Ni Zhu

Ni Zhu

Auto-generated profile, based on publicly available information

Ni Zhu

Via Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 April 2018 in Journal of Infection and Chemotherapy
Verified
Journal Article
Closed access
YLYunchun Luo
Yunchun Luo
WYWen Yi
Wen Yi
YYYuzhou Yao
Yuzhou Yao
NZNi Zhu
Ni Zhu
PQPengfei Qin
Pengfei Qin

3 April 2020 in Environmental Science: Water Research & Technology
Verified
Journal Article
Closed access
PDF file
NZNi Zhu
Ni Zhu
KMKris Mapili
Kris Mapili
HMHaniyyah Majeed
Haniyyah Majeed
APAmy Pruden
Amy Pruden
MEMarc Edwards
Marc Edwards
Changing chemistry and microbiology of reclaimed water as it is conveyed via reclaimed water distribution systems (RWDSs) can influence water quality at the point of use. Two simulated RWDSs comprised of 0.32 cm tubes (“Tube” RWDSs) and 10 cm diameter pipes (“Pipe” RWDSs) were designed to investigate how extremes in water age (32 min versus 5 d) and surface area to volume ratio (6.25 cm−1versus 0.20 cm−1) affect the potential for sediment accumulation, disinfectant decay, and chemical and microbial water quality under controlled treatment conditions. Effluent from a conventional municipal wastewater treatment plant was breakpoint chlorinated and treated with and without biological filtration, followed by three disinfectant conditions: no residual, 4 mg L−1 chlorine or 4 mg L−1 chloramine. After three years of operation, accumulated sediment occupied 0.32–3.2% of the total volume of the first pipe segment. The unfiltered chlorine condition had an order of magnitude less influent turbidity and sediment accumulation than conditions with no residual or chloramine, resulting in lower levels of biological activity and slower depletion of disinfectants and dissolved oxygen. The sediment in pipes receiving chloraminated water was highly biologically active and created a high disinfectant demand due to nitrification. In contrast, the tube RWDSs did not accumulate sediment. The Tube rigs with chloramine and no residual had heavy bio-foulant growth, which resulted in rapid depletion of chloramine. Biofilm was the main source of disinfectant demand in the chlorine tubes. An improved holistic understanding of RWDSs chemistry, biology and operation will help achieve desired water qualities at the point of use.

16 September 2020 in Environmental Science: Water Research & Technology
Verified
Journal Article
Closed access
PDF file
NZNi Zhu
Ni Zhu
SGSudeshna Ghosh
Sudeshna Ghosh
LSLaurel Strom
Laurel Strom
APAmy Pruden
Amy Pruden
MEMarc Edwards
Marc Edwards
The distinct characteristics of reclaimed versus potable water have important implications for design and operation of reclaimed water distribution systems (RWDSs). Here we operated six simulated RWDSs in parallel to determine the effects of feed water treatment (with and without biologically-active carbon (BAC) filtration) and residual disinfectants (chlorine, chloramine, or no residual) on the distributed water quality. Following a six-month acclimation period, the experimental conditions were implemented over 2 years of operation, with a temperature regime of 14 °C → 22 °C → 30 °C → 22 °C → 14 °C imposed to simulate seasonal variation. Comprehensive water chemistry profiling and microbial sampling were conducted over a range of water ages (0 d, 1 d, 2.5 d and 5 d) along the RWDSs at each temperature phase. When ≥22 °C, RWDSs became more vulnerable to deterioration of water quality due to nitrification, as evidenced by accelerated chloramine decay and increased relative abundance of nitrifier genera and functional genes. Contrary to conventional experience in potable water distribution, chlorine generally became more persistent than chloramine from the first 22 °C phase onwards. Enhanced persistence of chlorine was accompanied by increased biological stability (i.e., lower cell counts and reduced dissolved oxygen demand). BAC filtration initially improved water quality (i.e., lower total organic carbon and biomass, longer persistence of disinfectants), but benefits diminished over long term distribution system operation. Taxonomic and functional metagenomic profiles revealed that chlorine had the strongest selective effect compared to both chloramine and no residual, particularly for the unfiltered condition. The long-term operation strategy employed here enabled evaluation of distribution system management practices and their interactive effects as the RWDSs experienced temperature shifts and aged.