Qun He

Qun He

Auto-generated profile, based on publicly available information

Qun He

Lanzhou University

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2007 in Microchimica Acta
Verified
Journal Article
Closed access
PDF file
QHQun He
Qun He
XCXijun Chang
Xijun Chang
XHXinping Huang
Xinping Huang
ZHZheng Hu
Zheng Hu

22 December 2009 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
JMJie Mao
Jie Mao
QHQun He
Qun He
WLWeisheng Liu
Weisheng Liu

10 March 2008 in International Journal of Environmental Analytical Chemistry
Verified
Journal Article
Closed access
QHQun He
Qun He
XCXijun Chang
Xijun Chang
HZHong Zheng
Hong Zheng
NJNa Jiang
Na Jiang
XWXiaoyan Wang
Xiaoyan Wang
A sensitive and selective method has been developed to determine Cr(III) and total Cr in natural water samples by ICP-AES with a Cr(III)-imprinted aminopropyl-functionalised silica gel adsorbent. The Cr(III)-imprinted and non-imprinted adsorbent were prepared by an easy one-step reaction with a surface imprinting technique. Their maximum static adsorption capacities for Cr(III) were 11.12 mg g−1 and 3.81 mg g−1, respectively. The relative selectivity factors (α r) for Cr(III)/Co(II), Cr(III)/Au(III), Cr(III)/Ni(II), Cr(III)/Cu(II), Cr(III)/Zn(II), and Cr(III)/Cr(VI), were 377, 21.4, 15.4, 27.7, 26.4, and 31.9, respectively. Under the optimal conditions, Cr(III) can be absorbed quantitatively, but Cr(VI) was not retained. Total chromium was obtained after reducing Cr(VI) to Cr(III) with hydroxyammonium chloride. The detection limit (3σ) for Cr(III) was 0.11 ng mL−1. The relative standard deviation was 1.2%. The proposed method has been validated by analysing two certified reference materials and successfully applied to the determination and speciation of chromium in natural water samples with satisfactory results.

31 August 2011 in Materials Letters
Verified
Journal Article
Closed access
SZShengrui Zhang
Shengrui Zhang
QHQun He
Qun He
RLRuijun Li
Ruijun Li
QWQin Wang
Qin Wang
ZHZheng Hu
Zheng Hu
XCXijun Chang
Xijun Chang

1 August 2006 in Solvent Extraction and Ion Exchange
Verified
Journal Article
Closed access
NLNing Lian
Ning Lian
XCXijun Chang
Xijun Chang
HZHong Zheng
Hong Zheng
QHQun He
Qun He
NJNa Jiang
Na Jiang
HSHongzong Si
Hongzong Si
A novel poly(acryl‐benzoylamidrazone‐acryl‐benzoylhydrazine) chelating fiber was synthesized simply and rapidly from polyacrylonitrile fiber and benzoyl hydrazine. The chelating fiber was used for preconcentrating and separating traces of Cr(III), Bi(III), Sn(IV), V(V), Ti(IV), and Zr(IV) from solution samples. These ions can be quantitatively enriched with the chelating fiber column at pH 4.0 and a flow rate of 1.0–10.0 mL min−1 and desorbed with 15 mL of 4.0 mol L−1 HCl solution from the fiber column with the recoveries over 95%. When the fiber was reused ten times, the recoveries of Cr(III), Bi(III), Sn(IV), V(V), Ti(IV), and Zr(IV) enriched by the fiber were still over 95%. Twenty to thousands‐fold excesses of Ca(II), Mg(II), Cu(II), Ba(II), Zn(II), Mn(II), Al(III), and Fe(III) cause little interference with the concentration of the target metal ions, as demonstrated by using a inductively coupled plasma atomic emission spectrometry (ICP‐AES). The structure of the chelating fiber was deduced by infrared spectrometry, and the enrichment mechanism of metal ions was discussed.