Niral P. Shah

Niral P. Shah

Auto-generated profile, based on publicly available information

Niral P. Shah

Nuclear Engineering and Radiological Sciences Department, University of Michigan, Ann Arbor, MI, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2020 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
NSNiral P Shah
Niral P Shah
JVJacob VanderZanden
Jacob VanderZanden
DWDavid K. Wehe
David K. Wehe

18 February 2021 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
NSNiral P. Shah
Niral P. Shah
PMPeter Marleau
Peter Marleau
JFJeffrey A. Fessler
Jeffrey A. Fessler
DCDavid L. Chichester
David L. Chichester
DWDavid K. Wehe
David K. Wehe
To the first order, the localization precision and angular resolution of a cylindrical, time-encoded imaging (c-TEI) system is governed by the geometry of the system. Improving either measure requires increasing the mask radius or decreasing the detector diameter, both of which are undesirable. We propose an alternative option of repositioning the detector within the mask to increase the detector-to-mask distance in the direction of a source, thereby improving the localization precision and angular resolution in that direction. Since the detector-to-mask distance only increases for a small portion of the field of view (FOV), we propose implementing adaptive imaging where one leverages data collected during the measurement to optimize the system configuration. This article utilizes both simulations and experiments to set upper bounds on the potential gain from adaptive detector movements for one and two sources in the FOV. When only one source is present, adaptive detector movements can improve the localization precision and angular resolution by 20% for a source at 90 cm and by 32% for a far-field source. When two sources are present, adaptive detector movements can improve localization precision and angular resolution by up to 50% for sources that are ~10° apart (90 cm from the system). We experimentally verify these results through maximum likelihood estimation of the source position(s) and image reconstruction of point sources that are close together. As a demonstration of an adaptive imaging algorithm, we image a complex arrangement of special nuclear material at the Zero Power Physics Reactor facility at Idaho National Laboratory.