İrFan Uckan

İrFan Uckan

Auto-generated profile, based on publicly available information

İrFan Uckan

YÜZÜNCÜ YIL ÜNİVERSİTESİ, MÜHENDİSLİK FAKÜLTESİ

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2014 in International Journal of Green Energy
Verified
Journal Article
Closed access
IUİrFan Uçkan
İrFan Uçkan
TYTuncay Yılmaz
Tuncay Yılmaz
EHErtaç Hürdoğan
Ertaç Hürdoğan
OBOrhan Büyükalaca
Orhan Büyükalaca
This work presents mathematical equations derived from Artificial Neural Networks (ANNs) for the estimation of dry bulb temperature and specific humidity at the outlet of a desiccant wheel to predict useful data for designers and engineers. The neural network model comprises five inputs and two output neurons that define the outlet conditions (dry bulb temperature and specific humidity) of a desiccant wheel. The results obtained by the ANN model are compared with the actual data by using input variables. The results show that the mean absolute percentage errors for dry bulb temperature and specific humidity are found to be 0.80% and 1.56% respectively; and the correlation coefficient (R) values obtained are approximately 0.986 for both output variables. The root mean square errors, which is another significant point in this study, are found to be 0.54% and 0.18% for dry bulb temperature and specific humidity respectively.

17 November 2023 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
IUİrFan Uçkan
İrFan Uçkan
AYAhmet Yakın
Ahmet Yakın
RBRasim Behçet
Rasim Behçet

29 May 2020 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
Verified
Journal Article
Closed access
IUİrfan Uçkan
İrfan Uçkan
AYAli Abdullah Yousif
Ali Abdullah Yousif
A single-effect absorption cooling system was planned and simulated appropriate to a hot and dry climate, and optimization was made accordingly in the present study. TRNSYS software is a very comprehensive program that includes much equipment in its subprograms. For this reason, solar collectors, cooling tower, auxiliary heater, and storage tank used in this study are modeled in this software. The designed cooling system is considered as a market that has a cooling need of 35 kW and has a space of 275 m2. It was examined in this study that how the performance of a single-effect LiBr-H2O absorption cooling system was affected by three different kinds of solar collectors such as flat plate collector (FPC), Non-tracking concentrating parabolic solar collector (XCPC), and evacuated tube collector (ETC). It was also evaluated that how different criteria such as solar fraction, hot water tank temperature and tank volume, collector area, and collector type affected system performance. In the study, it was noticed that collector area had an important effect on the collector efficiency, heater power and hot water tank temperature. It was found that minimum collector area for XCPC, ETC and FPC collectors were approximately 100 m2, 125 m2 and 150 m2, respectively. Also, depending on the change in the tank volume, significant changes occurred in the tank temperature. The hot water tank volume was raised from 0.5 m3 to 6 m3 for XCPC, ETC and FPC collectors, the upper hot water tank temperature decreased about 15°C, 11°C and 8°C, respectively. In conclusion, it has been observed that XCPC collectors perform better to improve system performance compared to other collectors used.

24 May 2024 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
IUİrFan Uçkan
İrFan Uçkan
AYAhmet Yakın
Ahmet Yakın
BCBeyza Cabir
Beyza Cabir

24 January 2022 in Environmental Science and Pollution Research
Verified
Journal Article
Closed access
PDF file
IUİrFan Uçkan
İrFan Uçkan
KKKameran Mohammed Khudhur
Kameran Mohammed Khudhur

26 March 2018 in International Journal of Green Energy
Verified
Journal Article
Closed access
IUİrFan Uckan
İrFan Uckan
KKKameran M Khudhur
Kameran M Khudhur
In this study, 54 empirical models including 22 new models were used to estimate the global solar radiation on horizontal surface. The data were collected in Dohuk cities in the northern Iraq. The evaluated models are based on sunshine duration, air temperature, cloud cover, and other meteorological parameters. In the investigated region, the statistical error indicators value for all empirical models of R, R2, mean absolute bias error, root mean square error, mean absolute percentage error, Nash–Sutcliffe equation, and t-test value were low and within an acceptable range. The results of Model 49 based on the other meteorological parameters which is newly developed model with equation of had the most appropriate result with a value of R2 (0.9942) in the 54 empirical models. Besides, 22 new equation models are produced based on sunshine hours, air temperature, and other meteorological parameters. The best accuracy among the new equation was observed in Model 49. Furthermore, the Models 34, 12, and 25 based on cloud cover, sunshine hour, and air temperature in terms of data accuracy were ranked, respectively.