Radiation therapy to the prostate involves increasingly sophisticated delivery techniques and changing fractionation schedules. With a low estimated α/β ratio, a larger dose per fraction would be beneficial, with moderate fractionation schedules rapidly becoming a standard of care. The integration of a magnetic resonance imaging (MRI) scanner and linear accelerator allows for accurate soft tissue tracking with the capacity to replan for the anatomy of the day. Extreme hypofractionation schedules become a possibility using the potentially automated steps of autosegmentation, MRI-only workflow, and real-time adaptive planning. The present report reviews the steps involved in hypofractionated adaptive MRI-guided prostate radiation therapy and addresses the challenges for implementation.
Daily magnetic resonance (MR)-guided radiation has the potential to improve stereotactic body radiation therapy (SBRT) for tumors of the liver. Magnetic resonance imaging (MRI) introduces unique variables that are untested clinically: electron return effect, MRI geometric distortion, MRI to radiation therapy isocenter uncertainty, multileaf collimator position error, and uncertainties with voxel size and tracking. All could lead to increased toxicity and/or local recurrences with SBRT. In this multi-institutional study, we hypothesized that direct visualization provided by MR guidance could allow the use of small treatment volumes to spare normal tissues while maintaining clinical outcomes despite the aforementioned uncertainties in MR-guided treatment. Patients with primary liver tumors or metastatic lesions treated with MR-guided liver SBRT were reviewed at 3 institutions. Toxicity was assessed using National Cancer Institute Common Terminology Criteria for Adverse Events Version 4. Freedom from local progression (FFLP) and overall survival were analyzed with the Kaplan-Meier method and χ2 test. The study population consisted of 26 patients: 6 hepatocellular carcinomas, 2 cholangiocarcinomas, and 18 metastatic liver lesions (44% colorectal metastasis). The median follow-up was 21.2 months. The median dose delivered was 50 Gy at 10 Gy/fraction. No grade 4 or greater gastrointestinal toxicities were observed after treatment. The 1-year and 2-year overall survival in this cohort is 69% and 60%, respectively. At the median follow-up, FFLP for this cohort was 80.4%. FFLP for patients with hepatocellular carcinomas, colorectal metastasis, and all other lesions were 100%, 75%, and 83%, respectively. This study describes the first clinical outcomes of MR-guided liver SBRT. Treatment was well tolerated by patients with excellent local control. This study lays the foundation for future dose escalation and adaptive treatment for liver-based primary malignancies and/or metastatic disease.
To quantify the indication for adaptive, gated breath-hold (BH) MR-guided radiotherapy (MRgRTBH) versus BH or free-breathing (FB) CT-based image-guided radiotherapy (CT-IGRT) for the ablative treatment of adrenal malignancies. Twenty adrenal patients underwent adaptive IMRT MRgRTBH to a median dose of 50 Gy/5 fractions. Each patient was replanned for VMAT CT-IGRTBH and CT-IGRTFB on a c-arm linac. Only CT-IGRTFB used an ITV, summed from GTVs of all phases of the 4DCT respiratory evaluation. All used the same 5 mm GTV/ITV to PTV expansion. Metrics evaluated included: target volume and coverage, conformality, mean ipsilateral kidney and 0.5 cc gastrointestinal organ-at-risk (OAR) doses (D0.5cc). Adaptive dose for MRgRTBH and predicted dose (i.e., initial plan re-calculated on anatomy of the day) was performed for CT-IGRTBH and MRgRTBH to assess frequency of OAR violations and coverage reductions for each fraction. The more common VMAT CT-IGRTFB, with its significantly larger target volumes, proved inferior to MRgRTBH in mean PTV and ITV/GTV coverage, as well as small bowel D0.5cc. Conversely, VMAT CT-IGRTBH delivered a dosimetrically superior initial plan in terms of statistically significant (p ≤ 0.02) improvements in target coverage, conformality and D0.5cc to the large bowel, duodenum and mean ipsilateral kidney compared to IMRT MRgRTBH. However, non-adaptive CT-IGRTBH had a 71.8% frequency of predicted indications for adaptation and was 2.8 times more likely to experience a coverage reduction in PTV D95% than predicted for MRgRTBH. Breath-hold VMAT radiotherapy provides superior target coverage and conformality over MRgRTBH, but the ability of MRgRTBH to safely provide ablative doses to adrenal lesions near mobile luminal OAR through adaptation and direct, real-time motion tracking is unmatched.
This work describes a novel application of MR-guided online adaptive radiotherapy (MRgoART) in the management of patients whom urgent palliative care is indicated using statum-adaptive radiotherapy (STAT-ART). The implementation of STAT-ART, as performed at our institution, is presented including a discussion of the advantages and limitations compared to the standard of care for palliative radiotherapy on conventional c-arm linacs. MR-based treatment planning techniques of STAT-ART for density overrides and deformable image registration (DIR) of diagnostic CT to the treatment MR are also addressed.