22 February 2024 in Physical Review Letters
We report on laser cooling of a large fraction of positronium (Ps) in free flight by strongly saturating the transition with a broadband, long-pulsed 243 nm alexandrite laser. The ground state Ps cloud is produced in a magnetic and electric field-free environment. We observe two different laser-induced effects. The first effect is an increase in the number of atoms in the ground state after the time Ps has spent in the long-lived states. The second effect is one-dimensional Doppler cooling of Ps, reducing the cloud’s temperature from 380(20) to 170(20) K. We demonstrate a 58(9)% increase in the fraction of Ps atoms with .
4 April 2025 in Science Advances
Primary goal of the AEḡIS experiment is to precisely measure the free fall of antihydrogen within Earth’s gravitational field. To this end, cold (≈50 K) antihydrogen will traverse a two-grid moiré deflectometer before annihilating onto a position-sensitive detector, which shall determine the vertical position of the annihilation vertex relative to the grids with micrometric accuracy. Here, we introduce a vertexing detector based on a modified mobile camera sensor and experimentally demonstrate that it can measure the position of antiproton annihilations within μm, a 35-fold improvement over the previous state of the art for real-time antiproton vertexing. These methods are directly applicable to antihydrogen. Moreover, the sensitivity to light of the sensor enables in situ calibration of the moiré deflectometer, substantially reducing systematic errors. This sensor emerges as a breakthrough technology toward the AEḡIS scientific goals and will constitute the basis for the development of a large-area detector for conducting antihydrogen gravity measurements.
20 November 2018 in The European Physical Journal D
1 August 2024 in Review of Scientific Instruments
Modern physics experiments are frequently very complex, relying on multiple simultaneous events to happen in order to obtain the desired result. The experiment control system plays a central role in orchestrating the measurement setup: However, its development is often treated as secondary with respect to the hardware, its importance becoming evident only during the operational phase. Therefore, the AEḡIS (Antimatter Experiment: Gravity, Interferometry, Spectroscopy) collaboration has created a framework for easily coding control systems, specifically targeting atomic, quantum, and antimatter experiments. This framework, called Total Automation of LabVIEW Operations for Science (TALOS), unifies all the machines of the experiment in a single entity, thus enabling complex high-level decisions to be taken, and it is constituted by separate modules, called MicroServices, that run concurrently and asynchronously. This enhances the stability and reproducibility of the system while allowing for continuous integration and testing while the control system is running. The system demonstrated high stability and reproducibility, running completely unsupervised during the night and weekends of the data-taking campaigns. The results demonstrate the suitability of TALOS to manage an entire physics experiment in full autonomy: being open-source, experiments other than the AEḡIS experiment can benefit from it.
21 July 2022 in Physical Review B
Silicon nanochannel plates (NCPs) are employed in a variety of experiments as sources of cold positronium (Ps) via positron to Ps conversion. Despite the widespread use of NCPs, no comprehensive model of the dynamics of the cooling process of Ps within the nanochannels has been provided yet. In this work, we present a classical Monte Carlo model of Ps cooling produced in NCPs and validate it against experimental values present in the literature. Our model allows us to estimate crucial characteristics such as the cooling time in NCPs, the angular distribution of emitted Ps, and the fraction of Ps annihilating into three gamma quanta. The simulated energy spectra of emitted Ps closely match experimental results for NCPs held at room temperature. At cryogenic temperature the classical thermalization model does not accurately reproduce the measured spectra, which we attribute to a transition in the cooling process towards a regime where quantum effects play a significant role.
28 October 2023 in Scientific Reports
VBVassily Vadimovitch Burwitz
Vassily Vadimovitch Burwitz
Particle beams focused to micrometer-sized spots play a crucial role in forefront research using low-energy positrons. Their expedient and wide application, however, requires highly-resolved, fast beam diagnostics. We have developed two different methods to modify a commercial imaging sensor to make it sensitive to low-energy positrons. The first method consists in removing the micro-lens array and Bayer filter from the sensor surface and depositing a phosphor layer in their place. This procedure results in a detector capable of imaging positron beams with energies down to a few tens of eV, or an intensity as low as $${35}\,{\hbox {e}^+/\hbox {s/mm}^{2}}$$ when the beam energy exceeds 10 $${\hbox {keV}}$$ . The second approach omits the phosphor deposition; with the resulting device we succeeded in detecting single positrons with energies upwards of $${6}\,{\hbox {keV}}$$ and efficiency up to 93%. The achieved spatial resolution of 0.97 $$\upmu \hbox {m}$$ is unprecedented for real-time positron detectors.