Buju Gong

Buju Gong

Auto-generated profile, based on publicly available information

Buju Gong

Air Pollution Engineering Division, Atmospheric Environmental Research Department, National Institute of Environmental Research, Hwangyeong-ro 42, Seo-gu, Incheon 22689, Republic of Korea

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
JRJoon Young Roh
Joon Young Roh
SKSeongmin Kang
Seongmin Kang
BGBuju Gong
Buju Gong
KLKyungwon Lee
Kyungwon Lee
Eui-Chan JeonEui-Chan Jeon
Eui-Chan Jeon
In this study, the emission factor and concentration of ammonia from industrial waste incineration facilities were analyzed through actual measurements. The ammonia emission factor was calculated and the difference in ammonia emission factor for each type of incineration was confirmed through the Mann–Whitney U test. As a result of analyzing 279 samples, the NH3 emission factor of the SNCR facility of stoker types was 0.012 kgNH3/ton, and the NH3 emission factor of the SNCR facility of the rotary kiln methods was 0.014 kgNH3/ton. Additionally, the NH3 emission factor of this study was higher than the NH3 emission factor (0.003 kgNH3/ton) suggested by Kang’s study (0.009 kgNH3/ton) and EMEP/EEA (2006). There is a need to develop an NH3 emission factor that takes into account the characteristics of Korea, since it is largely different from the NH3 emission factor of EMEP/EEA. As a result of statistical analysis of the stoker type and the rotary kiln method, the null hypothesis that there is no difference between each type was adopted (p-value > 0.05), indicating that there was no statistical difference in the ammonia emission factors of the stoker type and the rotary kiln type.

30 September 2018 in Journal of Odor and Indoor Environment
Verified
Journal Article
Closed access
JKJong Hyeon Kim
Jong Hyeon Kim
NRNational Institute of Environmental Research
National Institute of Environmental Research
NKNa Rae Kim
Na Rae Kim
GJGang Nam Jo
Gang Nam Jo
JPJeong Min Park
Jeong Min Park
BGBu Ju Gong
Bu Ju Gong

31 December 2020 in Journal of Odor and Indoor Environment
Verified
Journal Article
Closed access
BGBuju Gong
Buju Gong
JKJonghyeon Kim
Jonghyeon Kim
DODuhyun Oh
Duhyun Oh
JYJungwung Yoo
Jungwung Yoo
EWEunji Woo
Eunji Woo
JPJungmin Park
Jungmin Park

31 December 2019 in Journal of Odor and Indoor Environment
Verified
Journal Article
Closed access
NRNational Institute of Environmental Research
National Institute of Environmental Research
BGBuju Gong
Buju Gong
JKJonghyeon Kim
Jonghyeon Kim
GLGyeongmi Lim
Gyeongmi Lim
EWEunji Woo
Eunji Woo
YKYoungwoo Kim
Youngwoo Kim

30 December 2022 in Journal of Odor and Indoor Environment
Verified
Journal Article
Closed access
KLKyungwon Lee
Kyungwon Lee
KKKeehong Kim
Keehong Kim
GPGyutae Park
Gyutae Park
JPJungmin Park
Jungmin Park
BGBuju Gong
Buju Gong

25 August 2025 in Atmosphere
Verified
Journal Article
Open access
PDF file
HGHannui Gil
Hannui Gil
BGBuju Gong
Buju Gong
DKDae Il Kang
Dae Il Kang
HJHeeji Jo
Heeji Jo
KKKeehong Kim
Keehong Kim
JEJeong Ji Eun
Jeong Ji Eun
Asphalt concrete (ascon) manufacturing facilities in South Korea are located near urban areas and emit various air pollutants, including polycyclic aromatic hydrocarbons (PAHs) such as benzo(a)pyrene (BaP), a Group 1 carcinogen. However, few measurement-based studies exist in Korea, and no domestic BaP emission factor has been established, making its effective management difficult. In this study, PAH concentrations emitted from stacks were measured using gas chromatography/mass spectrometry at 29 facilities located near densely populated areas. BaP was detected at all facilities, and emission factors were calculated based on the ascon materials and dryer fuel types. The calculated emission factors were found to be 31 to 6230 times higher than the AP-42 standards provided by the US Environmental Protection Agency. This discrepancy likely arises from differences between processes and fuel characteristics. Using the California Puff model, BaP concentrations in the near area were predicted, corresponding to as much as 30% of the US National Ambient Air Quality Standards. These findings indicate a potentially significant environmental health risk in nearby communities. The findings of this study can serve as foundational data for formulating policies and providing institutional support aimed at managing emissions from ascon manufacturing facilities in Korea.