Observation and characterization of any changes in anatomical structures of ocular components remain as a conventional technique for diagnosis, staging, therapeutic treatments, and post-treatment monitoring of any ophthalmic disorders. The existing technologies fail to provide imaging of all of the various components of the eye simultaneously at one scanning time, i.e., one can recover vital patho-physiological information (structure and bio-molecular content) of the different ocular tissue sections only one after another. This article addresses the longstanding technological challenge by use of an emerging imaging modality [photoacoustic imaging (PAI)] in which we integrated a synthetic aperture reconstruction technique (SAFT). Experimental results—with experiments being conducted in excised tissues (goat eye)—demonstrated that we can simultaneously image the entire structure of the eye (∼2.5 cm) depicting clearly the distinctive ocular structures (cornea, aqueous humor, iris, pupil, eye lens, vitreous humor, and retina). This study uniquely opens an avenue for promising ophthalmic (clinical) applications of high clinical impact.
For the first time, we present photoacoustic (PA) imaging using a single-element (single-cell) piezoelectric micromachined ultrasound transducer (PMUT) with a low resonant frequency of approximately 1 MHz and a compact effective aperture as tiny as 0.06 mm $^{2}$ . Adding to this innovation, we introduce pioneering image enhancement techniques applied directly to images obtained from this standalone single-cell PMUT, aiming to elevate and refine PA image quality. Our approach employs a trio of advanced methods: 1) frame averaging to ensure clarity by reducing image clutter; 2) cutting-edge mathematical algorithms to fine-tune image quality metrics; and 3) precise hardware positioning for accurate image capture. These techniques underwent rigorous validation using both agar phantom and ex-vivo tissue samples. As benchmarks for our progress, we utilized quantifiers including full width at half maximum (FWHM), signal-to-noise ratio (SNR), and contrast ratio (CR). Our results were striking: a 34% improvement in FWHM, a 23% boost in SNR, and a 25% enhancement in CR. These numbers clearly demonstrate the efficacy of our methods in optimizing PA images through a low-frequency PMUT-based detector. In conclusion, our research indicates that these enhancement methods could be instrumental in shaping a cost-effective and efficient future for PMUT-based photoacoustic imaging (PAI) systems.
27 December 2023 in Physical and Engineering Sciences in Medicine
Images, not necessarily to be photoacoustic (PA), are conventionally reconstructed from a collection of boundary-measured data that are also comprised of a significantly large percentage of background noisy signals delivering no pertaining information, and thus, the obtainable imaging performance is remarkably degraded. This article presents a novel and unique technique to undertake image reconstruction, taking into account only the selective signals of importance while filtering out the unwanted noisy signals selectively, that immensely enhances the achievable image quality. Quantitative validation studies − both simulations and experiments in diversified samples (agars, leaf-veins, and excised tissues (chicken-breasts)) using our home-built photoacoustic imaging (PAI) modalities both tomography (PAT) and microscopy (PAM) − demonstrate a significant enhancement in the imaging performance that are quantified in terms of various statistical parameters of great interest in practical clinical applications, say, signal-to-noise-ratio (SNR) (~ 25-94%), contrast-ratio (CR) (~ 164-189%), axial-resolution (~ 40-49%), and lateral-resolution (~ 27-62%).
Purpose: To develop and validate a phantom for diagnostic ultrasound (US) scanners by embedding targets in gel wax to determine the image uniformity, lateral and axial resolution, and diameter of a stainless-steel disc. Materials and Methods: Acoustic property (AP), which includes the velocity of US (cus), acoustic impedance (Z), and attenuation coefficient in gel wax were determined. The cus, and attenuation coefficient were estimated using the pulse-echo technique. Z was obtained from the product of sample density (\r{ho}) and cus. Two rectangular frames using polytetrafluoroethylene (PTFE) sheets with holes separated by 5, 10, and 20 mm distances were constructed. Nylon filaments and SS-disc (diameter = 16.8 mm) were threaded through the frames and suitably placed in melted gel wax to obtain orthogonal targets. The targets were measured using computerized tomography (CT) and a 2-9 MHz US probe. Results: The AP of gel wax were cus=1418 m/s, \r{ho}= 0.87 g/cm3, Z=1.23 MRayls, attenuation coefficient= 0.88 dB/cm/MHz. The results of US imaging of the targets were compared with their physical sizes and served as baselines for the scanner and probe. The maximum error in distance measurement in the phantom US images was 7.1%, and the phantom volume decreased by 1.8% over 62 weeks. Conclusion: Gel wax can be useful in developing affordable, highly stable, and customizable diagnostic US phantoms that can be implemented widely.