Amneet Sandhu

Amneet Sandhu

Auto-generated profile, based on publicly available information

Amneet Sandhu

University of Colorado

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2022 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
PDF file
JGJack R. Griffiths
Jack R. Griffiths
UNUdi Nussinovitch
Udi Nussinovitch
Jackson J. LiangJackson J. Liang
Jackson J. Liang
RSRichard Sims
Richard Sims
ZYZachary T. Yoneda
Zachary T. Yoneda
DNDuy T Nguyen
Duy T Nguyen
Background: Data on atrial fibrillation (AF) ablation and outcomes are limited in patients with congenital heart disease (CHD). We aimed to investigate the characteristics of patients with CHD presenting for AF ablation and their outcomes. Methods: A multicenter, retrospective analysis was performed of patients with CHD undergoing AF ablation between 2004 and 2020 at 13 participating centers. The severity of CHD was classified using 2014 Pediatric and Congenital Electrophysiology Society/Heart Rhythm Society guidelines. Clinical data were collected. One-year complete procedural success was defined as freedom from atrial tachycardia or AF in the absence of antiarrhythmic drugs or including previously failed antiarrhythmic drugs (partial success). Results: Of 240 patients, 127 (53.4%) had persistent AF, 62.5% were male, and mean age was 55.2±13.3 years. CHD complexity categories included 147 (61.3%) simple, 68 (28.3%) intermediate, and 25 (10.4%) severe. The most common CHD type was atrial septal defect (n=78). More complex CHD conditions included transposition of the great arteries (n=14), anomalous pulmonary veins (n=13), tetralogy of Fallot (n=8), cor triatriatum (n=7), single ventricle physiology (n=2), among others. The majority (71.3%) of patients had trialed at least one antiarrhythmic drug. Forty-six patients (22.1%) had reduced systemic ventricular ejection fraction <50%, and mean left atrial diameter was 44.1±8.2 mm. Pulmonary vein isolation was performed in 227 patients (94.6%); additional ablation included left atrial linear ablations (40%), complex fractionated atrial electrogram (19.2%), and cavotricuspid isthmus ablation (40.8%). One-year complete and partial success rates were 45.0% and 20.5%, respectively, with no significant difference in the rate of complete success between complexity groups. Overall, 38 patients (15.8%) required more than one ablation procedure. There were 3 (1.3%) major and 13 (5.4%) minor procedural complications. Conclusions: AF ablation in CHD was safe and resulted in AF control in a majority of patients, regardless of complexity. Future work should address the most appropriate ablation targets in this challenging population.

1 December 2022 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
ASAmneet Sandhu
Amneet Sandhu
PVPaul D. Varosy
Paul D. Varosy
CDChengan Du
Chengan Du
RARyan G. Aleong
Ryan G. Aleong
ATAlexis Z. Tumolo
Alexis Z. Tumolo
PHPaul L. Hess
Paul L. Hess
Background: Left atrial appendage occlusion is an important alternative to anticoagulation in select patients with nonvalvular atrial fibrillation. Trends in real-world device sizing and associated short-term complications have not been characterized. Methods: Using the National Cardiovascular Data Left Atrial Appendage Occlusion (NCDR LAAO) Registry, patients who underwent left atrial appendage occlusion with a Watchman 2.5 device from January 1, 2016, to June 30, 2020, were identified. Patients were stratified by device size based on left atrial appendage orifice size, and categorized as receiving a device that was undersized, oversized, or per manufacturer recommendation. Relationships between device sizing and short-term outcomes, including pericardial effusion, device embolism, and significant leak, were assessed. Results: Of the 68 456 patients, 6539 (10.5%) of patients received undersized devices, 17 791 (26.0%) according to manufacturer recommendations, and 44 126 (64.4%) received an oversized device. The 27-mm device was most commonly deployed [21 736 (31.8%)], whereas the smallest and largest devices (21 and 33 mm) were least commonly deployed [7695 (11.2%) and 9077 (13.3%), respectively]. Compared with manufacturer recommended sizing, there was no difference in the odds of pericardial effusion for either undersized (1.048 [95% CI‚ 0.801–1.372]; P= 0.733) or oversized (1.101 [95% CI‚ 0.933–1.298]; P= 0.254) devices. Similarly, relative to manufacturer recommended sizing, the odds of a composite adverse outcome of device migration or embolization and significant peridevice leak at 45 days were similar among undersized devices (1.030 [95% CI‚ 0.735–1.444]; P= 0.863) and favorable for oversized devices (0.701 [95% CI‚ 0.561–0.876]; P= 0.002) devices, primarily driven by lower odds of leak. Selection of oversized devices increased significantly over the study period (from 60.3% in 2016 to 66.0% in 2020; P <0.001). Conclusions: Among patients undergoing left atrial appendage occlusion with the first-generation Watchman device, receipt of oversized devices was common and increased over time. The high prevalence of oversizing was associated with lower odds of significant leak or device embolization without increased odds of other adverse events.

9 October 2021 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Open access
PDF file
BWBryan C. Wallace
Bryan C. Wallace
JJJacqueline Jones
Jacqueline Jones
FMFrederick A. Masoudi
Frederick A. Masoudi
CNCarolyn T. Nowels
Carolyn T. Nowels
PVPaul Varosy
Paul Varosy
DMDaniel D. Matlock
Daniel D. Matlock
Background: Using DAs for preference‐sensitive decisions is an evidence‐based way to improve patient‐centered decisions. Reimbursement mandates have increased the need for DAs in ICD care, although none have been formally evaluated. The objectives were to develop and pilot implantable cardioverter‐defibrillator (ICD) decision aids (DAs) for patients considering primary prevention ICDs.Methods: Development Phase: An expert panel, including patients and physicians, iteratively developed four DAs: a one‐page Option GridTM conversation aid, a four‐page in‐depth paper tool, a 17‐minute video, and an interactive website. Trial Phase: At three sites, patients with heart failure who were eligible for primary prevention ICDs were randomly assigned 2:1 to intervention (received DAs) or control (usual care). We conducted a mixed‐methods evaluation exploring acceptability and feasibility.Results: Twenty‐one eligible patients enrolled (15 intervention). Most intervention participants found the DAs to be unbiased (67%), helpful (89%), and would recommend them to others (100%). The pilot was feasible at all sites; however, using clinic staff to identify eligible patients was more efficient than chart review. Although the main goals were to measure acceptability and feasibility, intervention participants trended towards increased concordance between longevity values and ICD decisions (71% concordant vs. 29%, p = .06). Participants preferred the in‐depth paper tool and video DAs. Access to a nurse during the decision‐making window encouraged questions and improved participant‐perceived confidence.Conclusions: Participants felt the DAs provided helpful, balanced information that they would recommend to other patients. Further exploration of this larger context of DA use and strategies to promote independent use related to electrophysiology (EP) visits are needed.

1 July 2024 in Circulation: Cardiovascular Quality and Outcomes
Verified
Journal Article
Closed access
DMDaniel D. Matlock
Daniel D. Matlock
LJLarry R. Jackson
Larry R. Jackson
ASAmneet Sandhu
Amneet Sandhu
LSLaura D. Scherer
Laura D. Scherer

12 February 2025 in JACC: Clinical Electrophysiology
Verified
Journal Article
Closed access
SSSarah Slaven
Sarah Slaven
LGLohit Garg
Lohit Garg
RSRafay Sabzwari
Rafay Sabzwari
CBChristopher Barrett
Christopher Barrett
ATAlexis Tumolo
Alexis Tumolo
MRMichael Rosenberg
Michael Rosenberg

1 October 2019 in JACC: Clinical Electrophysiology
Verified
Journal Article
Closed access
JEJustin A. Edward
Justin A. Edward
MZMatthew M. Zipse
Matthew M. Zipse
CTChristine Tompkins
Christine Tompkins
PVPaul D. Varosy
Paul D. Varosy
ASAmneet Sandhu
Amneet Sandhu
DNDuy T Nguyen
Duy T Nguyen