Interfaces, Confinement, Matériaux et Nanostructures (ICMN), Université d'Orléans, CNRS, UMR 7374, 1b rue de la Férollerie, CS 40059, 45071 Orléans Cedex 2, France
Auto-generated profile, based on publicly available information
Fabienne Méducin
Interfaces, Confinement, Matériaux et Nanostructures (ICMN), Université d'Orléans, CNRS, UMR 7374, 1b rue de la Férollerie, CS 40059, 45071 Orléans Cedex 2, France
The temperature-dependence of the cation distribution in synthetic spinel (MgAl2O4) was investigated using in situ time-of-flight neutron powder diffraction at ISIS, the pulsed-neutron source at the Rutherford Appleton Laboratory. Neutron diffraction patterns of stoichiometric MgAl2O4 were collected on heating from room temperature to ∼1600 K at pressures of ∼2.6 GPa. The cation distribution was determined directly from site occupancies obtained by Rietveld refinement. The equilibrium non-convergent ordering was analyzed using the O’Neill-Navrotsky (1983) thermodynamic model, which fits the observed behavior well over the temperature range of the measurements. Fitting the data between 790 and 1600 K yields α = 31(6) kJ/mol and β = −20(13) kJ/mol in the expression for the free energy of ordering. The high-pressure temperature-dependent behavior, as compared to equivalent ambient-pressure behavior, demonstrates that disordering occurs to a much greater extent in MgAl2O4 at high pressure and that pressure favors disordering toward the inverse structure.
1 August 2005 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Neutron resonance spectroscopy is demonstrated as a viable and reliable method for the determination of sample temperatures in high-pressure, high-temperature neutron diffraction studies at neutron spallation sources. The technique operates by characterizing the thermally induced Doppler broadening of neutron absorption resonances of heavy nuclei present within the sample assembly observed in transmission. Accuracies of have been readily achieved with data acquisition times of approximately 40 min. It is shown that the temperatures determined by this technique are independent of the sample pressure provided that the sample temperature is kept above the Debye temperature of the material whose resonances are being examined. A short list of candidate resonances for temperature measurement by neutron resonance spectroscopy is presented and suggestions volunteered for the combinations of elements most suitable for temperature measurement based on the experience of the authors.
21 January 2004 in Environmental Science & Technology