Deployment of large numbers of low capital cost sensors to increase the spatial density of air quality measurements enables applications that build on mapping air at neighborhood scales. Effective deployment requires not only low capital costs for observations but also a simultaneous reduction in labor costs. The Berkeley Environmental Air Quality and CO2 Network (BEACO2N) is a sensor network measuring O3, CO, NO, and NO2, particulate matter (PM2.5), and CO2 at dozens of locations in cities where it is deployed. Here, we describe a low labor cost in situ field calibration for the BEACO2N O3, CO, NO, and NO2 sensors. This method identifies and leverages uniform periods in concentrations across the network for calibration. The calibration achieves high accuracy and low biases with respect to temperature, humidity, and concentration, with coefficients of determination and root mean square errors of 0.88 and 3.70 ppb for O3, 0.66 and 3.16 ppb for NO2, and 0.79 and 1.58 ppb for NO. Performance of the CO sensor is 0.90 and 33.3 ppb at a site colocated with reference measurements. The method is a crucial step toward lowering operational costs of delivering accurate measurements in dense networks employing large numbers of inexpensive air quality sensors.
Over the past decade, technological advancements and the growing demand for higher spatial resolution in air quality measurements have driven the widespread deployment of low-cost electrochemical gas sensors. These sensors are inexpensive, compact, easy to deploy, and have potential to detect variability in ambient air. While short-term sensor performance and calibration assessments have been well-documented, research on sensor reliability in long-term deployments remains limited. The Berkeley Environmental Air Quality and CO2 Network (BEACO2N) is a dense, long-term sensor network measuring O3, NO, NO2, and CO using electrochemical gas sensors, in addition to CO2 and PM2.5 with other sensors. Here, we evaluate the performance of the Alphasense NO2-B43F, Ox-B431, NO-B4, and CO-B4 sensors over the course of 3 years in the San Francisco Bay Area. We find consistent performance in the calibrated data over the 3 years. These findings highlight the reliability of long-term sensor use with appropriate calibration techniques and suggest the sensors remain suitable for extended deployments without requiring replacement.
Home heating preferences vary dramatically with regional climate. The temperature at which residents turn on natural gas home heating systems (critical temperature) varies by as much as 25°C from the northern to southern United States (U.S.). Here we derive temperature dependent CO2 emissions in three U.S. cities using a dense ground‐based CO2 observation network. A Bayesian inverse modeling methodology is used to update a 1‐km emission inventory in each of the three cities. This method is able to correctly identify the critical temperature of home heating even when this information is withheld from the prior inventory, as verified by natural gas distribution data. Variance in regional heating practices has not been previously demonstrated with ground‐based networks of CO2 observations. This result provides evidence that a Bayesian inverse modeling framework is sensitive to emissions of the home heating sector.
Point sources are often major contributors of greenhouse gas and air pollutant emissions in urban areas. Dense air monitoring networks provide a unique avenue for studying point source emissions over long time periods. Here, we use the Berkeley Environmental Air‐quality and CO 2 Network (BEACO 2 N) to study CO 2 and air pollutant emissions from an oil refinery in the city of Richmond, CA. We identify 266 plumes crossing one or more sites in the BEACO 2 N network during 2022–2023 as having a source at the refinery and quantify CO 2 emissions using the Gaussian plume model. The refinery is modeled as two point sources, and total CO 2 emissions are found to be 61.3 ± 6.3 kg s −1 , in close agreement with the EPA Facility Level Information on GreenHouse gases Tool inventory and Carbon Mapper measurements. Additionally, plume composition was found to vary, with CO/CO 2 enhancement ratios ranging from 0 to 5 ppb/ppm. Taking the average CO/CO 2 ratio, CO emissions are estimated to be roughly 3,000 mt, a sizable amount compared to the city's estimated non‐refinery CO emissions of 6,800 mt. In addition, we show that dense monitoring networks provide a unique resource for point source emissions quantification with broad application to plumes of varying size and composition, and recommendations are laid out for future applications.