1 March 2016 in Ain Shams Engineering Journal
As a result of privatization of the electrical industry the power transmission lines have to transfer power at their maximum transmission limits because of the competitive scenario of the electrical market. Hence, secured operation of power system has become one of the most important issues of modern era. In this paper, a probability of severity based placement strategy for Interline Power Flow Controller (IPFC) has been proposed based on Composite Severity Index (CSI). The composite severity index provides an exact measure of stress in the line in terms of mega watt overloading and voltage instability. IPFC is placed on the line which has the highest probability of severity during the occurrence of different outages. The IPFC has been tuned for a multi-objective function using Differential Evolution (DE) and the results have been compared with genetic Algorithm (GA). To verify the proposed method, it has been tested and implemented on IEEE 14 and 57 bus systems
1 January 2016 in IET Generation, Transmission & Distribution
As a consequence of privatisation and deregulation of the electric power market, there is a marked increase of scheduled power that flows in the transmission line and also the spontaneous power exchanges leading to complex power transmission congestion problems. The proper placement of interline power flow controller (IPFC) can improve the transmission line congestion problem to a great extent. This study proposes a method for optimal placement of IPFC based on disparity line utilisation factor (DLUF) and firefly algorithm (FA)‐based optimal tuning for a multi‐objective function to control the congestion in transmission lines. DLUF determines the difference between the percentages mega voltage ampere (MVA) utilisation of each line connected to the same bus. The IPFC is placed in the lines with maximum DLUF. This method has been implemented on an IEEE 30‐bus system and the results have been presented and analysed. Optimal tuning of IPFC at the proposed location is carried out using FA for a multi‐objective function consisting of active power loss, total voltage deviations, security margin and capacity of the installed IPFC. The tuning of IPFC is also carried out using genetic algorithm. The results obtained have been compared with that of FA for different loading conditions.
1 May 2017 in Journal of Electrical Systems and Information Technology
VGVenkata Nagesh Kumar G.
In a deregulated electricity market it may at times become difficult to dispatch all the required power that is scheduled to flow due to congestion in transmission lines. An Interline Power Flow Controller (IPFC) can be used to reduce the system loss and power flow in the heavily loaded line, improve stability and loadability of the system. This paper proposes a Disparity Line Utilization Factor for the optimal placement and Gravitational Search algorithm based optimal tuning of IPFC to control the congestion in transmission lines. DLUF ranks the transmission lines in terms of relative line congestion. The IPFC is accordingly placed in the most congested and the least congested line connected to the same bus. Optimal sizing of IPFC is carried using Gravitational Search algorithm. A multi-objective function has been chosen for tuning the parameters of the IPFC. The proposed method is implemented on an IEEE-30 bus test system. Graphical representations have been included in the paper showing reduction in LUF of the transmission lines after the placement of an IPFC. A reduction in active power and reactive power loss of the system by about 6% is observed after an optimally tuned IPFC has been included in the power system. The effectiveness of the proposed tuning method has also been shown in the paper through the reduction in the values of the objective functions
1 July 2016 in IET Generation, Transmission & Distribution
Provision of secured and uninterrupted supply of power is an essential pre‐requisite for the electrical industry. Hence, FACTS devices need to be employed efficiently to ensure the security of the power system. This study proposes, a repetition of severity‐based strategy of placement of interline power flow controller (IPFC) using composite severity index (CSI) for contingency management. The formulated CSI is a combination of real power performance index) and line stability index
L
mn
. Thus, the CSI is expected to provide an exact measure of stress on the lines in terms of MW overloading and voltage instability. The IPFC is further tuned for a multi‐objective function using firefly algorithm. To verify the proposed methodology, it has been tested and implemented on IEEE 30 and Indian utility 62 bus system. The system has been further tested under highly stressful condition by increasing the load on the maximum loaded bus up to the critical value. The results have been presented and analysed to determine the effectiveness of IPFC for contingency management.
1 September 2015 in CSEE Journal of Power and Energy Systems
The restructuring of the electric power market has led to complex power transmission congestion problems. Additionally, scheduled power flows in the transmission line, as well as spontaneous power exchanges have also risen sharply in recent years. Th...
21 May 2016 in Electric Power Components and Systems
In the traditional approach of steady-state contingency screening, each line is removed sequentially and its effect on the system is studied, while only some contingencies may cause certain lines to become severe. This article presents an approach for fast contingency ranking in steady-state, based on the selection of a limited number of important buses. A composite severity index based placement of interline power flow controller and tuning using differential evolution for IEEE 14- and 30-bus systems has also been proposed. The composite severity index is a combination of line utilization factor and fast voltage stability index. All the lines connected to the important buses only are sequentially considered for line outage and the most severe line corresponding to each outage is ranked on the basis of composite severity index. An interline power flow controller is optimally placed and tuned to improve the system post-contingency condition. Differential evolution has been used to tune the device for a multi-objective function. The load on the system is increased to test the performance of the interline power flow controller under highly stressed conditions.