16 April 2004 in The Journal of the Acoustical Society of America
The ultrasonic axial transmission technique, used to assess cortical shells of long bones, is investigated using numerical simulations based on a three-dimensional (3D) finite difference code. We focus our interest on the effects of 3D cortical bone geometry (curvature, cortical thickness), anisotropy, and microporosity on speed of sound (SOS) measurements for different frequencies in the MHz range. We first show that SOS values measured on tubular cortical shells are identical to those measured on cortical plates of equal thickness. Anisotropy of cortical bone is then shown to have a major impact on SOS measurement as a function of cortical thickness. The range of SOS values measured on anisotropic bone is half the range found when bone is considered isotropic. Dependence of thickness occurs for cortical shell thinner than in anisotropic bone wavelength in bone), whereas it occurs for cortical shell thinner than when anisotropy is neglected. Sensitivity of SOS along the bone axis to intracortical microporosity is shown to be approximately −20 m s−1 per percent of porosity. Using homogenized porous bone, we finally show that the cortical depth that contributes to lateral wave SOS measurement is approximately 1–1.5 mm for frequencies ranging from 500 kHz to 2 MHz under classical in vivo measurement conditions.
1 July 2002 in The Journal of the Acoustical Society of America
In recent years, quantitative ultrasound (QUS) has played an increasing role in the assessment of bone status. The axial transmission technique allows to investigate skeletal sites such as the cortical layer of long bones (radius, tibia), inadequate to through-transmission techniques. Nevertheless, the type of propagation involved along bone specimens has not been clearly elucidated. Axial transmission is investigated here by means of two-dimensional simulations at 1 MHz. We focus our interest on the apparent speed of sound (SOS) of the first arriving signal (FAS). Its dependence on the thickness of the plate is discussed and compared to previous work. Different time criteria are used to derive the apparent SOS of the FAS as a function of source–receiver distance. Frequency-wave number analysis is performed in order to understand the type of propagation involved. For thick plates longitudinal wavelength in bone), and for a limited range of source–receiver distances, the FAS corresponds to the lateral wave. Its velocity equals the longitudinal bulk velocity of the bone. For plate thickness less than some plate modes contribute to the FAS, and the apparent SOS decreases with the thickness in a way that depends on both the time criterion and on the source–receiver distance. The FAS corresponds neither to the lateral wave nor to a single plate mode. For very thin plates the apparent SOS tends towards the velocity of the lowest order symmetrical vibration mode Lamb mode).
1 May 1998 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Measurement of ultrasonic attenuation and velocity in cancellous bone are being applied to aid diagnosis of women with high fracture risk due to osteoporosis. However, velocity dispersion in cancellous bone has received little attention up to now. The overall goal of this research was to characterize the velocity dispersion of human cancellous bone based on a spectral analysis of ultrasound transmitted through the bone specimens. We have followed a systematic approach, beginning with the investigation of a test material, moving on to the investigation of bone specimens. Particular attention is given to diffraction effect, a potential source of artifacts. Parametric images of phase velocity (measured at the center frequency of the pulse spectrum), slope of attenuation coefficient (dB/cm/MHz) and velocity dispersion were obtained by scanning 15 bone specimens. We have demonstrated that the diffraction effect is negligible in the useful frequency bandwidth, and that the ultrasonic parameters reflect intrinsic acoustic properties of bone tissue. The measured attenuation showed approximately linear behavior over the frequency range 200 to 600 kHz. Velocity dispersion of cancellous bone in the frequency range 200 to 600 kHz was unexpectedly found to be either negative or positive and not correlated with the slope of attenuation coefficient. There was a highly significant correlation between the slope of attenuation coefficient and phase velocity at the center frequency of the spectrum. This behavior contrasts with other biological or nonbiological materials where the local form of the Kramers-Kronig relationship provides accurate prediction of velocity dispersion from the experimental frequency dependent-attenuation for unbounded waves.
1 March 2011 in Ultrasound in Medicine & Biology
8 November 2005 in Physics in Medicine & Biology
Three-dimensional numerical simulations of ultrasound transmission were performed through 31 trabecular bone samples measured by synchrotron microtomography. The synchrotron microtomography provided high resolution 3D mappings of bone structures, which were used as the input geometry in the simulation software developed in our laboratory. While absorption (i.e. the absorption of ultrasound through dissipative mechanisms) was not taken into account in the algorithm, the simulations reproduced major phenomena observed in real through-transmission experiments in trabecular bone. The simulated attenuation (i.e. the decrease of the transmitted ultrasonic energy) varies linearly with frequency in the MHz frequency range. Both the speed of sound (SOS) and the slope of the normalized frequency-dependent attenuation (nBUA) increase with the bone volume fraction. Twenty-five out of the thirty-one samples exhibited negative velocity dispersion. One sample was rotated to align the main orientation of the trabecular structure with the direction of ultrasonic propagation, leading to the observation of a fast and a slow wave. Coupling numerical simulation with real bone architecture therefore provides a powerful tool to investigate the physics of ultrasound propagation in trabecular structures. As an illustration, comparison between results obtained on bone modelled either as a fluid or a solid structure suggested the major role of mode conversion of the incident acoustic wave to shear waves in bone to explain the large contribution of scattering to the overall attenuation.