Benjamin Nti

Benjamin Nti

Auto-generated profile, based on publicly available information

Benjamin Nti

Department of Emergency Medicine Indiana University School of Medicine Indianapolis Indiana USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2022 in Journal of Ultrasound in Medicine
Verified
Journal Article
Open access
BNBenjamin Nti
Benjamin Nti
ALAmalia S. Lehmann
Amalia S. Lehmann
AHAida Haddad
Aida Haddad
SKSarah K. Kennedy
Sarah K. Kennedy
FRFrances M. Russell
Frances M. Russell
Objective: Respiratory symptoms are among the most common chief complaints of pediatric patients in the emergency department (ED). Point‐of‐care ultrasound (POCUS) outperforms conventional chest X‐ray and is user‐dependent, which can be challenging to novice ultrasound (US) users. We introduce a novel concept using artificial intelligence (AI)‐enhanced pleural sweep to generate complete panoramic views of the lungs, and then assess its accuracy among novice learners (NLs) to identify pneumonia.Methods: Previously healthy 0‐ to 17‐year‐old patients presenting to a pediatric ED with cardiopulmonary chief complaint were recruited. NLs received a 1‐hour training on traditional lung POCUS and the AI‐assisted software. Two POCUS‐trained experts interpreted the images, which served as the criterion standard. Both expert and learner groups were blinded to each other's interpretation, patient data, and outcomes. Kappa was used to determine agreement between POCUS expert interpretations.Results: Seven NLs, with limited to no prior POCUS experience, completed examinations on 32 patients. The average patient age was 5.53 years (±1.07). The median scan time of 7 minutes (minimum–maximum 3–43; interquartile 8). Three (8.8%) patients were diagnosed with pneumonia by criterion standard. Sensitivity, specificity, and accuracy for NLs AI‐augmented interpretation were 66.7% (confidence interval [CI] 9.4–99.1%), 96.5% (CI 82.2–99.9%), and 93.7% (CI 79.1–99.2%). The average image quality rating was 2.94 (±0.16) out of 5 across all lung fields. Interrater reliability between expert sonographers was high with a kappa coefficient of 0.8.Conclusion: This study shows that AI‐augmented lung US for diagnosing pneumonia has the potential to increase accuracy and efficiency.

21 October 2022 in The Ultrasound Journal
Verified
Journal Article
Open access
PDF file
BNBenjamin K. Nti
Benjamin K. Nti
WPWhitney Phillips
Whitney Phillips
Elisa J SarmientoElisa J Sarmiento
Elisa J Sarmiento
FRFrances Russell
Frances Russell
Background: Pediatric emergency department (ED) visits for superficial skin and soft tissue infections (SSTI) have steadily been increasing and point-of-care ultrasound (POCUS) continues to be an effective modality to improve management and shorter ED length of stays (LOS). Objective: We sought to determine the impact of a soft tissue POCUS curriculum on POCUS utilization, ED LOS, and cost-effectiveness. Methods: This was a retrospective pre- and post-interventional study of pediatric patients aged 0 to 17 years. Patients presenting to ED with international classification of disease 9 or 10 code for abscess or cellulitis were included. Data were collected a year before and after curriculum implementation with a 1-year washout training period. Training included continuing medical education, greater than 25 quality assured examinations, and a post-test. We compared diagnostic imaging type, ED LOS, and mean charges in patients with SSTI. Results: We analyzed data on 119 total patients, 38 pre- and 81 post-intervention. We found a significant increase in the total number of POCUS examinations performed pre- to post-curriculum intervention, 26 vs. 59 ( p = 0.0017). Mean total charges were significantly decreased from $3,762 (± 270) to $2,622 (± 158; p = 0.0009). There was a significant trend towards a decrease in average ED LOS 282 (standard error of mean [SEM] ± 19) vs 185 (± 13) minutes ( p = 0.0001). Conclusions: Implementation of a soft tissue POCUS curriculum in a pediatric ED was associated with increased POCUS use, decreased LOS, and lower cost. These findings highlight the importance of POCUS education and implementation in the management of pediatric SSTI.

22 June 2023 in AEM Education and Training
Verified
Journal Article
Closed access
PDF file
FRFrances M. Russell
Frances M. Russell
AHAudrey Herbert
Audrey Herbert
SKSarah Kennedy
Sarah Kennedy
BNBenjamin Nti
Benjamin Nti
MPMollie Powell
Mollie Powell
RFRobinson Ferre
Robinson Ferre

20 February 2021 in Pediatric Emergency Care
Verified
Journal Article
Closed access
BNBenjamin K. Md Nti
Benjamin K. Md Nti
SKSarah Kennedy
Sarah Kennedy
ESElisa Msph-Epap Sarmiento
Elisa Msph-Epap Sarmiento
EWElizabeth Weinstein
Elizabeth Weinstein
FRFrances Russell
Frances Russell
Objective: As point-of-care ultrasound (POCUS) continues to evolve, a national standardized curriculum for training and credentialing pediatric emergency medicine (PEM) physicians is still lacking. The goal of this study was to assess PEM faculty in performing and interpreting POCUS during implementation of a training curriculum. Methods: Sixteen full-time PEM faculty with either limited or no prior POCUS experience were trained to perform 4 ultrasound studies. Twelve of the 16 completed the training with a goal of credentialing within 12 months of implementation. For each faculty, we assessed competency by comparing precurriculum and postcurriculum test assessments and by evaluating quality of POCUS acquisition and accuracy of interpretation. We also monitored the amount of continuing medical education (CME) hours completed to ensure a minimum didactic component. Results: We found a significant improvement in POCUS competency comparing precurriculum to postcurriculum test assessments (55.4% vs 75.6%, P < 0.0002). One thousand two hundred seventy images were submitted over the course of the curriculum. Accuracy, sensitivity, and specificity were 98.23% (confidence interval [CI] = 97.18–98.97), 97.01% (CI = 92.53–99.81), and 98.43% (CI = 97.33–99.81), respectively. Faculty self-rating of image quality was significantly higher than expert reviewer rating of image quality (3.4 ± 0.86 vs 3.2 ± 0.56, P < 0.0001). We found no change in expert reviewer rating of image quality over time. Faculty completed a combined 232.5 CME hours (average, 17.4 ± 10.8), with the majority of hours coming from an institutional POCUS CME workshop. Conclusions: These results show that a structured curriculum can improve PEM faculty POCUS competency.

8 April 2024 in Pediatric Emergency Care
Verified
Journal Article
Closed access
BNBenjamin K. Md Nti
Benjamin K. Md Nti
NBNicole Md Benzoni
Nicole Md Benzoni
RSRebecca Do Starr
Rebecca Do Starr
MHMatthew Hays
Matthew Hays
DVDylan Vish
Dylan Vish
FRFrances Md Russell
Frances Md Russell
Background: Ultrasound has established utility within pediatric emergency medicine and has an added benefit of avoiding excessive radiation exposure. The serial focused assessment with sonography in trauma (sFAST) examination is a potential alternative to improve pediatric trauma evaluation. We sought to evaluate the accuracy of sFAST in pediatric patients with blunt abdominal trauma. Methods: We performed a multicenter, retrospective observational study of electronic medical records, trauma registry data, and image archiving records of previous sFAST examinations. Examinations from pediatric patients (18 years or younger) who presented to an emergency department with blunt abdominal trauma were eligible for inclusion as long as the period between the first and second FAST was at least 30 minutes but no more than 24 hours. Demographic data and patient and outcomes were collected. Results: Data collected from 3 institutions found a total of 38 sFAST performed between July 2017 and September 2021 on eligible patients. Of these, there were 6 (15.4%) FAST examinations that were positive after an initial negative or indeterminate interpretation. The overall sensitivity and specificity of sFAST were 66.7% (95% confidence interval 22.3–95.7%) and 93.8% (79.2–99.3%), respectively. Conclusions: This pilot study found that sFAST can enhance blunt trauma evaluation and improve sensitivity and diagnostic accuracy. More data are needed to determine how sFAST can be utilized in pediatric patients with blunt abdominal trauma.

27 March 2025 in Journal of Emergency Nursing
Verified
Journal Article
Closed access
BNBenjamin K. Nti
Benjamin K. Nti
PSPamela Soriano
Pamela Soriano
SMSean Mulligan
Sean Mulligan
EDEmily Dever
Emily Dever
TBTresanay Bentley
Tresanay Bentley
EWElizabeth Weinstein
Elizabeth Weinstein