Noah Heldt

Noah Heldt

Auto-generated profile, based on publicly available information

Noah Heldt

German Center of Lung Research (DZL)

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2025 in Biomedical Optics Express
Verified
Journal Article
Open access
NHNoah Heldt
Noah Heldt
TMTual Monfort
Tual Monfort
RMRion Morishita
Rion Morishita
RSRobert Schönherr
Robert Schönherr
OTOlivier Thouvenin
Olivier Thouvenin
YYYoshiaki Yasuno
Yoshiaki Yasuno
Dynamic optical coherence tomography (DOCT) enhances conventional OCT by providing specific information related to flow dynamics, cell motility, and organelle metabolic activity. These biological phenomena can be detected with varying sensitivity depending on the OCT architecture parameters, including wavelength, numerical aperture, and implementation method (time domain or Fourier domain). Despite its potential, the field lacks standardization as various research groups have independently developed algorithms for specific applications. In this paper, we compare four widely used DOCT algorithms, each employing a distinct analytical approach: power spectral density moment analysis, frequency band visualization, logarithmic intensity variation evaluation, and motility-based analysis. These algorithms were originally optimized for different OCT technologies (full-field OCT, microscopic OCT, swept-source OCT, and spectral domain OCT), which vary in temporal and spatial resolution as well as susceptibility to motion artifacts. To conduct a fair evaluation, we perform comprehensive cross-wise comparisons using datasets acquired from each of these setups. Our findings reveal that each method exhibits unique advantages in specific imaging environments, thereby providing valuable guidance for algorithm selection based on particular application requirements.

29 September 2025 in Biomedical Optics Express
Verified
Journal Article
Closed access
NHNoah Heldt
Noah Heldt
CHCornelia Holzhausen
Cornelia Holzhausen
MAMartin Ahrens
Martin Ahrens
MPMario Pieper
Mario Pieper
PKPeter König
Peter König
GHGereon Hüttmann
Gereon Hüttmann
Dynamic optical coherence tomography (dOCT) uses signal fluctuations to contrast different cells and tissues. In this paper, we demonstrate that shortening the time base over which the signal fluctuations are evaluated reduces noise induced by motion while still maintaining a decent image quality. Automatic clustering using the neural-gas algorithm is introduced to optimize the border between the color channels. The performance of the automatic border optimization is demonstrated with 15 different tissue samples by quantitative assessment of motion-induced noise and image quality using the mean squared error (MSE) between images and the image quality parameters peak signal to noise ratio (PSNR) and structural similarity (SSIM).

1 July 2026 in Biomedical Instrumentation
Verified
Journal Article
Open access
NHNoah Heldt
Noah Heldt
RSRobert Schönherr
Robert Schönherr
PKPeter König
Peter König
GHGereon Hüttmann
Gereon Hüttmann