A. Arbat

A. Arbat

Auto-generated profile, based on publicly available information

A. Arbat

University of Barcelona

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 June 2009 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
AAA. Arbat
A. Arbat
EEE. Edqvist
E. Edqvist
RCR. Casanova
R. Casanova
JBJ. Brufau
J. Brufau
JCJoan Canals
Joan Canals
Angel DiéguezAngel Diéguez
Angel Diéguez

23 October 2010 in Procedia Engineering
Verified
Journal Article
Open access
PDF file
AAA. Arbat
A. Arbat
AMAlbert Comerma Montells
Albert Comerma Montells
JTJ. Trenado
J. Trenado
David GasconDavid Gascon
David Gascon
AVAnna Vilà
Anna Vilà
ADA. Diègueza
A. Diègueza
This work presents a comparison between high voltage 0.35 μm and high integration 0.13 μm commercially available CMOS technologies to fabricate an APD array for tracking high energy particles. Size, speed and noise are fixed for the particular collider. The characterization of both technologies shows that neither of them satisfies all the imposed constrains. The high voltage technology has a low dark count rate related to the low trap concentration but the sensor is too slow. The high integration technology generates fast sensors with high dark count rates. It is concluded that in order to decrease the amount of data to save and hence memory it would be recommended the use of the 0.35 μm-HV technology in front of the 0.13 μm technology.

1 January 2011 in Journal of Instrumentation
Verified
Journal Article
Closed access
EVEva Vilella
Eva Vilella
AAA Arbat
A Arbat
AMAlbert Comerma Montells
Albert Comerma Montells
JTJ Trenado
J Trenado
Oscar AlonsoOscar Alonso
Oscar Alonso
Angel DiéguezAngel Diéguez
Angel Diéguez

1 December 2011 in Sensor Letters
Verified
Journal Article
Closed access
EVEva Vilella
Eva Vilella
AAA. Arbat
A. Arbat
Oscar AlonsoOscar Alonso
Oscar Alonso
AMAlbert Comerma Montells
Albert Comerma Montells
JTJ. Trenado
J. Trenado
Angel DiéguezAngel Diéguez
Angel Diéguez
Avalanche photodiodes operated in the Geiger mode present very high intrinsic gain and fast time response, which make the sensor an ideal option for those applications in which detectors with high sensitivity and velocity are required. Moreover they are compatible with conventional CMOS technologies, allowing sensor and front-end electronics integration within the pixel cell. Despite these excellent qualities, the photodiode suffers from high intrinsic noise, which degrades the performance of the detector and increases the memory area to store the total amount of information generated. In this work, a new front-end circuit that allows low reverse bias overvoltage sensor operation to reduce the noise in Geiger mode avalanche photodiode pixel detectors is presented. The proposed front-end circuit also enables to operate the sensor in the gated acquisition mode to further reduce the noise. Experimental characterization of the fabricated pixel with the conventional HV-AMS 0.35 μm technology is also presented in this article.

1 December 2006
Verified
Conference Paper
Closed access
AAA. Arbat
A. Arbat
Angel DiéguezAngel Diéguez
Angel Diéguez
JSJ. Samitier
J. Samitier
A low power successive approximation analog-to-digital converter is presented operating at 1.2 V supply. The circuit has been designed in a 0.13 μm standard CMOS technology. The power consumption while converting is 13 μW, and in standby mode the power is reduced to 5.8 μW. The resolution is programmable between 1 to 8 bits. It can work from 500 Hz up to 50 kHz clock frequencies.

1 September 2005
Verified
Conference Paper
Closed access
RCR. Casanova
R. Casanova
Angel DiéguezAngel Diéguez
Angel Diéguez
JLJ. Lacort
J. Lacort
AAA. Arbat
A. Arbat
JSJ. Samitier
J. Samitier
OSO. Steinmetz
O. Steinmetz
A specific integrated controller for a wireless and autonomous microrobot of 1 cm 3 is presented. The microrobot is equipped with an atomic force microscopy (AFM) probe, a syringe or a gripper to develop cooperative tasks in biological experiences. Its main functionality and the controller design is focused on nanomicroscopy and cellular manipulation. The circuit manages the microrobot locomotion unit and its tools with nanometric resolution.