8 October 2021 in IEEE Journal of Solid-State Circuits
Current retinal prostheses (RPs) have not achieved useful vision restoration, as their resolution is limited by power dissipation and complexity of interconnect. This article presents an inductively powered wireless system on a chip (SoC) for an electrically controlled, optically addressed retinal prosthetic system. The SoC interfaces to a co-fabricated nanoengineered photosensitive electrode array using only two wires. To reduce the thermal dissipation near sensitive retinal tissue, the proposed design pushes voltage regulation and charge-balanced stimulation control off the implant via a duty-cycled wireless charge metering technique. A calibration technique compensating for power fluctuation caused by eye movement is also presented. Implemented in 180-nm CMOS and delivering up to $3~\mu \text{C}$ of charge at 20-nC resolution, the SoC achieves 73% RF-to-stimulation power efficiency.
26 February 2024 in IEEE Transactions on Biomedical Circuits and Systems
Advances in brain-machine interfaces and wearable biomedical sensors for healthcare and human-computer interactions call for precision electrophysiology to resolve a variety of biopotential signals across the body that cover a wide range of frequencies, from the mHz-range electrogastrogram (EGG) to the kHz-range electroneurogram (ENG). Existing integrated wearable solutions for minimally invasive biopotential recordings are limited in detection range and accuracy due to trade-offs in bandwidth, noise, input impedance, and power consumption. This article presents a 16-channel wide-band ultra-low-noise neural recording system-on-chip (SoC) fabricated in 65nm CMOS for chronic use in mobile healthcare settings that spans a bandwidth of 0.001 Hz to 1 kHz through a featured sample-level duty-cycling (SLDC) mode. Each recording channel is implemented by a delta-sigma analog-to-digital converter (ADC) achieving 1.0 μ V rms input-referred noise over 1Hz–1kHz bandwidth with a Noise Efficiency Factor (NEF) of 2.93 in continuous operation mode. In SLDC mode, the power supply is duty-cycled while maintaining consistently low input-referred noise levels at ultra-low frequencies (1.1 μ V rms over 0.001Hz–1Hz) and 435 MΩ input impedance. The functionalities of the proposed SoC are validated with two human electrophysiology applications: recording low-amplitude electroencephalogram (EEG) through electrodes fixated on the forehead to monitor brain waves, and ultra-slow-wave electrogastrogram (EGG) through electrodes fixated on the abdomen to monitor digestion.