26 June 2023 in Digital Diagnostics
BACKGROUND: Artificial intelligence (AI) is a system based on machine learning of neural networks. AI structure resembles nerve tissue, having the so called neurons, i.e. mathematical codes. A neural network has three levels, including the input layer (information enters the system), the hidden layer (multidimensional data is analyzed), and the output layer (the system generates conclusions). Current neural networks use a perceptron, i.e. a neuron consisting of a large number of interconnected input and hidden layers, which makes the system capable of self-learning and analysis of non-linear data and generalization and processing of incomplete information, including the method of projection onto latent structures. AIM: To develope a program based on multivariate data analysis to determine the chewing efficiency at the stages of prosthetics. METHODS: In 2016, the Department of Orthopedic Dentistry and Orthodontics developed and tested a program for determining chewing efficiency based on the analysis of digital occlusiograms obtained by scanning dental prints on a wax plate. The results were processed by mathematical methods of multivariate data analysis using the projection on latent structures (the partial least-squares [PLS-2] model), which allowed assessing the relationship between the value of chewing efficiency and the area and brightness characteristics of the areas corresponding to occlusal contacts. The program compared the measurement results with the reference occlusiograms in the database and gave a conclusion. The experiments yielded statistically significant results for the efficiency of the program compared to traditional chewing tests. Due to the relevance of implementing AI in orthopedic treatment, the decision was made to improve the training methods of the program to update the existing array of reference data. Starting in 2019, 24 occlusiograms were added to the previously received data with dental defects from 9 to 12 teeth. Using an expanded database, the program, when analyzing the occlusiogram of a new patient, allowed to consider changes in chewing efficiency obtained earlier with the Trezubov chewing test for various defects of the dentition and compare the reference and minimally achievable values of chewing efficiency. The program algorithm was verified by the researchers using the classical Trezubov chewing test. Chewing efficiency was measured as a percentage. RESULTS: The obtained combinations of the digital algorithm parameters for assessing chewing efficiency resulted in increased accuracy in the range of 4%6% compared to the traditional Rubinov and Ryakhovsky chewing tests. CONCLUSIONS: A digital algorithm for assessing chewing efficiency allows for quick and accurate assessment without the use of time-consuming analog tests.
2 July 2024 in Digital Diagnostics
BACKGROUND: Modern dentistry is not without advanced technologies, and intraoral scanning is becoming an increasingly important element of diagnosis and treatment. This technology is constantly evolving, offering new possibilities. The fundamental principles underlying the functionality of the intraoral scanner are light-measuring technology and photogrammetry. Light-emitting diodes integrated into the scanner body emit light onto the surface of the teeth, and sensors subsequently record the reflected signals, thereby creating an accurate three-dimensional model. The data is then processed by software that generates detailed digital models of the patient's jaws that are compatible with 3D CT data [1]. AIM: The study aimed to assess the potential of three-dimensional scanning for the planning and implementation of a single-stage dental implant protocol. MATERIALS AND METHODS: Patient M., aged 41, presented to the dental clinic with complaints of a fractured tooth on the upper jaw (1.2). A decision was made to perform a single-stage implantation with the extraction of tooth 1.2 and the placement of a temporary crown based on the results of the examination. Intraoral scanning of the jaws was performed for the fabrication of the crown, as the cutting edge of the tooth was destroyed by two-thirds and the tooth fragment was lost. In order to create a model of the crown, the horizontal inversion technique was used. Tooth 2.2 was extracted from the scan of the upper jaw and inverted horizontally, resulting in a copy of tooth 1.2 in the expanded state. This was done to reproduce the exact shape of the future crown. The design of the crown was modeled in the program in conjunction with the loaded model of the temporary abutment (implant suprastructure for the fixation of the artificial crown). This approach enabled the accurate contour of the crown eruption and correct positioning relative to the gingival cuff and the abutment shaft to be obtained. RESULTS: The implementation of the technique permitted the creation of an accurate and anatomically correct model of the crown of the replaced tooth without its introduction into occlusion, thereby reducing the risk of functional overload of the implant during the period of osseointegration (engraftment) [2]. The applied method enables the exclusion of the stage of crown correction at the moment of its fixation and the combination of 3D scans with data from computed tomography for the detailed planning of the surgery. Furthermore, the use of 3D scans permitted the visualization of the projected position of the future temporary crown, thereby enabling the precise positioning of the implant in an anatomically correct location. CONCLUSIONS: This case study illustrates the efficacy of planning and implementing single-stage implantation with the aid of intraoral jaw scanning, as it reduces treatment duration, eliminates the necessity for implant loading, and ensures the attainment of a predictable treatment outcome. These technologies are currently being actively implemented in Russian dentistry, with new treatment options continually emerging.