Murat Yolcu

Murat Yolcu

Auto-generated profile, based on publicly available information

Murat Yolcu

Giresun Üniversitesi

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2004 in Microchimica Acta
Verified
Journal Article
Closed access
PDF file
IIIbrahim Isildak
Ibrahim Isildak
MYMurat Yolcu
Murat Yolcu
OIOmer Isildak
Omer Isildak
NDNadir Demirel
Nadir Demirel
GTGiray Topal
Giray Topal
HHHalil Hosgoren
Halil Hosgoren

15 March 2012 in Biochemical Engineering Journal
Verified
Journal Article
Closed access
IIIbrahim Isildak
Ibrahim Isildak
OCOsman Cubuk
Osman Cubuk
MAMelda Altikatoglu
Melda Altikatoglu
MYMurat Yolcu
Murat Yolcu
VEVildan Erci
Vildan Erci
NTNihat Tinkilic
Nihat Tinkilic

9 June 2005 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
HKHeike Kahlert
Heike Kahlert
JPJens R. Pörksen
Jens R. Pörksen
IIIbrahim Isildak
Ibrahim Isildak
MAMüberra Andac
Müberra Andac
MYMurat Yolcu
Murat Yolcu
FSFritz Scholz
Fritz Scholz

8 March 2018 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
MYMurat Yolcu
Murat Yolcu
NDNurşen Dere
Nurşen Dere

22 July 2013 in Journal of Food Processing and Preservation
Verified
Journal Article
Closed access
PDF file
AGAytaç Güder
Aytaç Güder
MEMehmet Soner Engİn
Mehmet Soner Engİn
MYMurat Yolcu
Murat Yolcu
MGMahmut Gür
Mahmut Gür

15 March 2022 in Acta Chimica Slovenica
Verified
Journal Article
Open access
PDF file
NDNurşen Dere
Nurşen Dere
ZYZuhal Yolcu
Zuhal Yolcu
MYMurat Yolcu
Murat Yolcu
A novel solid-state polyvinylchloride (PVC) membrane potentiometric dopamine-selective microsensor was constructed based upon dopamine-imprinted polymer (DOP-IP) used as the ionophore in the membrane structure. The optimum membrane composition was determined as 4% (w/w) DOP-IP, 69% (w/w) bis(2-ethylhexyl) sebacate (DOS), 26% (w/w) PVC, and 1% (w/w) potassiumtetrakis(4-chlorophenyl) borate (KTpClPB). The detection limit of the microsensor was determined to be 3.71 × 10–7 mol L–1. The microsensor exhibited a super-Nernstian response for dopamine over the concentration range of 10–6−10–1 mol L–1, with a short response time (<15 s) and a slope of 60.3 ± 1.3 mV per decade (R2: 0.9998) over seven weeks. The microsensor was effectively performed in a pH range of 4.0−8.0 and a temperature range of 5−30 °C. The microsensor has been successfully demonstrated for the rapid, accurate, selective and reproducible determination of dopamine in pharmaceutical formulations with the recovery of 104.3–104.8%. The obtained results were in good harmony with the UV-Vis results at a confidence level of 95%.