Military members are required to carry heavy loads frequently during training and active duty combat. We investigated if operationally relevant axial loads affect lumbar disc kinematics in forty‐one male active duty Marines with no previous clinically diagnosed pathology. Marines were imaged standing upright with and without load. From T2‐weighted magnetic resonance images, intervertebral disc (IVD) health and kinematic changes between loading conditions and across lumbar levels were evaluated using two‐way repeated measures analysis of variance tests. IVD kinematics with loading were compared between individuals with and without signs of degeneration on imaging. Linear regression analyses were performed to determine associations between IVD position and kinematic changes with loading. Fifty‐eight percent (118/205) of IVDs showed evidence of degeneration and 3% (7/205) demonstrated a disc bulge. IVD degeneration was not related to posterior annular position (P > .205). Changes in sagittal intervertebral angle were not associated with changes in posterior annular position between baseline and loaded conditions at any lumbar level (r < 0.267; P = .091‐.746). Intervertebral angles were significantly larger in the lower regions of the spine (P < .001), indicating increased local lordosis when moving in the caudal direction Disc height at the L5/S1 level was significantly smaller (6.3 mm, mean difference = 1.20) than all other levels (P < .001) and baseline posterior disc heights tended to be larger at baseline (7.43 mm ± 1.46) than after loading (7.18 ± 1.57, P = .071). Individuals with a larger baseline posterior annular position demonstrated greater reduction with load at all levels (P < .002), with the largest reductions at L5/S1 level. Overall, while this population demonstrated some signs of disc degeneration, operationally relevant loading did not significantly affect disc kinematics.
Summary: Anterior pelvic fixation is increasingly cited as a potentially important component of stable fixation for unstable anterior posterior compression (APC) and lateral compression (LC) pelvic ring injuries. Although anterior fixation constructs are frequently supplemented with the addition of percutaneous posterior fixation, this is not always possible given the degree of injury and/or coexisting sacral dysmorphism. Therefore, efforts should be made to maximize the strength of anterior fixation for these injuries. Superior pubic symphyseal plating has long been the gold standard for APC injuries because of ease of access and ability for long screws. Anterior-based plates additionally have been proposed for use in dual plating but only allow for short-caliber anterior to posterior screws in the pubic rami and ultimately have not been widely adopted. This article proposes and describes a novel technique of an anteriorly based “W-plate” with multiplanar screw trajectories that can be advanced through longer bony corridors in the pelvis as compared with existing strategies. Using a contoured, 5-hole reconstruction plate, the W-plate allows for anterior column (retrograde superior rami) screws to stabilize the anterior plating construct. This article details the W-plate technique and an associated case series of its use at multiple institutions.
OBJECTIVES: To compare stiffness, displacement, and load to failure (LTF) patterns of a novel anterior pelvic plating technique, W-plating, to superior parasymphyseal plating (SPSP) in anterior posterior compression type III (APC III) pelvic ring injuries in a biomechanical model. METHODS: Twelve fourth generation composite pelves with induced APC III injuries stabilized with posterior screw fixation and either W-plating or SPSP were stressed via the Instron machine under single leg stance (SLS) axial load and external rotation (ER) load. Motion was analyzed at the pubic symphysis (PS) and sacroiliac joints (SIJ). PS and SIJ displacement, rotation, and stiffness were compared between the W-plate and SPSP groups under simulated stressed conditions. T-test was used to compare means and significance was set at p<0.05. Unadjusted p-values were reported alongside effect sizes (Cohen’s d) and 95% confidence intervals (CI) to provide additional context regarding the magnitude and potential biomechanical relevance of the observed differences RESULTS: The W-plate demonstrated less inferior PS displacement than the SPSP under SLS with a large observed effect size (0.5 ± 0.4 mm vs 1.2 ± 0.5 mm, respectively, Cohen’s d = 1.47). Average PS displacement also demonstrated a large effect size favoring the W-plate construct (Cohen’s d = 1.07), though statistical significance was not reached (0.3 ± 0.3 mm vs 0.7 ± 0.3 mm respectively, p = 0.07). There were no significant differences in stiffness in the SLS for the W-plate versus SPSP (98.9 ± 11.2 vs 105 ± 6.6 N/mm, respectively, p = 0.6) or in ER (4.4 ± 2.2 v 3.1 ± 1.6, respectively, p = 0.3). When loaded to failure, the W-plate and the SPSP both failed at the posterior fixation with no significant difference between groups (1411± 221 v 1545 ± 225 N, respectively p = 0.4). CONCLUSIONS: In a biomechanical analysis of induced APC-III pelvic ring injury, W-plating performed similarly to SPSP in stiffness, displacement, and LTF. W-plating for anterior pelvic ring fixation was found to be biomechanically similar to SPSP with potentially increased resistance to anterior ring displacement. LEVEL OF EVIDENCE: V