23 October 2023 in Advanced Science
Neural interfaces for stable access to the spinal cord (SC) electrical activity can benefit patients with motor dysfunctions. Invasive high‐density electrodes can directly extract signals from SC neuronal populations that can be used for the facilitation, adjustment, and reconstruction of motor actions. However, developing neural interfaces that can achieve high channel counts and long‐term intraspinal recording remains technically challenging. Here, a biocompatible SC hyperflexible electrode array (SHEA) with an ultrathin structure that minimizes mechanical mismatch between the interface and SC tissue and enables stable single‐unit recording for more than 2 months in mice is demonstrated. These results show that SHEA maintains stable impedance, signal‐to‐noise ratio, single‐unit yield, and spike amplitude after implantation into mouse SC. Gait analysis and histology show that SHEA implantation induces negligible behavioral effects and Inflammation. Additionally, multi‐unit signals recorded from the SC ventral horn can predict the mouse's movement trajectory with a high decoding coefficient of up to 0.95. Moreover, during step cycles, it is found that the neural trajectory of spikes and low‐frequency local field potential (LFP) signal exhibits periodic geometry patterns. Thus, SHEA can offer an efficient and reliable SC neural interface for monitoring and potentially modulating SC neuronal activity associated with motor dysfunctions.
13 April 2026 in Nature Communications
Monitoring neural population activity at single-cell resolution is essential for fundamental research and clinical innovation. However, translating advanced recording techniques from animal models to humans remains a challenge. Flexible neural electrodes have emerged as powerful tools for large-scale single-unit recordings due to their biocompatibility and high recording density. Here, we demonstrate reliable, high-density single-unit recordings during intraoperative procedures in human patients using ultra-Flexible Implantable Neural Electrode (uFINE) arrays. The uFINE array exhibited sufficient mechanical robustness to maintain structural integrity throughout surgical operations. We successfully recorded 719 single units from 11 patients, with up to 135 single units simultaneously recorded. The flexibility of uFINE array minimized signal disturbances from brain pulsations, enabling stable and continuous single-unit detection. Stimulus and response tuning were observed at the level of individual neurons in awake patients.