Glaucoma involves both structural and functional impairments, necessitating an integrated approach to evaluate disease progression. Structural atrophy of the retinal nerves and functional visual field (VF) loss are key indicators of glaucomatous damage. Early structural changes in the ganglion cell layer (GCL) and retinal nerve fiber layer (RNFL) can be detected using highresolution optical coherence tomography (OCT) [1], while VF testing reveals early functional defects [2]. However, despite advancements in OCT technology, limitations in its interpretation remain a significant challenge. OCT uses color-coded maps to categorize RNFL thickness values: white and green indicating normal ranges, yellow for borderline, and red for below-normal levels. While these maps provide quick visual guidance, overreliance on them can lead to missed early glaucomatous changes, a phenomenon termed "green disease" [3-5]. Variations in normative databases, device calibration, and patient demographics contribute to this issue, as subtle structural changes may not trigger abnormal color coding. Clinicians should look beyond the color-coded 4-quadrant RNFL maps to avoid underdiagnosis.
Purpose: Accurate intraocular pressure (IOP) measurement is essential for glaucoma management. However, corneal irregularities may affect the tonometer's accuracy. This study aims to assess the agreement between Icare Home (ICH) rebound tonometry and Goldmann Applanation Tonometry (GAT) in patients with keratoconus and to investigate the impact of corneal parameters and keratoconus severity on IOP measurements. Methods: In this cross-sectional study, 48 eyes of 25 patients with keratoconus underwent same-day IOP measurements with GAT and ICH. Agreement between methods was analyzed using Bland–Altman plots. Spearman rank correlation was used to assess associations between IOP and corneal parameters. Results: The mean IOP was 11.98 ± 2.52 mm Hg for GAT and 10.45 ± 2.85 mm Hg for ICH. The mean absolute difference between devices was 2.65 ± 2.16 mm Hg ( P <0.001), and the mean arithmetic difference was 1.53 ± 3.06 mm Hg ( P = 0.0018), with 54.17% of cases falling within the ±2 mm Hg. Bland–Altman analysis showed 95% limits of agreement from −4.47 to 7.53 mm Hg. ICH IOP was positively correlated with MCT (ρ = 0.389, P = 0.0063) and negatively correlated with astigmatism (ρ = −0.512, P = 0.0002), Kmax (ρ = −0.411, P = 0.0037), K1 (ρ = −0.515, P = 0.0002), and K2 (ρ = −0.43, P = 0.0023). GAT IOP showed no significant correlation with these parameters. Conclusions: ICH underestimated IOP compared with GAT, with substantial variability between the methods. Corneal parameters were significantly associated with ICH readings. These findings highlight the limited reliability of ICH in advanced keratoconus, where clinically significant measurement differences may affect patient management.