, determined body surface area and clothing insulation, assessed thermal sensation, preference, and acceptability, determined personal adjustment strategies, and calculated the neutral temperature. Seventy-eight valid surveys were collected in two periods (summer and winter). The results reveal that the dwelling’s users are uncomfortable. The preference points to warmer and drier environments. The neutral temperature was 19.62 ºC in summer and 21.98 ºC in winter. However, the inhabitants had the expectation that the environment could be thermally improved with more insulation.

22 May 2021 in REVISTA VERITAS ET SCIENTIA - UPT
Verified
Journal Article
Open access
PDF file
SCSamuel Huaquisto Cáceres
Samuel Huaquisto Cáceres
IFIsabel Griscelda Chambilla Flores
Isabel Griscelda Chambilla Flores
La contaminación sonora durante el proceso constructivo de un pavimento rígido es un factor ambiental que incide negativamente en la calidad de vida de los trabajadores y la población aledaña, en tal sentido, el objetivo del estudio fue analizar los niveles de ruido emitidos por el equipo mecánico utilizado en la construcción de vías urbanas a fin de proponer protección auditiva a los trabajadores. Los resultados indican que el equipo mecánico utilizado en la construcción de vías del distrito de Desaguadero emite niveles de ruido desde 69,6±5,1 dBA a 98,4±3,8 dBA, siendo los equipos livianos los más influyentes. La tarea más ruidosa es la del corte del concreto en pavimento que presenta un nivel de ruido de 87,88±3,2 dBA medido a un radio de cinco metros de la fuente. En conclusión, el equipo mecánico utilizado en la construcción de vías emite niveles de ruido que pueden incidir en la salud de la población y en el desempeño de los trabajadores, recomendándose el uso de protectores auditivos de un nivel mínimo NRR 15 dB para operadores de equipo mecánico pesado y NRR 25 dB para equipos livianos

1 August 2025 in Revista ingeniería de construcción
Verified
Journal Article
Open access
PDF file
LRLeonel Roy López Ramos
Leonel Roy López Ramos
DODiego Jenko Crespo Ortega
Diego Jenko Crespo Ortega
SCSamuel Huaquisto Cáceres
Samuel Huaquisto Cáceres
ASAlberto Ccama Sullca
Alberto Ccama Sullca
RLRoberto Mariano García Loayza
Roberto Mariano García Loayza
DMDante Salas Mercado
Dante Salas Mercado
Self-constructed homes, commonly built without technical supervision, often rely on empirically prepared concrete mixes that result in high variability and substandard mechanical performance. This study evaluated the effect of incorporating Bacillus subtilis and Bacillus cereus into such non-standard concrete to improve its compressive strength. Two widely used field dosages were identified through surveys with master builders, reaching compressive strengths of 4.98 MPa and 11.77 MPa at 28 days, both below the 17 MPa minimum required by building codes. These mixes were replicated as controls, and the bacterial strains previously isolated and cultured were added at concentrations of 10³, 10⁵, and 10⁷ CFU/mL. The incorporation of Bacillus subtilis at 10³ CFU/mL improved compressive strength by 6.57%, while Bacillus cereus at 10⁷ CFU/mL achieved a 36.91% increase, reaching 16.11 MPa. This improvement is attributed to calcium carbonate precipitation via microbial biomineralization. Notably, Bacillus cereus remained active at ambient curing temperatures near 10 °C, typical of high-altitude environments, and proved more effective under such conditions. These findings highlight the potential of microbial additives, particularly Bacillus cereus, as a low-cost and context-adapted solution to enhance concrete performance in self-constructed homes.