1 October 2022 in Circulation: Arrhythmia and Electrophysiology
Background: Previous animal studies have shown no significant vascular injury from pulsed electrical field (PEF) ablation. We sought to assess the effect of PEF on swine coronary arteries. Methods: We performed intracoronary and epicardial (near the coronary artery) PEF ablations in swine pretreated with dual antiplatelet and antiarrhythmic therapy. Intracoronary PEF was delivered using MapiT catheters (Biotronik, Berlin), whereas epicardial PEF was delivered using EPT catheters (Boston Scientific, MA). PEF pulse duration was microseconds (Nanoknife 3.0, Angio Dynamics, NY) or nanoseconds (CellFX, Pulse Biosciences, CA). Results: We performed 39 intracoronary ablations in 10 swine and 20 epicardial-pericoronary ablations in 4 separate swine. Intracoronary PEF was delivered at higher energy compared with epicardial PEF (46 [interquartile range, IQR 20–85] J versus 10 [IQR 10–11] J, P < 0.01). Reversible coronary spasm occurred in 49% intracoronary ablations and 45% epicardial ablations ( P =0.80). At the end study, fixed coronary stenosis was demonstrated in 44% intracoronary ablations (80% for microsecond PEF and 18% for nanosecond PEF) and 0% epicardial ablations. Visible hemorrhagic and/or fibrotic myocardial lesions were observed at necropsy with similar frequency between intracoronary and epicardial PEF (45% versus 50%, P =0.70). Nanosecond PEF (49 ablations in 11 swine), when compared with microsecond PEF (10 intracoronary ablations in 3 swine), resulted in lower energy delivery (21 [IQR 10–46] J versus 129 [IQR 24–143] J, P =0.03) and less incidence of fixed coronary stenosis (18% versus 80%, P =0.04). Conclusions: In the swine model, intracoronary PEF resulted both in significant coronary spasm and fixed coronary stenosis. Epicardial PEF, delivered at lower energy, resulted in reversible spasm but no fixed coronary stenosis.
1 October 2021 in Circulation: Arrhythmia and Electrophysiology
Background: Rigorous study of ventricular fibrillation (VF) is not feasible in humans. The spatiotemporal characteristics of prolonged VF remain undefined, limiting our understanding of this lethal rhythm. Methods: VF was mapped in 4 canines. The endocardial and epicardial left ventricle (LV) and right ventricle (RV) were sequentially mapped at 0 to 15, 15 to 30, 30 to 45, and 45 to 60 minutes post-induction. Ten consecutive beats were used to determine the average cycle length and regularity index of ventricular and His-Purkinje system signals in discrete regions during each time interval. Results: Average VF time was 58±12 minutes. The shortest ventricular cycle length was present in the RV apical region (70±10 msec) at 0 to 15 minutes and at 15 to 30 minutes (89±31 msec) and LV apical region at 45 to 60 minutes (242±163 msec). The His-Purkinje system cycle length was the shortest at the RV outflow tract (75±3 msec) at 0 to 15 minutes, RV inflow and free wall (89±12 msec) at 15 to 30 minutes, LV apical region (83±14 msec) at 30 to 45 minutes, and inferior and inferolateral LV (145±23 msec) at 45 to 60 minutes. Regularity index was the highest in the RV inflow and free wall (78%) at 0 to 15 minutes, RV apical region (86%) at 15 to 30 minutes, LV septum and epicardial anterior RV (80%) at 30 to 45 minutes, and anterior and anterolateral LV (75%) at 45 to 60 minutes. Conclusions: These data suggest significant regional changes in electrical activity throughout VF in canines. A transition of fastest electrical activity from RV to LV apical regions across VF was observed. These novel insights of the temporal and spatial changes of VF merit further evaluation in diseased hearts to assess for reproducibility of findings.