21 June 2013 in Journal of Chromatographic Science
A simple high-performance liquid chromatography method has been developed for the determination of naproxen in human plasma. The method was validated on an Ace C18 column using ultraviolet detection. The mobile phase consisted of 20 mM phosphate buffer (pH 7) containing 0.1% trifluoroacetic acid–acetonitrile (65:35, v/v). The calibration curve was linear between the concentration ranges of 0.10 and 5.0 µg/mL. Intra-day and inter-day precision values for naproxen in plasma were less than 4.84, and accuracy (relative error) was better than 3.67%. The extraction recovery values of naproxen from human plasma were between 91.0 and 98.9%. The limits of detection and quantification of naproxen were 0.03 and 0.10 µg/mL, respectively. Also, this assay was applied to determine the pharmacokinetic parameters of naproxen in six healthy Turkish volunteers who had been given 220 mg of naproxen.
15 April 2010 in Hemodialysis International
1 January 2022 in Anais da Academia Brasileira de Ciências
This study aimed to determine neopterin levels in the urine of industrial workers by the high-performance liquid chromatography method. Intra- and inter-day precision values for neopterin in urine were less than 3.14, and accuracy (relative error) was better than 3.00%. The limits of detection and quantification of neopterin were 0.3 and 1.0 ng/mL, respectively. Also, the developed method was applied to real samples to determine the neopterin levels in the urines of industrial workers, who have been exposed to various chemicals such as formaldehyde, heavy metals and thinners. Urine neopterin levels of industrial workers including auto painters, bodywork and furniture workers were statistically compared with healthy volunteers. The highest and lowest values of urinary neopterin for industrial workers were obtained 908.96 and 119.86 μmol/mol, respectively. Our investigation demonstrates that there is a meaningful difference in urinary neopterin levels between the workers and the control groups (P<0.05). Workers in the auto paint, body and furniture business may have been exposed to a toxic environmental exposure in their occupation. As a result, an increase in the concentration of neopterin in the urine may be important in the diagnosis and treatment of various diseases.
13 November 2026 in Pharmata
Objective: This study aimed to develop and validate simple, sensitive, and cost-effective UV-Visible and first-derivative spectrophotometric methods for the quantitative determination of chlorpromazine in pharmaceutical dosage forms.Methods: The UV-Visible spectrophotometric method was performed at 254 nm, whereas the first-derivative spectrophotometric method was evaluated at wavelengths of 247 nm and 261 nm. Both methods were comprehensively validated according to ICH Q2(R1) guidelines with respect to linearity, accuracy, precision, limit of detection and limit of quantification.Results: Linearity was achieved over the concentration range of 1-25 μg/mL for all proposed procedures. The developed methods demonstrated satisfactory accuracy, with relative error values ranging from -1.87% to 6.64%, and acceptable precision, with relative standard deviation values ranging from 0.04% to 8.64% across intra-day and inter-day evaluations. The limits of detection (LOD) and quantification (LOQ) were calculated as 0.29 μg/mL and 0.89 μg/mL, respectively. The first-derivative spectrophotometric approach provided improved spectral resolution and reduced the influence of potential spectral overlap from formulation components. The validated methods were successfully applied to the determination of chlorpromazine in tablet and ampoule pharmaceutical preparations.Conclusion: The obtained results indicate that the proposed spectrophotometric methods provide rapid, reliable and economical alternatives for routine pharmaceutical quality
28 January 2023 in Ankara Universitesi Eczacilik Fakultesi Dergisi
Objective: Polychlorinated biphenyls (PCBs) were very widely used in industrial products in past. These chemicals were banned in the 1970s due to their toxic effects. PCBs can still affect human health, as they are persistent in the environment. Aroclor 1254 (A1254) is a commercial PCB congener which was used in electrical transformers, fluorescent lighting fixtures and old appliances such as televisions or refrigerators. In this study, we aimed to evaluate the toxic effects of A1254 on heart and thyroid in male Sprague-Dawley rats. In addition, the modifying role of selenium status was also evaluated. Material and Method: 8-week-old male Sprague-Dawley (SD) rats were used in the experiment. The animals were separated randomly into 6 groups (n=6) as control; selenium supplemented (SeS); selenium deficient (SeD); A1254 exposed (A); selenium supplemented A1254 exposed (ASeS) and selenium deficient A1254 exposed (ASeD). A1254 was applied by gavage during the last 15 days of feeding period. Heart and thyroid weights and relative weights, plasma thyroid hormone levels, as well as thyroid and heart tissue oxidative/antioxidative parameters were evaluated. Result and Discussion: Results showed that A1254 exposure and selenium deficiency caused oxidative stress on both heart and thyroid. Plasma fT3 and fT4 levels markedly changed in ASeD group. In conclusion, it can be stated that A1254 exposure can cause lead to oxidative/antioxidative imbalance in both thyroid and heart and can disrupt functioning of thyroid hormones. Selenium seems to have a modifying role in A1254 toxicity in both organs, the importance of which should be evaluated with further mechanistic experiments.